When the IDFA100F-40 is provided with options C, R and V the part number will be IDFA100F-40-CRV. 100 F 40 NIL IDFA C K Size R Air compressor size Note) 100kW 125kW 150kW Note) The value is referential. Confirm the capability of the compressor used.
Positioning Mode: Minimum actuator travel distance of 1[m]. 28 - Recommended Parameter Values [LEY] LEY25/LEYG25 LEY25D/LEYG25D LEY32/LEYG32 LEY32D/LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para. No Initial value Recommended value Number of command input pulses per revolution *3. PA05 100 100 Electronic gear numerator *3.
Perform maintenance for the product periodically. 4 Model Indication Method E-MY2 C 16 100 TA N A M M9B General 3 positions 5 positions General Number of auto switches Guide Type C Cam follower guide type H Linear guide single axis type Auto switch HT Linear guide double axis type Cable length Nil Controller integrated type 1m M Nominal size Controller separated type 3m L 16 5m Z 25 Positioning
Double acting, Single rod Double acting, Double rod CE1 50 63 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 CE2 80 100 ML2B C J G5-S CHQB CHQWB CV MVGQ CC For details, refer to the catalog CAT. E111.
Double acting, Single rod Double acting, Double rod CE1 50 63 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 CE2 80 100 ML2B C J G5-S CHQB CHQWB CV MVGQ CC For details, refer to the catalog CAT. E111.
Auto Switch Proper Mounting Position (Detection at Stroke End) Electrical entry direction: Inward Electrical entry direction: Outward D B A C B D-Z7Z8, D-Y7W D-Y5, D-Y7 D-Y6, D-Y7V D-Y7WV D-Y7BA Bore size (mm) A C 16.5 (15) 23.5 (22) 34 (32.5) 46 (44.5) 46 (44.5) 56 (54.5) D 0.5 (1) 3.5 (2) 0.5 (1) 3 (1.5) 5 (3.5) 5 (3.5) C 18 25 35.5 48 48 58 D 2 5 2 4.5 6.5 6.5 C 10.5 17.5 28 40 40 50 D
SMC 50 35 5 SMC 6 28 (R) P P K U K C S U O C H L S O H L 38 AV AU Panel cut Panel thickness: Max. 4 Panel cut Panel thickness: Max. 3 34 AF 40 15.4 x 5.4 AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IR 8 x 6.5 79 13 45.5 VEX Atmosphere 106 G SET SET Pad side
Flow Characteristics/Weight Flow characteristics C [dm 3/(s bar)] b Cv C [dm 3/(s bar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Weight (g) Pilot port size Type of actuation Port size SYJA512-M5 SYJA522-M5 0.12 0.18 0.39 0.45 0.47 0.66 0.14 0.18 0.45 0.45 N.C. 0.53 0.66 M5 x 0.8 Body ported 45 N.O. M5 x 0.8 SYJA514-01 0.32 0.46 1.1 0.32 0.41 1.2 75 (Without subplate 45) Rc 1/8 N.C.
D D C H B Material: Carbon steel Material: Carbon steel B H Part no. d H B C D Applicable bore size (mm) Part no. d H B C D Applicable bore size (mm) SO-02 SO-03 SO-04 SO-05 NT-02 NT-03 NT-04 AC-NI-50 8 8 9 11 20 25 32 40 M22 x 1.5 M24 x 1.5 M30 x 1.5 M33 x 2.0 30 36.9 43.9 47.3 26 32 38 41 5 6 8 10 12.5 16.5 21.0 23 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 15.0 19.6 25.4 27.7
Traveling parallelism Surface C to surface A Radial clearance D M Surface D to surface B B W Radial clearance A Port C Fixed body MXH MXPJ6 MXP10 MXP12 MXP16 MXP6 MXP8 Model M MXU Radial clearance (m) 0 to 2 0 to 2 0 to 3 0 to 3 0 to 5 0 to 7 The amount of deflection on a dial gauge when the guide block travels a full stroke with the body secured on a reference base surface.
C side parallelism to A side D M D side parallelism to B side B W A Port C MX M MTS B Distance from 0 of gauge dial when guide block is moved to full stroke after body is fixed on a base.
A-A A B B A Auto switch mounting bracket A-A B-B Dust seal band type Seal band holder roller specification C No.
o 4 c > 0 3 I J o o $ 0 2 o 6 a 0 1 f o 5 0 0 0 50 75 100 Input signal %F S Pressure chafacteristicS Set pressure: 0 2tvPa Flow rate characteristics supp v pressure: 0 TMPa Relief flow characteristics suppty pressure: 0.7MPa 1 0 @ I aQ 0 5 o b 0 0 E = = o 0 5 1 0 2000 3000 4000 Flow rate 4min (ANB) lTU2000/3000 tlectro-Pneuma flegula Series |TV205I Hysteresis Linearity Repeatability a u o
D-F5NTL 1 10 D-F5W D-J59W D-F5BAL D-F5F D-F5LF 2 (On different faces or same face) 15 130 125 120 90 70 25 75 10 1 1.12-14
9e c:o c+o coo c+z cse l-cos 'lncludes Rod Packing. Piston Packing, and Tube Gasket (2) Comoact Guide Cytinder: Series MGQ 0120zs,/MGQM'MGQL A Perspective drawing 4-NN Thrcugh NOTE !
0 Unit o Output N NPN open collector 1 output P PNP open collector 1 output A NPN open collector 2 outputs B PNP open collector 2 outputs C NPN open collector 1 output + Analog voltage output D NPN open collector 1 output + Analog current output E PNP open collector 1 output + Analog voltage output F PNP open collector 1 output + Analog current output Nil With unit switching function M SI
C, prevent water droplets from entering the inlet port. (No freezing of the fluid) * Note 2. ANR indicates the flow rate converted to the value at 20 deg. C, under the atmospheric pressure and the state of relative humidity 65%. * Note 3.
SETUP I PORTOPORTLOOP SEC mm2/s LABEL PRO Main modes ALM mm/s L C Directs a program operation. RUN Operation mode ACTUATOR & CONSTRUCTION SYSTEM CONTROLLER POWER ALARM STOP Executes a JOG operation.
C Drain cock Drain guide (A) (B) Rc , NPT, G Mounting bracket Port size Model C B A Drain piping F G H J K L B' D E 6 6 1/4 female thread M3 x 0.5 1 4 2.3 15 12 20 50 73 AMC220 40 56 88 100 22 Depth 8 Body size A B C M3 x 0.5 71 88 101 101 121 55 63 83 96 96 116 1 4 3 8 , 56 75 102 118 135 153 AMC320 75 120.5 140.5 2.3 15 20 30 50 123.5 24 55 2 3 5 6 8 9 Depth 8 M4 x 0.7 1 2 3 4 AMC520
1 4 2.3 15 12 20 50 73 AMC220 40 56 88 100 22 Depth 8 Body size A B C M3 x 0.5 71 88 101 101 121 55 63 83 96 96 116 1 4 3 8 , 56 75 102 118 135 153 AMC320 75 120.5 140.5 2.3 15 20 30 50 123.5 24 55 2 3 5 6 8 9 Depth 8 M4 x 0.7 1 2 3 4 AMC520 102 173.5 193.5 3.2 Depth 8 20 20 30 70 176.5 , 40 70 On the type for the AMC220, an R 1/4 fitting can be attached by removing the drain cock.