SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-L-P-F02L"

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/4, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: w/o Lead Wire, Bracket: Bracket C, Operation Manual: -

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket:

Operating pressure P (MPa) P 0.7 MPa MTS 4.

The amount of air requirement of rotary actuator = 0.06 x V x (P/0.1)/t l/min(ANR) V : Inner volume = cm3 P : Absolute pressure = {Operating pressure (MPa) + 0.1} t : Operating time = s CRB2 CRBU2 CRB1 Calculate the required air volume separately for the linear motion part and the rotary motion part.

Contents Bore size (mm) CQ2A32-L-PS CQ2A40-L-PS CQ2A50-L-PS CQ2A63-L-PS CQ2A80-L-PS 32 40 50 63 80 100 CQ2A32-L-PS CQ2A40-L-PS CQ2A50-L-PS CQ2A63-L-PS CQ2A80-L-PS CQ2A100-L-PS !4 !5 !6 Set of left nos. !4, !5, !6. Rod seal Piston seal NBR Tube gasket CQ2A100-L-PS Seal kit includes !4, !5, !6. Order the seal kit, based on each bore size.

MHC2, MHCA2, MHCM2 F L F MHC2-6D/MHCA2-6D MHC2-6S/MHCA2-6S MHCM2-7S Pressure 0.6MPa 4 4 2 Pressure 0.6MPa 0.5 Pressure 0.6MPa Gripping force N Gripping force N Gripping force N 3 3 0.4 0.5 0.5 1 2 2 0.3 0.4 0.4 0.2 1 1 0.3 0 30 20 10 0 30 20 10 0 30 20 10 Gripping point L mm Gripping point L mm Gripping point L mm 2 Series MHC2/MHCA2/MHCM2 Confirmation of inertial moment of attachment Step

Note 3) Bowl assembly for AL30 to AL60 comes with a bowl guard (steel band material). 52 AL10 to 60 Dimensions AL10 AL20 L D Bracket (option) G F Port size K M A Port size C B R C J H OUT OUT IN OUT OUT IN B R P Min. clearance for maintenance Min. clearance for maintenance A AL50, 60 AL30, 40 L D D L Port size Bracket (option) Bracket (option) G F G F Port size M K M K E J C B R C B R H

P EA EB 3 position pressure center A B 5 EB P EA 3 position double check A B 6 EB P EA For the solenoid valve specifications and dimensions, please refer to VQC catalog (ES11-80). Please refer to page 13 for Series EX250 single SI unit dimensions. For details of the Series EX250 SI unit, please refer to the technical instruction manual.

Tie-rod Type Low Pressure Hydraulic Cylinder Double Acting/Double Rod Series CHAW 40, 50, 63, 80, 100, 125, 160 3.5MPa How to Order Bore size 40 50 63 80 100 125 160 40mm 50mm 63mm 80mm 100mm 125mm 160mm Aluminum tube Steel tube Tube material Aluminum alloy Steel tube Nil F Without auto switch Nil Auto switch type CHAW 40 100 L L With Auto Switch Select applicable auto switch models from

L D-M9P (Example) Nil Lead wire length 0.5 m 3 m L 5 m Z Note 1) Applicable auto switch with 5 m lead wire Z Reed switch: None Solid state switch: Manufactured upon receipt of order as standard. Note 2) To designate solid state switches with flexible specifications, add -61 after the lead wire length. Oil resistant flexible cab-tire cord is used for D-M9 as standard.

Speed Controller for Low Speed Operation Speed controller with One-touch fitting (resin body) Connecting tube Page Port threads AS-FM Elbow type R Metric size P.1 New New NPT Inch size Universal type R Metric size P.1 New New NPT Inch size In-line type New New Metric size Inch size P.9 Speed controller (metal body) Cylinder side Tube side AS-M R R Elbow type P.7 NPT NPT Dual speed controller