Not included for options Z and Z1. 20: 200V type manufactured befor August 2019 (Serial:XV) can not be set below 10. 21: 200V type manufactured befor August 2019 (Serial:XV) can not be set below 5S/cm. 9.1 Specifications HRR Series 9-2 HRX-OM-W002 Chapter 9 Documents 9.1.2 HRR012/018/024/030-W-10/20-* Table 9-2 Specifications [HRR012/018/024/030-W-10/20-*] Model HRR012-W-10-* HRR018-W-10-
(when maintenance signal is ON) During operation Maintenance detection operation Stop ion dischargeOFF Stop ion dischargeON Maintenance detection signal ON Stop operation Operate Stop operation Power OFF Power ON Stop ion dischargeOFF Indication on the panel Maintenance detection complete Contaminated Signal name Status Power ON Detecting Note 1) Operate Operate ON Power supply 24 VDC 5s
Time to reach 2000r/min is the acceleration/deceleration time constant of 5s or less. Speed is 150r/min or higher. The ratio of load inertia moment to servo motor inertia moment is 100 times or less. The acceleration/deceleration torque is 10% or more of the rated torque.
5s fitting assembly is included. The housing assembly and SI unit of F/P/J/G/S kit are not included. Separately place an order for q, w, e, and r. For Dusttight/Low jetproof type (IP65), please consult with SMC. Nil R S Common EXH External pilot Built-in silencer, direct exhaust Note 3) i U side end plate assembly no.
If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors' inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min Max . operating time 2min 1min 30s 20s 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600 700 1000 1500 2000 3000 4000 Current (% of rated current) Operating characteristics
HRZ010-W2SF MAX MIN MIN HRZ010-WS-F HRZ010-W1S-F HRZ010-W2SF Current (% to the capacity of the main breaker of this product) Figure 3-6 Breaker operating characteristics curve HRZ Series 3.3 Procedure for Installation 3-9 3-9 HRX-OM-X010 Chapter 3 Transporting and Installation HRZ008-L-F HRZ008-L1-F 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX MAX 2min 1min Operating time 30s 20s 10s MIN 5s
If the breaker with shorter operating time is connected, the customers equipment could be cut off due to the inrush current of the motor of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX 2min 1min 30s 20s Operating time 10s 5s MIN 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 130 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% to the capacity of the main breaker of this
Front matter 39 Series CRQ2X/MSQX Low-Speed Rotary Actuator CRB2 CRBU2 CRB1 MSU Realized a stable motion at 5s/90.
If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Operating characteristics
5s fitting assembly is included. Note 2) The housing assembly and SI unit of F/P/J/G/S kit are not included. Separately place an order for q, w, e, r. Common EXH External pilot Direct EXH outlet with built-in silencer Nil R Note 1) S Note 1) Note 3) S (Built-in silencer) and W (IP65) cannot be combined. Note 1) When both options are specified, indicate as RS.
5s fitting assembly is included. Note 2) The housing assembly and SI unit of F/P/J/G/S kit are not included. Separately place an order for q, w, e, r. Common EXH External pilot Direct EXH outlet with built-in silencer Nil R Note 1) S Note 1) Note 3) S (Built-in silencer) and W (IP65) cannot be combined. Note 1) When both options are specified, indicate as RS.
If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Operating characteristics
If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Operating characteristics
Pressure Control Equipment Regulator O-ring Exploded view Body A Clip Industrial Filters 449 Series ARM5A/5B/5S Replacement Procedure of Diaphragm 2 2.
If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Operating characteristics
If it is a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Breakers operating characteristic
5s fitting assembly is included. Note 2) The housing assembly and SI unit of F/P/J/G/S kit are not included. Separately place an order for q, w, e, r. Common EXH External pilot Direct EXH outlet with built-in silencer Nil R Note 1) S Note 1) Note 3) S (Built-in silencer) and W (IP65) cannot be combined. Note 1) When both options are specified, indicate as RS.
If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Operating characteristics
currents of this product. 4h 2h 1h 10min 14min 20min 30min 4min 6min 2min 1min 30 s Operating time 20 s 10 s 5 s Max. 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 600 5000 7000 Current (% for breaker capacity) For HRS090--20-B, HRS090--404h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s
If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Operating characteristics