Slider type / LEJB series . 19 3.1 Specification. 19 3.2 How to order . 20 3.3 Construction. 21 4. Product Outline . 22 4.1 System construction . 22 4.2 Function / Control mode . 26 5. Wiring and cables / Common precautions . 27 6.

Contact the system supplier for request of inspection and repair. 21 Controller Error FLT Stop An error was detected in the control system. An error was detected in data stored in the controller of this system. 22 Memory Data Error FLT Stop Reset your specified value. Check that a signal is being issued from your system.

L Manifold individual supply specification Note 20, 21, 22) Adjust the supply pressure individually for manifold in order to adjust the vacuum pressure reached by each ejector. When selecting D (with common release pressure supply (PD) port) for manifold option, supplying a pressure which is different from for common PV to common PD is requested.

. ~ White particles can emerge from the surface of the seal during storage, but they do not affect its performance. 21 3-4. Troubleshooting Trouble Major causes Countermeasures Operation has lost smoothness. 1. Lubrication failure Apply the specified grease after cleaning of parts (Grease pack: GR-S-010(10g) GR-S-020(20g)) 2.

N.O. spring Stainless steel wire 5 Finger Stainless steel Heat treatment for spring 6 Roller stopper Stainless steel 18 N.C. spring Stainless steel wire 7 Lever shaft Stainless steel Nitriding for spring 8 Holder Brass Electroless nicked 19 N.C. holder Brass Electroless nickel plated plating 9 Holder lock Stainless steel 20 N.C. spacer Stainless steel 10 Cap Aluminum alloy Clear anodized 21

Specifications 5 Model 7 Note2) FGGLD Note 1) FGGLC Note 1) FGGLB Note 1) FGGSD Note 1) FGGSC Note 1) FGGSB Note 1) Number of elements 14 65 x L250 7 Note2) 21 65 x L250 7 Note2) 28 65 x L250 Stainless steel 304 Stainless steel 304 28 65 x L250 7 Note2) 14 65 x L250 7 Note2) 21 65 x L250 7 Note2) 65 x L500 65 x L750 65 x L1000 65 x L500 65 x L750 65 x L1000 Element size Cover Case O-ring

21 33 33 10.5 17 17 37 37 The value of W in the table means the amount of auto switch protrusion from the body end surface.

1 21 1 Finger opening port M5 x 0.8 +0.1 0 2-5.5 Close: 0 E-E Open: 241 Use the attached hexagon socket head screws for mounting holes. 8-M3 x 0.5 thread depth 4 4-M4 x 0.7 thread depth 5 Mounting thread 44 Attachment mounting thread Auto Switch Mounting Groove Dimensions M3 x 0.5 5 1.7 15 33 4 20 Accessory option: Hexagon socket head screw (special screws) 3.3 3 2-2.5H9 +0.025 0 depth

DM3 x 0.5 (Finger closing port) 20M3 x 0.5 (Finger opening port) 4-M2 x 0.4 (Thread for mounting attachment) 0 -0.05 2.6 4 2.5 5 4.3 12.1 For single action, the port on one side is a breathing hole. 12-2-21 21 Series MHZA2-6 Finger Option Side Tapped Mounting [1] 4-M2 x 0.4 Thread for mounting attachment 2 2 5 2.5 Specifications and dimensions other than the above are the same as the basic

12.0 Nm 11.4 to 22.4 Nm 25.0 to 44.9 Nm M4 x 0.7 M6 x 1.0 M8 x 1.25 M10 x 1.5 D14.1 -X 391 MK Series Construction New MK12, 16 With arm (N) New MK20 to 32 Rod flange (F) #1 #2 MK32-Z New MK40 to 63 Head flange (G) #1 #2 Component Parts Component Parts Material Note Description Aluminum alloy Aluminum alloy Aluminum alloy Aluminum alloy Stainless steel Carbon steel No. 1 2 3 4 No. 18 19 20 21

CE1R00C CE1RC 21 Counter Series CEU Operating Condition of each Output Mode One-shot output With an allowed value Without an allowed value When the counter value passes the sum of the preset value + the allowed value, output is turned ON for 100ms. When the counter value passes the preset value, output is turned ON for 100ms.

OUT 201 IN CQ2 10 20 78 141 204 15 6 OUT 314 MU IN 12 25 126 224 323 21 11 OUT 491 Snap Ring Installation/Removal Caution IN 84.8 6 12 14 31 48 10 3 OUT IN 151 8 16 24 54 85 19 4 OUT q For installation and removal, use an appropriate pair of pliers (Tool for installing a C snap ring). w Exercise caution even when using an appropriate pair of pliers because of the possibility ofthe snap

M M AKH03-00 AKH07-00 AKH09-00 AKH11-00 AKH13-00 5/32 1/4 5/16 3/8 1/2 3 6 10 17 24 2.8 6.5 14 24 34 9.3 12 15.2 18.5 21.7 33.5 39 53.3 63.6 70.2 12.7 13.6 18.5 21 22 L Metric Size Male connector type: AKH H (Hexagon width across flats) Connection thread R Applicable tubing O.D.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Mounting thread 4 58 4 40 68 M5 x 0.8 2-M4 x 0.7 thread depth 5 20 54 Finger closing port Mounting thread E 7.7 14.8 15 19 25 E 0 -0.1 20 2-3.4 through (Mounting hole) 21 1 21 1 Finger opening port M5 x 0.8 +0.1 0 2-5.5 Close: 0 E-E Open: 241 Use the

DM3 x 0.5 (Finger closing port) 20M3 x 0.5 (Finger opening port) 4-M2 x 0.4 (Thread for mounting attachment) 0 -0.05 2.6 4 2.5 5 4.3 12.1 For single action, the port on one side is a breathing hole. 12-2-21 21 Series MHZA2-6 Finger Option Side Tapped Mounting [1] 4-M2 x 0.4 Thread for mounting attachment 2 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

Model D L M AKH04-00 AKH06-00 AKH08-00 AKH10-00 AKH12-00 3 5 10 17 25 4 6 8 10 12 2.8 6.5 14 24 34 9.3 11.6 15.2 18.5 21.7 33.5 37.1 53.3 63.6 70.2 12.7 13.5 18.5 21 22 2-Applicable tubing D Inch Size Weight g Effective area (mm) Applicable tube O.D.

Accessories 21 to 24 (Options) 25 Technical Data Pressure dew pointCondensed water calculation chart, Pressure dew point temperatureAtmospheric pressure dew point temperature conversion cart Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity.

28 29 25 27 34 18 X 21 14 1 R P 3.5 40 4 26 40.5 26 34 4 48.7 10 2-M4 x 0.7 2-4.5 54.2 55.5 (3.6) 54.2 (Mounting screw) (For mounting) 8 1 (P, A, R port) 0.8 54.5 P R 1.8 (Breathing hole) 1.8 (Breathing hole) 20 16 14.5 With filter (80 mesh) 12 With filter (80 mesh) 23 15 , 8 1 4 1 48 (P, A, R port) 5-4-8

1 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 Compact yet provides a large flow capacity Various manifold piping directions V100 Output port: Manifold set-up allowing 360 rotation of 2 (A) entry direction (in 90 increments) Body width 18 mm SY Type 20 and 21 SYJ Available in vacuum applications (101.2 kPa) VK VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco