CY3RG25 CY3RG32 CY3RG40 16 Series CY3R Auto Switch Proper Mounting Position for Stroke End Detection Auto Switch Operation Range (Reference dimension) Bore size (mm) Auto switch model 15 20 25 32 40 D-A9 8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.
Ejector mounting position ZZYX3 45T U side D side U D J Mounting position of connector Number of ejectors 1 to 3 stations A, B port size (Valve only) U side D side U D C4 C6 4 One-touch fitting 6 One-touch fitting Mixed M SUP/EXH block assembly mounting position Total number of ejector/valve stations U D side D B U side When creating the mixed specifications, complete the stations table on
Product (15) Plug assembly -24- 11. Disassembly Drawing 11-1. AR20-D/ AR30-D/ AR40-D/ AR50-D/ AR60-D Cross recessed round head screws (4 pcs.) (10) Valve assembly Bonnet Valve spring (Protrusion on IN side) Washer (only for 50 and 60 sizes) Pressure regulating screw assembly (12) Valve guide assembly Pressure regulating spring Cover (11) Diaphragm assembly Cap OUT Body I N -25- 11-2.
Example) XLA-25H0-2M9NJLA-XAN1A 18 XLm Series Dimensions XLA/F (With D-M9mJm) C E E C E Fn D Heat-resistant auto switch H B A Heater G A [mm] Series Valve size A B C D E Fn G H 25 50 121 48 27 12 40 26 44 40 65 171 66 39 11 55 41 67 50 70 185 79 46 11 75 52 72 XLA XLF XLC/G25, 40 (With D-M9mJm) XLC/G50 (With D-M9mJm) C E C E E C E E C E Fn B A Fn D D Heat-resistant auto switch H J K H B A
Weight (g) Model D-A90 6 30 D-A90V 6 30 D-A93 6 11 30 47 D-A93V 6 30 47 D-A96 8 41 D-A96V 8 41 0.5 m (Nil) 1 m (M) 3 m (L) 5 m (Z) Lead wire length Dimensions (mm) D-A90/D-A93/D-A96 D-A90V/D-A93V/D-A96V 2 2.8 4.5 2.7 Slotted set screw M2.5 x 4 L 4 24.5 (22) 22 2 6 Slotted set screw M2.5 x 4 L D-A90 without indicator light Indicator light 2.7 D-A90V without indicator light Indicator
D-M9W D-A9 D-A9V D-H7C D-C73C D-C80C D-G5NTL D-B5 D-B59W D-B64 Auto switch model D-M9V D-M9WV D-H7 D-H7W D-H7BAL D-H7NF D-C7 D-C80 (in) D-M9 D-M9W D-A9 D-H7 D-H7W D-H7C D-H7BAL D-H7NF D-C7 D-C80 D-C73C D-C80C D-G5NTL D-B5 D-B64 D-B59W Auto switch model HS 0.96 1.02 1.12 1.22 1.34 1.59 HS 0.98 1.04 1.14 1.24 1.36 1.61 HS 0.85 0.91 0.96 1.06 1.18 1.44 HS 0.87 0.93 0.98 1.08 1.20 1.46 HS 0.98
5 7 8 7 10 13 17 22 27 14.4 19 24.8 29 38.4 49.2 17 23 29.9 33.5 38 47.5 80 210 JS20-8-125 JS32-10-125 M8 x 1.25 M10 x 1.25 43.9 49.5 1100 2500 6000 11000 JS40-14-150 JS63-18-150 M14 x 1.5 M18 x 1.5 60 74.5 11 13.5 Rod end nut (mm) d: Thread nominal size 30 Description H B C D d JS10 nut M4 x 0.7 3.2 7 8.1 6.8 JS16 nut M5 x 0.8 4 8 9.2 7.8 JS20 nut M8 x 1.25 5 13 15 12.5 D C JS32 nut M10
end nut (mm) d: Thread nominal size 30 Description H B C D d JS10 nut M4 x 0.7 3.2 7 8.1 6.8 JS16 nut M5 x 0.8 4 8 9.2 7.8 JS20 nut M8 x 1.25 5 13 15 12.5 D C JS32 nut M10 x 1.25 6 17 19.6 16.5 JS40 nut M14 x 1.5 8 22 25.4 21 H B JS63 nut M18 x 1.5 11 27 31.2 26 10-19-14
Single round shaft: ClRA1BT Double shaft (round shaft, with four chamfers): ClRA1BJ Double round shaft: ClRA1BK D D D H H H H UU UU M N 0 0.2 G D L 0 0.2 [mm] [mm] [mm] Size D (g6) H Size D (g6) G H M N UU L Size D (g6) H UU 30 8 25 50 15 36 63 17 41 80 20 50 100 25 60 30 8 6 25 10 8 75 7.8 50 15 11 36 20 15 118 14 63 17 13 41 22 17 139 16 80 20 15 50 25 20 167 19 100 25 19 60 30 25 202 24
Terminal no. 16 16 43 43 Length indication label Length indication label 10 11 19 10 9 2 1 2 1 20 SMC SMC 33.4 33.4 030 015 41 41 25 Approx. 10 Approx. 10 17 8 18 8 7 6 14 26 15 9 2 x M2.6 x 0.45 For N, 2 x No. 4-40 UNC For N, 2 x No. 4-40 UNC 2 x M2.6 x 0.45 Socket section Socket section D-sub Connector Cable Assembly D-sub Connector Cable Assembly Cable length L Assembly part no.
D-A9l D-A9lV D-F9N/D-F9B D-F9P/D-F9lW D-F9lV/D-F9lWV Symbol A B W A B W A B W A B HS Double acting: single rod, Single acting: single rod/spring return, spring extend 4.5 (3.5) 5.5 (6.5) 1.5 (2.5) 1.5[4] (2.5[5]) 2[4.5] 1.5[1] 3.5[-1] 1.5 (2.5) 12 19 5.5 4.5 5.5 17 0 0 Bore size (mm) 16 20 25 21 24.5 26.5 4 7.5 9.5 6 10 11 6 2.5 0.5 4 7.5 9.5 6 10 11 19 22.5 24.5 0 3.5 5.5 2 6 7 0 3.5 5.5
Rc 3/8 EXH: Rc 1/4 60 OUT (328) Tank OUT port Rc 1/2 278 180 170 4 x 11 32 32 Drain port Rc 1/4 120 180 312 460 Connected to VBA20A Connected to VBA22A Tank IN port Rc 3/8 Booster regulator IN port Rc 3/8 Booster regulator IN port Rc 3/8 EXH: Rc 3/8 EXH: Rc 3/8 (454) 442 (417) Tank OUT port Rc 1/2 (367) (367) OUT OUT 278 180 180 170 4 x 11 4 x 11 32 32 120 180 180 120 Drain port Rc 1/4 312
Fitting plug KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 Dimensions L (mm) A Applicable fitting size d A L D Part number KQP-01 KQP-03 KQP-07 KQP-09 KQP-11 5 6 8.5 10 11.5 31.5 32 35 39 43 1/8 5/32 1/4 5/16 3/8 16 16 18 20.5 22 D Used to block unused cylinder port. L DIN rail AXT100-DR12.5 (Pitch) 5.25 7.5 Suffix number into from the dimension table below.
Trigger LV (7, 11) 1% Word10: Pushing speed Description Word Bit Signal name Input range Min. unit 10 0-15 Pushing speed (7, 11) 1 mm/s Word 11: Moving force Description Word Bit Signal name Input range Min. unit 11 0-15 Moving force (7, 11) 1% Word12, 13: AREA 1 Description Word Bit Signal name Input range Min. unit 12 0-15 AREA 1 (Lower digits) Basic parameter "Stroke (-)" "Stroke (+)"
Procedures to Trial run . 10 3.1 Checking the contents of the package . 10 3.2 Mounting the controller . 11 3.3 Install the setting software and the driver . 11 3.4 Wiring and connection . 11 3.5 Power supply, Start-up of controller setting software, and Alarm check 11 (1) Supplying power . 11 (2) Start-up of controller setting software . 12 (3) Alarm check . 13 3.6 Parameters and Step data
IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PV D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA DC24V DC12V Relay PLC
Conduit terminal: VP3185-T A B DIN terminal: VP3185-D A B Conduit terminal with indicator light (TL) Light Light position Max. 11 Applicable cable 6 to 12 [ ]: With indicator light (TL) 1500 Made to Order: Series VP3145/3165/3185 Main Valve Double Acting Type: -X80/X81 How to Order 1 D Z A N X 06 5 1 4 VP31 81 CE-compliant Body size CE-compliant Nil 4 6 8 1 2 Q Electrical entry: D/DO only
Carefully fix the switch blocks (11) to the holding blocks (7) using the cross recessed round head screws (12). 5. Mount the auto switches (2) and (3) to the switch blocks (11) using the cross recessed round head screws (14). 6. Move the switch blocks (11) to the setting position and fasten them with the cross recessed round head screws (2). For D-M9 1.
115 44.5 11 6.4 84 3.3 303 264 43 110 282 98 96 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318 279 45 110 292 98 101 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318 280 46 110 297 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.