1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
Standard Strokes Bore sizes (mm) Standard strokes (mm) 20 & 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 32 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75 40, 50, 63, 80, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Made to Order Pages 22 to 24 Manufacture of Intermediate Stroke Cylinders Hydraulic Fluid Compatibility Intermediate strokes in 5mm increments can be manufactured by installing spacers
N S + Stroke H B ZZ + Stroke Stroke range Bore size (mm) I J K M B D C E KA GA GB H 40 50 63 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 10 14 14 45 55 68 21 26 32 36 46 53 34.5 40 46.5 40 45 50 46 55 66 59 71 82 23.5 28 34.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) MM XA XL Y ZZ MA MB MC N P S 40 50 63 M6 x 1.0 M8 x 1.25 M8 x 1.25 12 16 16 6 6 6 9.5 12.5 15 178 195 221 18
Series CBQ2 Allowable Kinetic Energy Allowable Rod End Lateral Load 0.5MPa 0.4MPa With rubber bumper With auto switch (lateral resistance) 200 100 100 50 50 40 30 Allowable lateral load W (N) 63 20 Load weight kg 50 10 63 40 32 10 5 4 3 50 5 2 40 1 0 10 20 30 40 50 60 70 80 90 100 32 Stroke St (mm) 1 50 100 200 500 300 Maximum speed mm/s (Mounting orientation: Horizontal) W
7. * The seal kit includes 2 cushion seals, 1 rod seal, 1 piston seal, and 2 tube gaskets. 1.7-27 Series MBlQ Basic/(B) G G Cushion valve W V Port 2-Rc(PT)P MM D E MB Effective thread 2 X 4-J lC lB MA A K F N N S + Stroke H ZZ + Stroke (mm) Stroke range Width across flats Bore (mm) Effective thread length A D Ee11 F N G P MA S MB V J W K H ZZ MM lC lB 32 40 50 63 80 100 22 30 35 35 40 40
-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.
DC AC, DC 60 40 1 80 60 10(1) 40 60 60 40 Maximum Minimum 10 5(2) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E, N, P etc. in parentheses are option symbols.
(-B is not necessary) Note 3) Specify -K for wiring specification for cases below. (Except L kit) All single wiring Single and double mixed wiring. When there are stations which do not require wiring (e.g. individual SUP spacer), specify the wiring specification in the manifold specification so that the number of solenoids is the maximum number of solenoids or less.
Note 3) This data is considered typical but not guaranteed. 10Leakage test result 100 5 10 Time [min] e e a a l l k k w w 2 a a 1 O-ring seals separate vacuum and atmosphere. Employs a magnetically coupled rodless cylinder with no air leakage from moving parts. o o g g L L e e Static O-ring seals are used for all the seals between vacuum and atmosphere.
ZSP ISl SET ALM. 20 kgf K P M b ZSM + _ PFl UNIT P.SET IFl 3.6-4
B L A C K L E A D W I R E Connects with minus (-) side of the direct current to actuate the switch.
When the rotational axis and load center of Rectangular parallelepiped) Position of rotational axis: Perpendicular to the plate through the center of gravity gravity are not consistent L 2 r I = K + mL K: Moment of inertia around a b the load center of gravity 2 2 b a + 2 r I = m 12 4.Round plate K = m2 9. Gear transmission 4.
In-line type How to Order JIS Symbol 1F 12 K 400 AS Option Body size Nil K N None Hexagonal lock nut Electroless nickel plated If more than one option is required, write option part numbers in the order of K, N. M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.
UJ I 2-Forled \bBion DIMENSIONS A B c o E F G H J K M P R s T 1.57 (40) 2.52 (64) 2.20 (56) 1.77 (45) 4.80 (1221 1.97 {50} 0.98 (25) 1 . 1 0 (28) 0.51 (13) 4.45 (113) ?
H IDX-OM-W093 7.3 Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J M N O L K H mm A B C D E F G H J K L M N O P IDF60 R1 307 745 605 161 405 681 71 330 704 355 126 46 12. 94 5 IDF70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDF80 R2 438 957 863 169 480 958 219 78 100 11. 0 463 916 485 170 IDF90 13 IDF80 IDF90 mm IDF60 745 957 () () 704 916 () 355
UJ I 2-Forled \bBion DIMENSIONS A B c o E F G H J K M P R s T 1.57 (40) 2.52 (64) 2.20 (56) 1.77 (45) 4.80 (1221 1.97 {50} 0.98 (25) 1 . 1 0 (28) 0.51 (13) 4.45 (113) ?
flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
L 5 4.4 [mm] L M 32 40 9 M6 4.3 16 4-3. A 4.4 4.4 5 B C E A D F 4.5 32 5.7 40 4.8 4-4. 4.5 4.6 (POSI LOCK) ISEL(MECHALOCK) NBK(Clamp Lock) 32 PSL-K-12 MA-12-26 CLH-1218 40 PSL-K-14 MA-14-28 CLH-1423 17 4-5. 4.6 4-6. 4.74.7 2 4.7 32 Rc1/8 Rc1/8 M50.8 40 Rc1/8 Rc1/8 M50.8 4.7 , A) , , , B) , ,1.52 18 5. 5. 5. 5. ,, 5-1.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com