An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.
In the ON condition an indicator LED will show, and any connected load will be powered. In the OFF condition, there will be no indicator LED and no power supplied to the load. An output showing such behavior is called switch output.
an external temperature sensor is displayed.
Do not use an open tank. Ensure that the INLET and OUTLET for circulating fluid is connected correctly. If any valves are used ensure that they do not restrict the flow, otherwise low flow my cause an alarm. 3.5 Handling Transport Thermo-con with both handles.
An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. d. When used in an interlock circuit, dual interlock such as mechanical protection is necessary in case of accident. Periodical inspection is also necessary to confirm proper operation.
Exterior dimensions C D XMA Series Angle Valve Fd Fn Fc C Fc L1 KF Flange K Flange CF Flange ( K ) ( K F ) ( C F ) L2 H B G A A Unit:mm Model n Fd Fc H P.C.D L1 L2 XMA-16 40 103 38 1 30 34 17 40 P.C.D 27 6x4.4 XMA-25 50 113 48 1 40 26 39 XMA-40 65 158 66 2 55 70 41 63 P.C.D. 58.7 6x6.6 XMA-50 70 170 79 2 75 52 68 XMA-63 88 196 100 3 87 95 114 70 69 P.C.D. 92.1 8x8.4 XMA-80 90 235 117 3 114
Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter rate of change of 10% or less. At higher temperatures the outside diameter rate of change may exceed 10% within the minimum bending radius.
This may also have an adverse effect on the peripheral equipment in proximity. Should a valve be continuously energized for long periods, or its daily energized state exceeds its non energized state, please use an energy saving type valve with DC specifications.
Otherwise, an injury or failure can result. Disassembly prohibited Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Please check the specifications before use. Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.
Event When an error occurs, an event with the same content as DetailedDeviceStatus (Section 3.3.3) will occur. Table 7-1.
Note 3) For the inch-size One-touch fittings, refer to page 4-14-40.
Nil C 0.4 to 4 l/min 1.8 to 20 l/min 4 to 40 l/min 04 20 40 The cable and connector are shipped unassembled.
40 40 50,63 40 40 40 32 32 32 32 32 32 11 (5) 10 20 30 50 40 51 100 101 300 200 11 (5) 10 20 30 50 40 51 100 101 300 200 Stroke (mm) Stroke (mm) MGPL80/100, MGPA80/100 MGPL80/100, MGPA80/100 110 (50) 110 (50) 100 100 100 80 80 80 Load mass m lbs (kg) Load mass m lbs (kg) 100 100 80 80 100 22 (10) 22 (10) 80 11 (5) 10 100 20 29 30 5051 300 200 11 (5) 10 100 20 29 30 50 51 300 200 Stroke (
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.
-40 Air consumption -40 40 -40 40 Suction flow rate Suction flow rate -20 20 -20 -20 20 -20 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0 10 20 30 40 50 5 10 15 20 25 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0 Supply pressure (MPa) Suction flow rate (l/min(ANR)) Supply pressure (MPa) Suction flow rate (l/min(ANR)) How to Read Flow Characteristics Graph The flow rate characteristics indicate the relationship
Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St.
AXT100-DR7 L dimension Select L dimension from the table below and enter an applicable symbol.
Manifold block assembly number differs according to an attached lead wire assembly based on the connector specification (Single, Double). Select an appropriate part number from among the manifold block assembly numbers shown below.
Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause a malfunction of pneumatic equipment such as valves.
Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause a malfunction of pneumatic equipment such as valves.