.: 04 (ø4), Actuator Type: 01 (Roller Lever), Suffix: S (Hard Steel Roller), Indicator: None, Bracket: B (w/Bracket Included)
.: 04 (ø4), Actuator Type: 01 (Roller Lever), Suffix: S (Hard Steel Roller)
.: 04 (ø4), Actuator Type: 01 (Roller Lever)
.: 04 (ø4), Actuator Type: 01 (Roller Lever), Suffix: S (Hard Steel Roller), Indicator: None, Bracket: B (w/Bracket Included)
.: 04 (ø4), Actuator Type: 01 (Roller Lever)
.: 04 (ø4), Actuator Type: 01 (Roller Lever)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, INLINE TYPE, AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), .50080 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size
NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, NZX MANIFOLD, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, .65120 lb
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL W/FITTING *LQA, AIRLINE EQUIPMENT, AS***F 1/2INCHSTANDARD (NPT), .21958 lb
Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 3-STA, VACUUM EJECTOR, 205 lb
mode lower side set value 12 Wind mode upper side set value 13 Wind mode hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode display -87No.PF-OMZ0002-A [Line name communication data] Value (16 hex number) 00 01
02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -84No.PF-OMY0002 Troubleshooting If an operation failure
02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -84No.PF-OMX0002-B Troubleshooting If an operation failure of the product occurs, please confirm the cause of the troubles
ERR 00: CPU Hung up ERR 01: CPU Check Failure ERR 03: Back-up Data Error ERR 04: EEPROM Writing Error ERR 05: EEPROM Input Over Times Error ERR 11: DC Power Voltage Failure ERR 12: Internal Sensor Value is High ERR 13: Internal Sensor Value is Low ERR 14: Thermostat Alarm ERR 15: Output Failure Alarm (Abnormal output) ERR 17: Cutoff/Short of Internal Sensor ERR 18: Cutoff/Short of External
BA-02 BA-32 BA-04 BA-05 (A set of band (A set of band (A set of band (A set of band (A set of band and screw) and screw) and screw) and screw) and screw) Note 1) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform, methylamines, hydrochloric acid or sulfuric acid is splashed over, so it cannot be used.
Bore size (mm) Mounting bracket Bore size (mm) Auto switch model 20 25 32 40 20 25 32 40 Axial foot D-C7, C8 CNG-L020 CNG-L025 CNG-L032 CNG-L040 BMA2-020 BMA2-025 BMA2-032 BMA2-040 D-H7 Flange CNG-F020 CNG-F025 CNG-F032 CNG-F040 D-B5, B6 Trunnion pin CG-T020 CG-T025 CG-T032 CG-T040 BA-01 BA-02 BA-32 BA-04 Clevis D-G5NT CG-D020 CG-D025 CG-D032 CG-D040 Front trunnion bracket CNG-020-24 CNG
02 03 04 06 10 Type 1 8 ASS100/110 ASS300/310 ASS300/310 ASS500 ASS500/600 ASS600 ASR PAT.PEND 1 4 00 10 Meter-out control type Meter-in control type Meter-in type is available only for ASS110 and ASS310. 8 3 ASF 1 2 3 4 1 JIS Symbol Thread type Nil N F Rc NPT G Meter-out control Meter-in control Caution Be sure to read before handling.
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
BM51 BM52 BM53 BM54 BM55 BM56 BM57 How to Order AME 250 03 R B Option R INOUT reversal Body size HAl Accessories (Options) 150 250 350 450 550 650 850 1/8 1/4 3/8 1/2 3/4 None B AT With bracket IDl Port size 1/8B 01 02 03 04 06 10 14 20 2B 1 Thread 1/4B AMG 11/2 3/8B Rc(PT) F G(PF) N NPT 1/2B AFF 3/4B 1B AMl 11/2B Symbol Related poroducts AME Note) Refer to p.4.7-7 for "How to Order" case
model Bracket assembly AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Symbol BM51 BM52 BM53 BM54 BM55 BM56 BM57 spring washer With cap bolt, AMF Refer to ''Precautions" on p.4.6-33. 4.6-27 Odor Removal Filter Series AMF AMF150 to AMF850 How to Order AMF 250 03 R B Option R IN, OUT reversal Body size Accessories (Optional) 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850 11 2 1 4 3 8 04