Dimensions 31 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Dimensions 31 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Unit: g (oz) D-F9N (V) D-F9BV D-F9PV D-F9NV D-F9B D-F9P D-F9N Type 6 (0.21) 7 (0.25) 7 (0.25) 6 (0.21) 7 (0.25) 7 (0.25) Lead wire length 0.5m DC (+) Brown [Red] 31 (1.09) 37 (1.31) 37 (1.31) 31 (1.31) 37 (1.31) 37 (1.31) Lead wire length 3m Main switch circuit Auto Switch Dimensions (mm) OUT Black [White] 1in = 25.4mm D-F9N, D-F9P, D-F9B DC () Blue [Black] D-F9P (V) DC (+) Brown [Red] Main
Mounting screw (M4) Terminal block cover M3 screw Gasket 6mm Electrical entry 2-G3/4 Step 3. How to replace the terminal block cover Securely tighten the screws to the torque shown in the table below, after confirming that the gasket is installed correctly.
Grommet: G DIN terminal: D 4-Rc(PT) 1/8 (ports P, R) Manual override (non-locking) Applicable cord O.D. 4 to 6.5 Max .10 71.5 78.5 71 Light (DZ type only) 2-4.5 (mounting holes) 67.5 59 19 17 2 R P P R 34 2.3 7 20 Pg.7 4-Rc(PT) 1/8 (ports P, R) A A A P = 19 13.5 L2 L1 4 1 7 8 26 47.5 Approx. 300 (lead wire length) n-Rc(PT) 1/8, M5 x 0.8 (port A) 7 20 34 2-4.5 (bracket mounting holes) 4-M3
B C D 44 Mounting J ig to the piston 43 Mounting to workpiece Fem ale thread type Male thread type D o No.LZ-OM00401 B (3/3) (44) 1908-56 38 88 Hungary (36) 1-371 1343 Turkey (90) 212 221 15 12 Finland (358) 9-859 580 Portugal (351) 22 610 89 22 Denmark (45) 70 25 29 00 Poland (48) 22-548 50 85 Greece (30) 1-342 60 76 Switzerland (41) 52-396 31 31 France (33) 1-64 76 10 00 Spain (34) 945-
x 10l Metallic painted M3 x 28l Port size: 6 Electroless nickel plated Clear anodized -X Hex. socket head cap screw with spring washer Plate 20Replacement Parts Hex. socket head cap screw with spring washer Solenoid valve Bumper Bumper A Refer to How to order below.
Note 1) Note 2) Max. vacuum pressure Manual override S L 84 kPa 53 kPa Nil D E Non-locking push type Push-turn locking slotted type Push-turn locking lever type Nozzle diameter 07 10 0.7 mm 1.0 mm 1082 Ejector Valve Unit Series ZYY/ZYX How to Order Ejector Valves for ZYX3000 ZA Lead wire/ Voltage suppressor specifications ZX Plug-in type Serial transmission type LOZ ZR LOZ 10 X3 ZY 5 M Z
Bit offset Item Notes 0 OUT1 output 0: OFF 1: ON 1 OUT2 output 0: OFF 1: ON 8 Measurement diagnostics 0: Within range 1: Out of range (HHH) 14 Fixed output 0: Normal output 1: Fixed output (Setting of output check) 15 Error Diagnosis 0: Error not generated 1: Error generated 16 to 31 Flow measurement value With sign: 16 bit Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item Flow
How to Order With bumper Series RBQC Basic type Series RBQ C 20 07 RBQ RBQC C Replacement part no.
each actuator . 21 6.3.5 Forced stop input selection . 24 6.3.6 Absolute position detection system . 25 6.3.7 Verify of parameters . 26 6.3.8 Parameter initialization . 27 6.4 JOG Mode in the Setup Software .28 6.4.1 JOG Mode . 29 6.5 Changing Output Signal Allocation .30 6.5.1 Initial I/O Signal Allocation . 30 6.5.2 Signal Allocation using Setup Software . 30 6.5.3 Allocation Examples . 31
Example of Selection from Minimum Operating Flow 100 Example) Vacuum saving valve used: ZP2V-A8-05 From Table 1, Q2 can be calculated as 5.0 l/min (ANR). 90 31 {l/min (ANR)} 5 {l/min (ANR)} 80 N = 6 (unit) Vacuum pressure (kPa) 70 Q2 = 5.0 l/min (ANR) 60 Table 1.
How to Order With bumper Series RBQC Basic type Series RBQ C 20 07 RBQ RBQC C Replacement part no.
Model Specifications AN101-01 AN110-01 AN120-M3 AN120-M5 R R M3 M5 1 8 1 8 Port size (1) Noise reduction (dB (A)) Fluid Max. operating pressure (2) 13 18 16 21 Compressed air 1.0 MPa 5 to 150C (3) Ambient and fluid temperature Effective area (mm2) Weight (g) 20 35 1 5 9.5 20 1 3.3 22.5 38 9 17 11 A B 13 6 8 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370
After checking the detection position, tighten M3 screws to fix the auto switch so that the bottom of the auto switch contact the cylinder tube. (The tightening torque of the M3 screw must be 0.5 to 0.7Nm.) Tighten the auto switch mounting screw(M4) to fix the auto switch mounting bracket.
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 2 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tithe screw (4x14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
JXC-OMT0002-C Part A Part B Holding screw M5X14 (2) Grounding Fit the grounding cable with crimped terminal between the M3 screw and shakeproof washer as shown below and tighten the screw. Shakeproof washer Grounding cable (with crimped terminal) M3 screw Caution The cable with crimped terminal and shakeproof washer must be prepared by the user.
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
) M2 M3 M1 M2 1.25 1.68 Slide 12 3 0.53 0.70 Ball bushing 3.34 4.25 Slide 16 7 1.53 2.11 Ball bushing 11.4 17.1 Slide l l 20 12 5.60 7.28 Ball bushing Note) For the purpose of calculating the moment, the length of the arm is the distance that is measured from the guide shaft center ( mark).