Pressure loss in air blow is significantly reduced with an effective sectional area as large as 30 mm2. Gun, a large reduction in air consumption can be attained. un, a large reduction in air consumption can be attained. With an SMC Blow Gun, a large reduction in air consumption can be attained. With an SMC Blow Gun, a large reduction in air consumption can be attained.
Operation of actuator When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation. 7.
(Reduce power consumption by up to 20%.)
Install an aftercooler, air dryer or drain catch before the filter and take appropriate measures. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment. Therefore, take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer or water separator. 4.
Max. diameter of an electric cord usable for bulb gland is shown as below. Cable gland Max. diameter of an electric cord 20a 20b 20c 12 13 15 How to Order 3. Terminal thread type is M4. ISG 1 03 1 0 0 W Mounting/Piping Caution Multipurpose pressure switch 1. Mounting is possible in either horizontal or vertical orientations.
It is suitable for use in cases where "water must be removed, but the air does not have to be as dry as when an air dryer is used" or "an air dryer cannot be used because an electric power supply is not available".
Contact P/A when using the regulator between a solenoid valve and an actuator.
Spatter cover Spatter cover Plug Prevention of tube releasing unconformity due to an inside intrusion or adhesion of the spatter. Prevention of tube releasing unconformity due to an inside intrusion or adhesion of the spatter. P. 5 KR P. 5 KRC1 KRP P. 5 Use to plug unused One-touch fittings.
If foreign matter is adhering to the parts, perform an appropriate procedure, such as blowing with air or cleaning with neutral detergent. Closing the valve: Turn 90 counterclockwise from the open state to the original state to close the valve. Perform an eletrical operation at the position where the valve is closed.
They are suited to operate large bore cylinders as well as to simultaneously operate multiple cylinders and suspend their operation. Thus they can be used in the same way as the conventional air-hydro units. Refer to Air-hydro Unit pages in Best Pneumatics Vol. 10 for further information on air-hydro.
Since Series CHQB does not have an air release plug, release air from other components (e.g. from piping, etc.) as well. 6. When mounting the cylinder body with mounting bolts, use the tightening torques in the table at right as a guide.
], ISA3-G: [50], ISA3-H: [50] ISA3-F: [3], ISA3-G: [20], ISA3-H: [20] Display Thank you for purchasing an SMC ISA3-#L series Gap Checker.
The residual leakage voltage must be kept as follows: With a DC coil, 3% of the rated voltage or below With an AC coil, 8% of the rated voltage or below. 0.2 to 0.33 mm2 Max. cover O.D. : 1.7mm 3.5-2 Common Precautions Series CV Applicable series: CVM5, CVM3, MVGQ Light and Surge Voltage Suppressor Plug Connector Caution Caution q Connector installation and removal OTo install the connector
an IODD File To set an IO-Link Device by using IO-Link Device Tool, an IODD file for each device must be imported.
110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 1/8, 1/4, 3/8 1/4, 3/8 1/2 3/8, 1/2 3/4 1/2, 3/4 1 3/4, 1 1, 11/2 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 24
Load mass Allowable moment MY1H/m MY1H/M MY1H/M MY1H/M 2 1 3 40 50 50 40 50 40 50 4 40 5 30 30 30 30 20 20 20 20 MY1H40 MY1H32 MY1H40 MY1H32 10 10 10 MY1H40 MY1H40 MY1H40 MY1H40 MY1H32 MY1H40 MY1H32 MY1H32 MY1H32 MY1H32 5 4 MY1H25 MY1H25 10 MY1H40 MY1H40 Load mass kg Moment Nm Moment Nm Moment Nm 5 4 5 4 MY1H32 MY1H32 MY1H25 MY1H25 MY1H25 3 MY1H25 MY1H25 MY1H20 MY1H20 3 3 2 MY1H25 MY1H25
100 P = 0.5 MPa Load weight m(kg) Load weight m(kg) D40 50 100 Larger than 75st 50st 25st Larger than 50st 30 20 -X 50 40 25, 50st 10 30 205 4 3 2 20 Data 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg