LC3F212-5A3 Applicable directional control driver LZ3-A3LZ5-A5LC3F212-5A5 Dimensions CN2 control terminal 38.5 31.6 3.7 8 M3 x 0.5 For protection grounding terminal mounting Protection grounding terminal 8 5.5 78.6 94 92 86 2-3.6 For main body mounting 28.5 57 53.5 (3.5) Protection grounding terminal related components Cross recessed bind screw M3 x 4 1 pc. (2) Spring washer Nominal 3 1 pc
Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.
Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.
[V] A B C 0-101 kPa 0 -101 kPa 10.1 kPa -100100 kPa -100 kPa 100 kPa 01 MPa 0 1 MPa -0.1 MPa 0500 kPa 0 500 kPa -50 kPa -13No.PS-OMG0005CN-E PSE5601 PSE56N01 02 N02 PSE56-C01 A B PSE56-01 8.2 R1/8 PSE56-02 12 R1/4 PSE56-N01 9.2 NPT1/8 PSE56-N02 12.2 NPT1/4 PSE56-A2 PSE56-C01 Rc1/8 PSE56-A2 15.5 URJ1/4 PSE56-B2 9.5 TSJ1/4 PSE56-B2 ZS-31-X D E F G H I ZS-31-X188 20 9 R1/8 R1/8 14 1.5
Note) Metric size Inch size 23 04 06 08 10 12 Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT Port size AS-FE KE 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 3.2 4 6 8 10 12 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 N AS-FG AS-FG AS-FP AS-FM Note) For applicable tubing O.D. selection, refer to the Model on page 542. Use 1/8" tube.
Port size N M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 Needle Valve/Flow Characteristics AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm2) Effective area (mm2) Effective
Note) Metric size Inch size 23 04 06 08 10 12 Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT Port size AS-FE 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 3.2 4 6 8 10 12 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 KE N AS-FG AS-FG AS-FP Note) For applicable tubing O.D. selection, refer to the Model on page 680. Use 1/8" tube.
Max. operating pressure Symbol 16 23 40 VCHR 1.6 mm 0.7 MPa Without sub-plate (with mounting screw M3 x 8L, 2 pcs.)
TMH M5 Port size ASD M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Applicable tubing O.D. Note) Type 01 02 03 04 Inch size Metric size Elbow Universal 2 3 1/8" AS 23 01 3.2 03 05 07 09 11 13 04 06 08 10 12 4 5/32" 6 3/16" Control AS-FE U10/32 N01 N02 N03 N04 8 1/4" Meter-out Meter-in 0 1 10 5/16" Made to Order Refer to the below for details.
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Measurement mode Power is supplied Installation Press the SET button between 3 and 5 seconds Mounting by panel mount adapter Fix the panel mount adapter to the Controller with the set screws M3 x 8L (2 pcs.) as attached.