x 10l Metallic painted M3 x 28l Port size: 6 Electroless nickel plated Clear anodized -X Hex. socket head cap screw with spring washer Plate 20Replacement Parts Hex. socket head cap screw with spring washer Solenoid valve Bumper Bumper A Refer to How to order below.
After checking the detection position, tighten M3 screws to fix the auto switch so that the bottom of the auto switch contact the cylinder tube. (The tightening torque of the M3 screw must be 0.5 to 0.7Nm.) Tighten the auto switch mounting screw(M4) to fix the auto switch mounting bracket.
Reference data Units: mm IDH6 Jumper cord 7 6 5 4 3 1 PE Remote start/stop Fault-signal (N.O: Close at "Fault") Fault-signal (N.C: Open at "Fault") 1042 31 N 2 L Operation-signal (N.O) Ground Terminal screw: M3 Suitable wire: 1.25mm or more 2 244 Power supply Connector width: 6.5mm or less Detail of wiring 35 184 172 392 (Note) 15 80 223 321 3001 485 The type without built-in filter does
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 2 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tithe screw (4x14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
JXC-OMT0002-C Part A Part B Holding screw M5X14 (2) Grounding Fit the grounding cable with crimped terminal between the M3 screw and shakeproof washer as shown below and tighten the screw. Shakeproof washer Grounding cable (with crimped terminal) M3 screw Caution The cable with crimped terminal and shakeproof washer must be prepared by the user.
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
) M2 M3 M1 M2 1.25 1.68 Slide 12 3 0.53 0.70 Ball bushing 3.34 4.25 Slide 16 7 1.53 2.11 Ball bushing 11.4 17.1 Slide l l 20 12 5.60 7.28 Ball bushing Note) For the purpose of calculating the moment, the length of the arm is the distance that is measured from the guide shaft center ( mark).
Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ZSE ISE ON YES OFF P-1 P-2 GPM gal (US) PSE Real-time flow rate GPM = gal (US)/min P Window comparator mode H: Hysteresis Z I SE3 Note) Fixed SI unit (l/min, l, m3 or m3 x 10) will be set for the type without the unit switching function.
Stroke range (mm) Bore size (mm) W Stroke range 32, 40 21 to 99 50, 63 31 to 99 Part no. : RLQB32-47-B A special tube is manufactured for a 47 mm stroke.
PF2D5--1 (With voltage output type) PF2D540-19 Display unit (PF2D30/31) 186 Sensor unit 78 86 Brown 6 2 Analog output Switch output or Pulse output Main circuit Main circuit 56 8 4 Load + 12 to 24 VDC 15 White 7 3 Black 5 1 Blue Load is an analog input equipment such as a voltmeter.
Bore size (mm) 32, 40 50, 63 Stroke range (mm) 21 to 99 31 to 99 Stroke range Part number: RLQB32-47-B A special tube is manufactured for a 47 mm stroke.
Switch mounting screws (M3 x 0.5 x 10l) Switch spacer 32, 40 50, 63 Manufacture of intermediate strokes BQ-2 Method Spacers installed in standard stroke body. Switch mounting nut Ordering Refer to standard part number and ordering on page 1.
Vertical mounting: 0 (None) The moment load rate must be calculated in accordance with the above formula for all types, M1 to M3. As for Wmax and Mn, refer to the maximum load mass and allowable moment table in the next section. The moment for the inclined mounting must be calculated taking the moment caused by the load into consideration.
Switch mounting screws (M3 x 0.5 x 10l) Switch spacer 32, 40 50, 63 RS H A Manufacture of Intermediate Stroke BQ-2 Method Spacers installed in standard stroke body. Switch mounting nut RZQ Ordering Refer to standard part number and ordering on page 10-10-2.
Stroke (mm) Pulling force Bore size (mm) 40, 50, 63 80, 100 Thread size 3 10 N M3 x 0.5 x 30l or more 3 24.5 N M5 x 0.8 x 40l or more Remove the bolt for normal operation. It can cause lock malfunction or faulty release. Rubber cap 2. Manual release lock type Push the M/O knob and turn it 90 counterclockwise.
Stroke (mm) Pulling force Bore size (mm) 40, 50, 63 80, 100 Thread size 3 10 N M3 x 0.5 x 30l or more 3 24.5 N M5 x 0.8 x 40l or more Remove the bolt for normal operation. It can cause lock malfunction or faulty release. Rubber cap 2. Manual release lock type Push the M/O knob and turn it 90 counterclockwise.
Inch size Metric size Port size 4 04 03 5/32 M5 M5 x 0.8 Thread type 6 06 07 1/4 U10/32 10-32 UNF 8 08 09 5/16 Metric thread (M5) 01 1/8 Nil 10 10 11 3/8 Unified thread (10-32 UNF) 02 1/4 12 12 13 1/2 R 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tubing O.D./Port Size Combinations From male thread to One-touch fitting A Metric size Inch size Applicable tubing O.D.
Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.
Add to Cart SMC AXT100-DR-30 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $11.55 Add to Quote Add To Cart Add to Cart SMC AXT100-DR-31