SMC Corporation of America
Elite Part Number Search
Search Results "PF2W504T-03-1"

AL Standard Specifications AL30 AL40 AL60 AL10 AL20 AL40-06 AL50 Model 1/4, 3/8 Port size 1/4, 3/8, 1/2 1 M5 x 0.8 1/8, 1/4 3/4 3/4, 1 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa 1/4: 30 3/8: 40 1/2: 50 135 Note) 1/4: 30 3/8: 40 Minimum dripping flow rate (/min (ANR)) 220 4 15 50 190 Oil capacity (cm3) 55 135 7 25 135 135 Recommended lubricant Class 1 turbine oil (

Port size 02 1/4 03 3/8 Porting specications Nil Side ported B Bottom ported Note) Note) For bottom ported, port size is 1/4 only. 451

30 to 60C) 1 4 8 3 Note) AQ1500 and AQ1510 are not available. 3 4 Type Port size Symbol 0 5 Type Applicable model Diaphragm Lip AQ2 to AQ5 AQ1 Only Port size Applicable series M5 01 02 03 04 06 M5 x 0.8 AQ1500 AQ1510/2000 AQ2000/3000 AQ3000 1 8 Standard 1 4 0 1 M5 x 0.8 8 3 1 8 Note) AQ150 only 1 2 AQ5000 3 4 Thread type Metric thread (M5) Rc NPT G Nil N F Caution Be sure to read before handling

Tubing Size Symbol Type Body Class Tubing outside diameter Metric size 4 04 6 06 8 08 10 10 1/8 03 3/16 05 1/4 07 3/8 11 1/2 13 3 J Inch size Table 2. AC Insert Pin. Holder Assy Model Number LQ-GPJ LQ-GPJ-N LQ-GPJS LQ-GPJS-N LQ-GJLQ-GJ-NLQ-GJSLQ-GJS-NLQ-GC Larger Diameter Tubing How To Order LQ GC Nil B None With bracket Type Table 1.

G) S With sealant (for R) * R thread type: With sealant G thread type: Without sealant Valve side Port size Cylinder side 01 1/8 02 1/4 03 3/8 Cylinder side Valve side applicable tubing O.D.*1 06 6 08 8 10 10 With One-touch fittings *1 For selecting applicable tubing O.D., refer to the cover page. 1

NFC Reader/Writer 1 USB extension cable (2.95 m) 1 Operation Manual (this document) 1 Downloading and Installation of the driver software Downloading and installation of the driver software Downloading the driver software Obtain the driver software for the NFC reader/writer from the SMC website (https://www.smcworld.com).

Display accuracy 2% F.S. 1 digit or less (at ambient temperature of 25 3C) Operation indicator light Green LED (OUT1: Lights when ON), Red LED (OUT2: Lights when ON) Output voltage: 1 to 5V Output voltage: 1 to 5V 2.5% F.S. or less (in rated pressure range) 5% F.S. or less (in rated pressure range) Linearity: 1% F.S. or less Analog output (Note 2) Linearity: 1% F.S. or less Output impedance

Terminal thread type is M4. 0 W 1 03 1 0 ISG Mounting/Piping Caution Multipurpose pressure switch 1. Mounting is possible in either horizontal or vertical orientations. Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.

Refer to page 643 for replacement method. 02 1/4 03 3/8 Nil Rc N NPT T NPTF F G Note) For bottom ported, port size is 1/4 only. 611

I-67L iJ-26L 1i1-26L Pressure setting -1 OOkPa~ 1OOkPa !

TMH M5 Port size ASD M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Applicable tubing O.D. Note) Type 01 02 03 04 Inch size Metric size Elbow Universal 2 3 1/8" AS 23 01 3.2 03 05 07 09 11 13 04 06 08 10 12 4 5/32" 6 3/16" Control AS-FE U10/32 N01 N02 N03 N04 8 1/4" Meter-out Meter-in 0 1 10 5/16" Made to Order Refer to the below for details.

Example)AC30-F03DM-KSTV-13NR-A q r t y w e q Symbol Bodysize Description 20 25 30 40 Rc NPT G Nil N F Threadtype w + 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 Portsize e + Floattype autodrain a Withoutautodrain N.C.(Normalclose)Drainportisclosedwhenpressureisnotapplied. N.O.(Normalopen)Drainportisopenwhenpressureisnotapplied.

5 6 100 V 200 V 110 V 220 V 240 V 48 V 230 V 24 V 12 V 02 (1/4) 03 (3/8) 02 (1/4) 03 (3/8) Table (2) Solenoid Valve Option AC Note) Note) Seal material Body material/ Shading coil material Note Note) Guide pin material Main valve poppet Coil insulation type Option symbol Fixed sealant Nil C37 Stainless steel Stainless steel DC NBR NBR G Note 1) Option S, Z are not available as surge

Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.

Series ACG How to Order ACG 30 A 03 G1 Option Symbol Description Applicable model Body size Nil 1 2 3 6 8 C J N R ACG20 to 40 Port size Symbol (8) 0.02 to 0.2 MPa setting ACG20 to 40 20 30 40 1/8 Metal bowl ACG20 to 40 3/8 Lubricator with drain cock ACG20 to 40 1/2 Nylon bowl ACG30, 40 Metal bowl with level gauge ACG20 With bowl guard Model combination ACG20 to 40 (9) Filter case with drain

M or more (500 VDC measured via megohmmeter) between terminals and housing 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Note 1) In the case of PF2W711, 3% of F.S. or less (15C to 35C, 25C reference).

Symbol Body class 2 3, 4, 5, 6 3, 4, 5, 6 Thread type M5 Rc 1/8 NPT 1/8 Nil N Variations Model LVC20 LVC30 LVC40 LVC60 LVC50 Orifice diameter 4 8 10 22 16 Tubing O.D. Inch sizes Metric 3, 4, 6 6, 8, 10 10, 12 19, 25 12, 19 03 05 07 11 13 19 25 1/8 3/16 1/4 3/8 1/2 3/4 1 Inch Valve type Symbol Type 1/4, 3/8 3/8, 1/2 3/4, 1 1/2, 3/4 1/8, 3/16, 1/4 Basic type N.C. PB PA PA N.O.

Double acting Double acting 03 04 06 08 10 12 19 25 3 4 6 8 10 12 19 25 With flow rate adjustment PA N.C. B A N.C. Double acting With bypass PA PA N.C. PB B A B A Inch sizes Double acting 03 05 07 11 13 19 25 1/8 3/16 1/4 3/8 1/2 3/4 1 N.C. Double acting N.C. With flow rate adjustment & bypass PA B A N.C. N.C. With indicator PA Basic size With reducer N.C.