Actuator operation from host . 40 8.1 CiA 402 drive profile . 40 8.1.1 FSA state . 40 8.1.2 Controlword / Statusword . 41 8.1.3 Control mode . 42 8.2 Parameter setting . 43 8.3 Servo-on and Homing . 44 8.4 Positioning operation (Profile position mode) . 45 9.
Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-29No.EX-OMV0023-A (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [
6.1 . 20 6.2 . 20 6.3 . 21 1 - . 22 7.CN3 . 23 8.CN1IF(CONT) . 24 8.1 . 24 8.2 . 26 9.CN2TB/PC . 27 9.1 . 27 10.LED . 28 10.1 LED . 28 10.2IFLED . 28 11. . 29 11.1 . 29 11.2 . 29 11.3 . 29 11.4 . 31 12. . 32 12.1 . 32 12.2 IF(IN Data) . 38 12.3 (IN Data) . 38 12.4(OUT Data) . 40 13.
Y DC: 0.45 W (With indicator light: 0.5 W) 24 VDC and 12 VDC are applicable to 0.45 W.
Item CH2 measured value: 16-bit signed integer Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 Item CH32 measured value: 16-bit signed integer Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4 measured value: 16-bit signed integer Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Error diagnosis CH4 diagnosis CH3 diagnosis CH2 diagnosis CH1 diagnosis Reservation
/8 Restrictor (36.5) Clean air filter Note) One-touch fitting 12 103 85 13.2 34.8 3 (41) 111 59 71 80.4 41 59 59 Rc 3/8 (NPT 3/8) 521 3.5 (3.5) Note) This port is unavailable.
Example) VHS30-N03-RZ-D Symbol Description Body size 20 30 40 Thread type Nil Rc*1 N NPT F G 01 1/8 02 1/4 Port size 03 3/8 04 1/2 Nil Flow direction: Left to right a Flow direction Semi-standard R Flow direction: Right to left Nil Name plate in imperial units: MPa b Pressure unit Z*2 Name plate in imperial units: psi *3 *3 *3 *1 EXH port thread type: G *2 For thread type: NPT This product
Filter plate 2 Series FN1 Flow Characteristics (Initial Value) Test fluid: Potable water Liquid temperature: 17 to 20C (room temperature) Test method: Per P/A test method (sanitary test stand) Element length 250mm: FN111-10-S Element length 500mm: FN112-10-S .1 .1 .05 .05 FN111-10-S005 (5m) Pressure loss (MPa) Pressure loss (MPa) FN112-10-S005 (5m) FN111-10-S020 (20m) .01 .01 FN112-10-S020
Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included
Valve model Port size L J H G F E D C A B VCW20-12-01A VCB2 1/8, 1/4 13 6 4.5 5 12.8 12.8 30 25 40 34 VCW30-12-02A 1/4, 3/8 19 7 5.5 6 19 19 40 30 52 42 VCB3 VCW30-12-04A 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-02A 1/4, 3/8 19 7 5.5 6 23 23 40 30 52 42 VCW30-12-04A VCB4 1/2 23 7 5.5 6 23 23 44 36 56 48 VCW40-12-06A 3/4 26 7 5.5 6 28.2 28.2 53 44 65 56 Two mounting screws (for mounting
40 30 40 40 20 20 Suction flow rate Suction flow rate 20 20 20 20 10 10 10 0 0 0 0 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 2 4 6 8 14 12 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 5 10 15 20 Suction flow rate [L/min(ANR)] Suction flow rate [L/min(ANR)] Supply pressure [MPa] Supply pressure [MPa] Dimensions 2 x Applicable tubing O.D. 6 10.4 9.7 L1 L2 13.3 12 13.3 2 x Connection thread Rc1/8 13.3 12 L1
Parts and description Fig. 12-1 Allocation of parts on the EX245-DY1 Note: EX245-DY1 is the new part number for the EX245-DY1-X37 75 No.EX##-OMY0004 12.2.
Data writing mode.36 12. Memory map .37 12. 1 Memory assignment.37 12. 2 Controller IF status flagIN Data.43 12. 3 Gateway unit status flagIN Data.43 12. 4 Gateway unit control flagOUT Data.45 13. Precautions for controlling the controller (LEC).46 13. 1. Communication delay between the gateway unit unit and the controller (LEC) 46 13. 2.
) 10 m or less CN3 10 m or less 24 V DC (Note 10) 3 DOCOM (Note 15) Main circuit power supply CN3 (Note 12) (Note 2) (Note 17) Electromagnetic brake interlock 13 MBR (Note 3, 4) Forced stop 2 RA1 20 EM2 (Note 13) 9 INP In-position RA2 FLS DI1 2 15 ALM Malfunction (Note 11) (Note 14) RLS DI2 12 RA3 DOG DI3 19 5 DICOM Encoder A-phase pulse (differential line driver) 6 LA (Note 10) 24 V DC 16
[%F.S.] 2.0 1.5 1.0 0.5 0.0 0 1 2 3 4 5 [s] [S] [MPa] [MPa] [MPa] [MPa] [ [ [ [ ] ] ] ] 2 69 No.LFE*-OMY0008 / / / / A B C 1 V 1.1 V 5 V 4 mA 4.4 mA 20 mA [L/min] LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 70 No.LFE*-OMY0008 2x )M12 () 1.6mm A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67
Wiring . 12 3.1 Power Supply Wiring . 12 3.2 I/O signal connection . 13 3.2.1 Connection example (Sink I/O interfaces) . 13 3.2.2 Source I/O interfaces . 14 3.3 Wiring of PLC and driver . 15 4. Parameter list (Driver side) . 17 5.
XT53440 05 Number of stations 05 06 12 1 station 2 station 8 station 10
Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without
(Page 13) 0x000C (12) 0 R/W Device Access Locks N For more details, refer to "Device access lock parameter."
Example) ARP30K-03BE-1RY Symbol 20 30 40 Body size Description Nil K Without backflow function With backflow function With backflow function + Nil N F Rc NPT G Thread type + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) a Without mounting option With bracket With set nut (For panel mount) Mounting H + Note 1) Nil E G E1 Note 3) Without pressure gauge Square embedded type pressure