Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Symmetric mounting Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
The plug (M5 x 0.8) in the standard dimensions becomes a relief port. Relief port size M5 x 0.8 Piston speed 50 to 400 mm/s Mounting Basic style, Axial foot style, Rod side flange style Head side flange style Auto switch can be mounted.
The plug (M5 x 0.8) in the standard dimensions becomes a relief port. Relief port size M5 x 0.8 Piston speed 50 to 400 mm/s Mounting Basic style, Axial foot style, Rod side flange style Head side flange style Auto switch can be mounted.
The plug (M5 x 0.8) in the standard dimensions becomes a relief port. Relief port size M5 x 0.8 Piston speed 50 to 400 mm/s Mounting Basic style, Axial foot style, Rod side flange style Head side flange style Auto switch can be mounted.
Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.
Applicable bore (mm) d H1 B1 C1 4T counterbore A' 6 10 16 20 25 32 NTP-006 NTP-010 NTJ-015A NT-015A NT-02 NT-03 M3 x 0.5 1.8 2.4 4 5 5 6 5.5 7 8 10 13 17 6.4 8.1 9.2 11.5 15.0 19.6 S + Stroke Auto switch M4 x 0.7 Z + Stroke M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 Bore size (mm) A A' B C D E GA GB H J K L MM NN P Q QA 6 10 16 20 25 32 7 10 11 12 15.5 19.5 10 10 11.5 12.5 13 12.5 12.5 14 18
: M5 x 0.8 0XY: M6 x 1.0 771
After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/4 turn for a port size of M3 x 0.5 or 1/6 turn for a port size of M5 x 0.8. For elbow type fittings, tighten an additional 1/2 turn for a port size of M3 x 0.5 or 1/3 turn for a port size of M5 x 0.8 if gaskets are mounted in two places.
This product cannot be used to hold a stop position for an extended period of time. Pilot check valves and actuators are not guaranteed for zero air leakage. Therefore, it is sometimes not possible to hold a stop position for an extended period of time. In the event that holding for an extended time is necessary, a mechanical means for holding should be devised. 3.
x 0.8 thread depth 4 (Piping port) OUT IN Steel balls 12 Series CXSJ Dimensions: 15 to 32 Standard Piping U Q R T ZZ + Stroke Stroke J K SS + Stroke 1 D B M L Z I 1 G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-Rc1/8 thread depth 5 SS T Bore size (mm) 2 2-4.3 through
hole & Double end tapped): MQQTB 10, 16, 20 H effective thread depth C 2-M5 x 0.8 2 x 4-OA effective depth RA 2 x 4-OB Depth of counterbore RB F Q Y I 4-N through 0.2 D E M L B + Stroke K 0.2 A + Stroke M E 25, 30, 40 H effective thread depth C 2-Rc1/8 (NPT1/8, G1/8) F Q Y 2 x 4-OB Depth of counterbore RB 2 x 4-OA effective depth RA J I 4-N through 0.2 D W E M K L B + Stroke 0.2 A + Stroke
L1 L2 A (2) L3 H (1) T2 T1 D1 D2 Model ASR ASQ AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS120-M5 M5 x 0.8 M5 x 0.8 8 10 28.3 10.3 9 9 25 22.2 25.5 AS120-U10/32 10-32UNF 10-32UNF AS220-01 30.5 13.2 14.3 14.6 32.4 27.4 12 (12.7) 18 35.5 1/8 1/8 AS220-02 35.3 17.5 18 19.5 34.8 29.8 17 (17.5) 27.2 40.3 1/4 1/4 AS320-03 40.8 19.7 22.5 24.3 40.6 35.6 19 30 45.8 3/8 3/8 AS420
P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 F N T Same side of A port S C6 6 cassette Valve stations Type S42 (Solenoids on the same side of A port) 01 1 station 20 20 stations P port: Rc 1/8 R port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH How to Order Type 21: Body ported (A port top ported) Applicable solenoid valve VK332--M5 VK332--01 Applicable blanking plate assembly VK300
This product should not be used as a stopper.
D2 M1 L1 L2 T M5 type H (width across flats) Applicable tubing O.D. d A A4 D1 L3 D2 M1 L1 T L2 Model Weight (g) Note 2) Tubing O.D. d T H D1 D2 L1 L2 L3 M1 L4 Max.
x 0.8, NPTF 1/8, M5 x 0.8 Port size R 1/8, M5 x 0.8 NPTF 1/8, M5 x 0.8 ZX ejector mounted type: M5 x 0.8 Enclosure IP40 Note 1) Instant pressure supply of 0.5 MPa has no influence on the switch.
L1 L2 A(2) L3 H(1) T2 T1 D1 D2 Model AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS1200-M5 M5 x 0.8 M5 x 0.8 25.5 8 10 28.3 10.3 9 9 25 22.2 AS1200-U10/32 10-32 UNF 10-32 UNF AS220-01 27.4 32.4 14.6 14.3 14.1 31.4 36.4 18 12 (12.7) 1/8 1/8 AS220-02 29.8 34.8 19.5 18 18 35.8 40.8 27.2 17 (17.5) 1/4 1/4 AS320-03 35.6 40.6 24.3 22.5 20.8 41.9 46.9 30 19 3/8 3/8 AS420-04 42.4
Molded-case circuit breaker (Note 1, 3) Fuse Frame, rated current Magnetic contactor Driver Voltage Voltage AC [V] Class Current Power factor Power factor (Note 2) [A] AC [V] Improving reactor is Improving reactor is not used used LECSS2-T5 30 A frame 5 A S-N10 10 LECSS2-T7 LECSS2-T8 30 A frame 10 A 30 A frame 5 A 15 Mitsubishi 240 T 300 Electric Corporation LECSS2-T9 30 A frame 15 A 30 A