SMC Corporation of America
Elite Part Number Search
Search Results "Y44-04-1-D"

Nil N F Rc NPT G OUT 1 IN Port size Symbol 01 02 03 04 06 Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Voltage 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Consult SMC regarding other voltages.

(mm) Fitting size D 3.2 4 Weight g B C E F A Model M-32R-2 M-04R-2 36 36.5 31 .5 32 0.9 0.7 0.8 2 x 1 .2 20.5 4 Parts list Note Electroless nickel plated Electroless nickel plated Material Brass Brass PP No. 1 2 3 Description Sleeve Studded body Stem Applicable fitting size D Applicable tubing 3 2 1 C F D E B A 3

HRX-OM-M005 Table of Contents Table of Contents Chapter 1 Safety Instructions . 1-1 1.1 Before Using this Product . 1-1 1.2 Hazards. 1-2 1.2.1 Hazard Levels . 1-2 1.2.2 Definitions of Serious injury and Minor injury . 1-2 1.2.3 Symbols . 1-3 1.3 Hazard Warning Label . 1-4 1.3.1 Type of hazard warning label . 1-4 1.3.2 Location of hazard warning label . 1-5 1.4 Location of Model Label . 1-

D L2 L3 L4 L5 L6 L7 L8 P d h T L1 Model Model ASS10 ASS100 ASS110 2 10 5 20 9 5 20 52 14 4 17 50 XT14-82-3-1 1 8 ASS30 ASS300 ASS310 3.2 12 6 30 12 6 26 73 23 5 16.5 63 XT14-105-5-1 1 4 3 8 , ASS500 ASS500 2.3 14 7 35 13 6 38 99 27 6 30.5 90 XT14-89-2-1 1 2 3 4 , ASS600 ASS600 3.2 14 7 65 14 6 46 116 31 6 26 112 XT14-85-2-1 3 4 1 , AS Meter-in Control Type Meter-out Control Type ASP Mounting

JM-025 NSNJ-015 JM-08 NSN-03 NSN-04 0.26 0.30 0.30 0.39 0.39 0.51 0.51 1.00 1.13 1.50 2.00 2.00 2.13 2.50 2.50 3.00 0.47 0.59 0.71 0.91 1.08 1.36 2.44 2.50 3.25 4.17 4.38 4.88 5.88 7.00 7.50 1.18 1.26 5/16-24UNF 3/8-24UNF 3.07 3.24 3.99 5.19 5.38 6.14 7.14 7.16 7.66 C H B d 1/4-28UNF 3/8-24UNF 5/8-18UNF 1-12UNF 1-1/4-12UNF H 0.16 0.12 0.38 0.31 0.43 B 0.44 0.55 0.94 1.22 1.61 C 0.51 0.64

M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS

No.1 No.2 No.3 No.4 No.5 No.6 1 2 4 8 16 32 0 0 0 0 0 0 0 1 1 0 0 0 0 0 MAC ID 2 0 1 0 0 0 0 62 0 1 1 1 1 1 63 1 1 1 1 1 1 Communication speed setting (switches No. 7 to 8) Set the DeviceNetTM communication speed with a binary code of 125 kbps or 250 kbps or 500 kbps.

-B 3.3 3.3.1 1 2 3ISO8573-1: 2010 (JIS B 8392-1: 2012)2:6:3 ISO8573-1: 2010 (JIS B8392-1: 2012) AFM AFF AF AR 2 : 6 : 3 3 dm 1 m 3) 0.1 d 0.5 0.5 d 1.0 1.0 d 5.0 oC) ( (mg/m 1 20,000 400 10 1 -70 1 0.01 2 400,000 6,000 100 2 -40 2 0.1 3 90,000 1,000 3 -20 3 1 4 10,000 4 +3 4 5 5 100,000 5 +7 6 +10 3.3.2 1 13 - No.ZQ-OM01401-B 3.4 3.4.1 M546 0.3 to 0.5[MPa

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)

Stations: 04 (4 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: Rc, Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None)

Stations: 04 (4 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None)

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: Â

PF3A702H AC40#-D Y400-D Y400T-D E400-#04-D : For more information about the options, refer to our website (URL https://www.smcworld.com). 4 Snap shot function The current flow rate value can be stored to the switch output ON/OFF set point.

Example) AWM30-03BE-1N AWD 30 03 BE q w e r t Body size Description Symbol 30 40 20 Nil N Note 1) F Note 2) Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 4) H Mounting Without mounting option With bracket With set nut a + Without auto drain Float type auto drain (N.C.)

Example) AWM30-03BE-1N AWD 30 03 BE q w e r t Body size Description Symbol 30 40 20 Nil N Note 1) F Note 2) Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 4) H Mounting Without mounting option With bracket With set nut a + Without auto drain Float type auto drain (N.C.)

PF3A802H AC40#-D Y400-D Y400T-D E400-#04-D 4 : For more information about the options, refer to our website (URL https://www.smcworld.com). Do not apply torsion or bending moment other than the weight of the product itself. External piping needs to be supported separately as it may cause damage.