Search Results "VV5K3-20-10"

Auto Switch Specifications Grommet Electrical entry: In-line PLC: Abbreviation of Programmable Logic Controller D-A7H (With indicator light) D-A72H D-A73H D-A76H Auto switch model Applicable load Relay, PLC Relay, PLC IC circuit Load voltage 200 VAC 24 VDC 4 to 8 VDC 100 VAC Max. load voltage/Load current range(3) 5 to 10 mA 5 to 40 mA 20 mA 5 to 20 mA Contact protection circuit 2.4 V or

Auto Switch Specifications Grommet Electrical entry: In-line PLC: Abbreviation of Programmable Logic Controller D-A7H (With indicator light) D-A72H D-A73H D-A76H Auto switch model Applicable load Relay, PLC Relay, PLC IC circuit Load voltage 200 VAC 24 VDC 4 to 8 VDC 100 VAC Max. load voltage/Load current range(3) 5 to 10 mA 5 to 40 mA 20 mA 5 to 20 mA Contact protection circuit 2.4 V or

V, 1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA 12 bit resolution Input signal range 10 to 10 V, 5 to 5 V 20 to 20 mA 16 bit resolution EX600-AXA 15 V 22 mA Note 2) Max. rated input signal 50 100 k Input impedance 0.05% F .S.

of product Measurable Range for Ethylene Glycol Aqueous Solution (Reference Value) 3-Color Display Digital Flow Switch for PVC Piping 100 Aqueous solution concentration [%] (Weight) 90 80 70 60 50 40 30 20 10 Measurable within this range PF3W 0 0 10 20 30 40 50 60 70 80 90 Aqueous solution temperature [oC] Wetted Parts Construction o !

40 40 40 40 20 Suction flow rate 10 20 20 20 20 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 5 10 15 20 25 0 0 0 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 2 4 6 8 10 12 14 Supply pressure [MPa] Suction flow rate [L/min (ANR)] Supply pressure [MPa] Suction flow rate [L/min (ANR)] ZH10SA ZH10LA Exhaust Characteristics Flow Rate Characteristics Exhaust Characteristics Flow Rate Characteristics 100 100 100

0.5 50 Pump head[m] Availavel area 0.4 40 Outlet60Hz 0.3 30 Outlet50Hz 0.2 20 0.1 10 Return port Availavel area 0.0 0 10 20 30 40 Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS060--20-(BJM)) 9.7 Required facility water flow (For water-cooled type) 30 Facility water flow rate[L/min] 25 20 15 10 5 0 0 10 20 30 40 50 Facility water inlet temperature[] *The amount of the facility water

A1 L1 R1 U1 NDH10 E1 MM NX Applicable bore size (mm) I-020B I-032B I-04A IA-04 A B C D E F M R Size Tolerance Note +0.027 0 +0.027 0 +0.027 0 +0.027 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.1 0.2 0.1 0.2 0.1 0.3 0.1 0.3 AD-FI-20 AD-FI-25 AD-FI-32 AD-FI-40 9 9 16 16 16 18 22 22 36 38 55 55 9 9 12 12 10 10 15.5 15.5 20 25 32 40 20 20 24 24 14 14 20 20 30 10 16 22 60 20 25 32 40 46 28 M8 x 1.25

20 00N 20 stations NPT SS5X3-20-05 (5 stations) NPTF 00T Stations3 2 1 Connector assembly for L and M types Refer to page 1-6-8.

For example, changing from F Kit (D-sub connector) to S Kit (serial transmission) is achieved by simply changing the kit piece. 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 COM Station 1 Double wiring Station 2 Single wiring Station 3 Double wiring Station 4 Single wiring (Refer to the connector wiring diagram) Printed circuit board patterns between connectors are shifted at every station

. 9-1 9.1.2 HRLE090-A-20. 9-2 9.1.3 HRLE050-W-20. 9-3 9.1.4 HRLE090-W-20. 9-4 9.1.5 HRLE090-A-40. 9-5 9.1.6 HRLE090-W-40. 9-6 9.2 REFRIGERANT AND GWP VALUE . 9-7 9.3 DIMENSIONS . 9-8 9.3.1 HRLE050-A-20. 9-8 9.3.2 HRLE050-W-20. 9-9 9.3.3 HRLE090-A-20/40. 9-10 9.3.4 HRLE090-W-20/40. 9-11 9.4 FLOW DIAGRAM . 9-12 9.4.1 HRLE050-A-20-*,HRLE090-A-20/40. 9-12 9.4.2 HRLE050-W-20-*,HRLE090-W-20/40.

20 0.7 MPa 0.7 MPa 10 10 0 20 40 60 80 100 0 0 0 50 100 150 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC74 6 ZFC75 8 0.1 MPa 0.3 MPa 0.5 MPa 0.1 MPa 0.3 MPa 30 30 Differential pressure [kPa] Differential pressure [kPa] 0.5 MPa 0.7 MPa 20 20 0.7 MPa 10 10 0 50 100 150 250 200 0 0 0 100 200 300 400 500 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC76 10 ZFC77 12 0.1 MPa 0.3

(up to 24 solenoids possible) D side 20 20 20 stations 20 stations Connector entry direction PG: Flat cable connector (20 pins) PH: Flat cable connector (10 pins) 1: Perpendicular connector 2: Lateral connector Note Symbol 02 Note Symbol 02 Stations Stations 2 stations 2 stations Double wiring specification Double wiring specification ... ... ... ... 09 10 04 05 9 stations 4 stations 10 stations

20 30 40 10 20 30 40 0 0 0.6 CE1 Transfer speed [m/min] = 0 Transfer speed [m/min] = 0.1 0.5 0.4 CE2 Graph (3) Graph (4) Bore size 20, 32/ = 0 Bore size 20, 32/ = 0.1 0.3 ML2B 0.2 0.1 C J G5-S 80 80 1000 2000 3000 4000 0 5000 Lateral load F [N] 32 CV 70 70 MVGQ 60 60 CC 50 50 32 RB 40 40 30 30 J 20 20 20 D20 10 10 -X 200 0 10 20 30 40 10 20 30 40 Transfer speed [m/min] = 0 Transfer

L/min) Facility water flow rate: 2.6 gpm (10 L/min) 0 0 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 Circulating fluid temperature (C) Circulating fluid temperature (C) 148 Series HEC-W Peltier-Type Chiller Thermo-con (Water-cooled) The values shown on the performance chart are not guaranteed, but typical.

CAT.ES20-147 A Compact Rotary Actuator Rack-and-Pinion Type/Sizes: 10, 15, 20, 30, 40 Series CRQ2 Compact Rotary Actuator Rack-and-Pinion Type/Sizes: 10, 15, 20, 30, 40 Series CRQ2 Piping can be installed from one end Body can be used as a flange Compact design saves mounting space Uses internal cushioning 10, 15 : Rubber bumper 20, 30, 40: Air cushion 10: 17mm 15: 20mm 20: 29mm 30: 33mm

size Model 11-/22-CXS6 6 11-/22-CXS10 11-/22-CXS15 11-/22-CXS20 11-/22-CXS25 11-/22-CXS32 10 15 20 25 32 10, 20, 30, 40, 50 Vacuum suction type Relief type M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Double acting (Both sides) Non-lube 10-/12-/21-CXS6 6 single rod 10-/12-/21-CXS10 10-/12-/21-CXS15 10-/12-/21-CXS20 10-/12-/21-CXS25 10-/12-/21-CXS32 10, 20, 30, 40, 50 10 15 20 25 32 M5 x 0.8

151 14 20 18 36 10 57.5 7 11.2 6.6 33 158.4 64 79.5 78 5.5 76.5 8 54 62 72 40 185 209 10 199 14 22 18 36 10 64.5 195.2 59 71.5 65.5 215.7 8 14.7 9 71 39 173.4 83.5 79 94 95 6.6 91 9 78 67 76 89 50 202 235 14 221 20 28 22 44 14 76.5 219.2 9 16.2 11 46 177.4 95 9 9 91 80 92 60 203 238 14 224 20 30 22 44 14 89.5 84.5 97 109.5 113 107 108 Dimensions for auto switch model D-F79W. 16 Series CEU

-R . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS018-A-20--R . 9-7 9.4.2 HRS030-A-20--R . 9-7 9.5 Heating capacity . 9-8 9.5.1 HRS018-A-20-R, HRS030-A-20-R . 9-8 9.6 Pump capacity. 9-9 9.6.1 HRS018-A-20-R, HRS030-A-20-R . 9-9 9.6.2 HRS018-A-20-T-R, HRS030-A-20-T-R . 9-9 9.7 Compliance . 9-10 9.8 Sample DoC. . 9-11 9.9 Daily Check Sheet . 9-12 Chapter 10 Product Warranty . 10-1 HRS-R Series HRX-OM-W058

WW WW WA WB D NDh8 MM NN GA GC Piping port 3-M5 x 0.8 GB Piping port M5 x 0.8 C A F NA NB B 0 -0.3 Head cover port location Axial direction (R) S + Stroke H Z + Stroke (mm) M4 x 0.7 D GC B F H MM GB GA C A S NN NDh8 Z WW WA WB 28 28 NA 102.5 101.5 5.5 4.5 20 20 NB Bore size M10 x 1.0 12-0.027 10-0.022 23 23 13.5 0 29.5 29.5 4 5 74.5 73.5 16 10 15 15 18.3 15 20 17 8 8 5 5 6.5 6.5 11 11 13.5