SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20B-L-M-M5-SA4"

(mm) D2 L A M D1 Applicable tubing KXH04-M5 KXH04-M6 KXH04-01S KXH06-M5 KXH06-M6 KXH06-01S KXH06-02S KXH08-01S KXH08-02S KXH08-03S KXH10-02S KXH10-03S KXH10-04S KXH12-03S KXH12-04S M5 x 0.8 M6 x 1 38.5 11 13 39 35 8 10.4 16 2.5 4.0 4.0 4 40 39.5 40 42 45 46 49 50 58 59 62 60 63 16 36 1 8 M5 x 0.8 M6 x 1 12 2.5 3 4.0 4.0 5.6 5.6 15 8 36 6 12.8 15 17 1 8 1 4 1 8 38 39 42 43 44 20 26 28 34 42

ISA3-F ISA3-G ISA3-H Piping length: 1 m Piping length: 1 m Piping length: 1 m Piping length: 3 m Piping length: 3 m Piping length: 3 m Piping length: 5 m Piping length: 5 m Piping length: 5 m -17No.PS-OMR0002-K 2 About this product Response time Response time is the elapsed time between the pressure supply and the turning ON of the switch output.

ISA3-F ISA3-G ISA3-H Piping length: 1 m Piping length: 1 m Piping length: 1 m Piping length: 3 m Piping length: 3 m Piping length: 3 m Piping length: 5 m Piping length: 5 m Piping length: 5 m -18No.PS-OMT0002-E 2 About this product Response time Response time is the elapsed time between the pressure supply and the turning ON of the switch output.

Required screws are as follows: 2 x M5 (End plate: torque = 1.5 Nm) 2 x M5 (SI Unit: torque = 1.5 Nm) 4 x M (Valve manifold: refer to valve manifold catalogue) Fig. 3-1 Required screws Caution All manifolds are mounted using 8 screws (except VQC4000 which uses 7 screws). -13No.EX##-OMU0020-A 3.1.1. Valve manifold connection Connect the valve manifold with the 2 screws on the SI Unit.

Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z In addition to the models in the above table, there are some other auto switches that are applicable.

H H + Stroke B C ZZ + 2 Stroke CJ2 CM2 e e e d d CG1 f 10.2 10.2 l l + Stroke f l f 10.2 h + l h + l + Stroke S + Stroke h + l MB ZZ + l + 2 Stroke ZZ + 2l + 2 Stroke (mm) MB1 Stroke range (mm) A Bore size (mm) 40 50 63 80 100 AL B B1 C D E F G H1 J K KA M MM N Without rod boot With rod boot CA2 Up to 500 20 to 500 30 27 60 22 44 16 32 10 15 8 M8 x 1.25 6 14 11 M14 x 1.5 27 Up to 600 20

Dimensions/12 to 25 Standard (Through-hole/Both ends tapped)/CQSYB, CDQSYB 12 2-M5 x 0.8 Auto switch Lead wire min. bending radius 10 H thread effective depth C 2 x 4-OB counter bore depth RB 2 x 4-OA effective depth RA Note 1) Q F 16 I 4-N through D M E T Plain washer K B + Stroke L M A + Stroke E 20, 25 Rod end male thread H1 Rod end nut Note 2) C1 X L1 Rod end male thread Bore size (mm

Cable length(L)[m] A1 1 2 5 6 (17.7) (10.2) (14) (18) 1 3 5 8 A B C 1.5 3 5 8 A6 B1 B3 A1 A3 B6 (13.5) 1 2 15 16 (5.7) Connector B Connector D (30.7) L (11) (14.7) (10) 8 A B C 10 LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m (Produced upon receipt of order) 15 Actuator side Controller side 20 (5.5) (6.3) (5.7) (14.2) Connector C (Terminal no.)

Wiring specifications Grommet type (Lead wire: 0.6 m) Nil Grommet type (Lead wire: 3 m) L Connector type (Lead wire: 0.6 m) C Connector type (Lead wire: 3 m) CL Without connector CN Analog output is only available in a grommet type. Please refer to page 16-4-5 for figure.

Wiring specifications Grommet type (Lead wire: 0.6 m) Nil Grommet type (Lead wire: 3 m) L Connector type (Lead wire: 0.6 m) C Connector type (Lead wire: 3 m) CL Without connector CN Analog output is only available in a grommet type.

RSH80 RSH80 RSH80 200 200 RSH63 RSH63 RSH63 RSH50 RSH50 RSH50 0.9 Operating pressure : P (MPa) 100 100 0.8 0.7 0 0 10 20 30 40 10 20 30 40 Load speed : u (m/min) m=0.1 0.6 Load speed : u (m/min) m=0 0.5 0.4 Graphe Graphr Bore size 20, 32/ m =0 Bore size 20, 32/ m =0.1 0.3 0.2 0.1 80 80 1000 2000 3000 4000 5000 0 32 Lateral load: W (N) 70 70 60 60 50 50 Weight : W (kg) Weight : W (kg) 32 40

DOZ is not available. 2 9 Other Option Electrical entry 3 position closed center G: Grommet Lead wire length: 300 mm L: L plug connector With lead wire LN: L plug connector Without lead wire LO: L plug connector Without connector D: DIN terminal 3 3 position exhaust center 4 M: M plug connector With lead wire MN: M plug connector Without lead wire MO: M plug connector Without connector

L4 L5 M1 d AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3 12.7 AS121F-U10/32-03T AS121F-M5-04T 28.4 4 9.3 M5 x 0.8 8 9.6 4.5 31 0.7 31 0.7 28.4 10-32UNF 8 9.6 4.5 AS121F-M5-06T AS121F-U10/32-05T 3/16" 11.4 21.3 26.1 16.5 11.6 6 18.1 11.7 13.5 22.9 18.3 23.1 11.7 AS121F-U10/32-07T AS221F-01-23ST 1/4" 12 13.5 3.2 8.4 12.7 AS221F-01-04ST AS221F-N01

T-brackets T-nuts Model LC1-1-L5 (Weight: 16.0g) Model LC1-1-L3 (Weight: 15.5g) M (Weight: 10.0g) M5 M3 17.5 17.5 17.5 7.5 18 12 11 Model M 20 7.5 7.5 21 LC1-1-N3 M3 x 0.5 29 30 LC1-1-N5 M5 x 0.8 Controller Connectors These are connectors 'all halfpitch type' used for CN1 (control input/output) and CN2 (general purpose input/output).

Cable size Crimped terminal on the rated current thermo-chiller side HRS100-Al-20-l HRS100-Wl-20-l 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 4 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 30 A M5 HRS150-Al-20-l HRS150-Wl-20-l 40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable R8-5) R8-5 A HRS100-Al-40-l HRS100-Wl-40-l 3-phase 380 to

Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube 1 m, 3 m, 5 m Test conditions G, H type: 6 x 4 tube 1 m, 3 m, 5 m Supply pressure: 200 kPa ISA3-F ISA3-G Piping length: 1 m, 3 m, 5 m Piping length: 1 m, 3 m, 5 m : In the default condition, the value can be displayed as 0. : In the default condition, when the distance is below 9, 0 will be displayed.

The spacing (L) of the support must be no more than the values shown in the below graph. MY2 H/HT MY3A MY3B m (800) MY3M 50 L (600) 40 m L 30 MY1H40 (550) Mass m (kg) m MY1H32 20 L L MY1H25 10 Caution 1. If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Therefore, be sure to level the cylinder tube when mounting it.

Pressure (MPa) Lifting height (m) Pressure (MPa) Circulating fluid flow (l/min) Circulating fluid flow (l/min) HRZ001-H1/002-H1 0.5 40 [Outlet port: 60 Hz] 0.4 30 0.3 [Outlet port: 50 Hz] 20 0.2 10 0.1 [Return port] 0 0 0 10 20 30 40 Lifting height (m) Pressure (MPa) Circulating fluid flow (l/min) When the circulating fluid flow is below 6 l /min, the in-built operation stop alarm will

(Tolerance 30%) Dimensions Bore size (mm) Z Auto switch part number H H' HW C T T' D-G39C-4, D-K39C-4 D-G39C-5, D-K39C-5 D-G39C-6, D-K39C-6 D-G39C-8, D-K39C-8 D-G39C-10, D-K39C-10 40 50 63 80 100 57 58 60.5 64 67 69 77 91 107 121 44 52 64 78 92 49.5 50.5 52 53.5 56.5 7.5 8.5 10.5 12.5 15.5 6.5 6.5 7.5 9.5 9.5 M5 X 0.8 X 16 M5 X 0.8 X 20 M5 X 0.8 X 25 5.3-38 Solid State Switch/Direct Mounting

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)