screws (3 pcs with nominal diameter of 3.0) ZS-33-R DIN rail mounting parts -12No.PF-OMO0005-F Summary of Product parts Body Name Description Display 1 See below.
KF ) Fn J H B A G A mm A B C D E Fn G H J XLC-16 40 110 38 1 30 17 40 26 XLC-25 50 120 48 1 12 40 26 39 27.5 XLC-40 65 171 66 2 11 55 41 63 36 9 XL-OMV0002 4-2.162580,100,160 C E D C E E (KF ) (K ) Fn Fd J K H B A G A mm A B C D E Fn Fd G H J K XLC-50 70 183 80 31 10.5 75 52 77 29 10.5 XLC-63 88 209 100 39 11 87 95 70 76.5 36 9 XLC-80 90 250 117 45.5 11 114 110 83 105 44 9 XLC-100 108 317.5
Air operated style fluid control valve Vacuum valve Vacuum pad 2(A) 1(P) 2(A) 1(P) 2(A) 1(P) 2(A) 3(P) 3(R) 3(R) 3(R) 1(R) Atmospheric air or micro pressure for vacuum release 22 Multi-purpose Valve Series VCA Direct Operated 2 Port Solenoid Valve for Air Improved durability (Nearly twice the life of the previous series) Operating resistance of moving parts reduced for improved longevity
Load Mass Allowable Moment E-MY2H/M1 E-MY2H/M3 E-MY2H/M2 E-MY2H/m3 60 60 50 60 60 50 50 50 40 40 30 30 30 30 q r w et 20 20 20 20 Load Mass (kg) Moment (NNm) Moment (NNm) Moment (NNm) 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 MY2H16 4 4 4 4 3 3 3 3 MY2H16 MY2H16 2 2 2 2 MY2H16 0.2 1 1 1 100 200 300 400 500 1000 1500 1 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200
Built-in strong magnet Clevis width: 28 mm Auto switch Without auto switch (Built-in magnet) Without switch mounting rod Without auto switch (Built-in magnet) With switch mounting rod D-P3DWASC D-P3DWASE D-P3DWAL D-P3DWAZ D-P4DWSC D-P4DWSE D-P4DWL D-P4DWZ D-P79WSE D-P74L D-P74Z Nil Bore size 80 100 80 mm 100 mm P P3DWASC P3DWASE P3DWAL P3DWAZ P4DWSC P4DWSE P4DWL P4DWZ P79WSE P74L P74Z CKGA
Switches D-A73.D-A73H D-A76H D-A72, D-A72H comact pror6ctiv6 iifrffi I co.'rua i Lishl 'ni'ng dr.d iFolec''v r-o'" . --{%!fi; ,Ek---
D-J79C, D-F7BV D-F79.D-F7NV l--;;;-;-l .."e D-F7P. D-F7PV .r_ i Frod i i l r E . l I I 19* i --r ,-t o'rp'r _T_ 5*"" I whhe !t, I L l i o -J Alack D-J79W. D-F7BWV D-F7PW D-F79W. D-F7NWV l-ffis". l 1 1 I l R d t l a / f l lEljJl l,." i w,,te I I i. +-| I T f I i L t > . O L4J==L=!
Applicable cylinder series CKP140-100 63 50 40 CKP140-125 BK1T-040 D-P4DWSC D-P4DWSE D-P4DWL/Z CKP140-150 Series CKG1 CKG140-50 CKG150-50/CKP150-50 CKG163-50/CKP163-50 CKG140-75 CKG150-75/CKP150-75 CKG163-75/CKP163-75 CKG140-100 CKG150-100/CKP150-100 CKG163-100/CKP163-100 CKG40-R050 Series CKP1 BAP1T-040 D-P79WSE D-P74L/Z Series CKG140/50/ 63 CKG40-R075 CKG40-R100 Series CKP150/63 CKG140-
to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9
D-R Note 3) Options for 2, 6, and 8 can not be specified at the same time. (Ex.) 68 Note 4) Symbols 9, D, J can not be specified at the same time. (Ex.) 9-D-J Note 5) For products with auto drain, either symbol D or J cannot be specified at the same time because of female threads (3/8 or 1/8), for connection to drain piping.
DITENSIONS A B c D E F o H J t( T N o P B s r u 3.43 (87) 2.
. 0: 0.1 1: 1 2: 10 3: 100 UAC (Accumulated minimum unit for connection product [USEr]) Y U8 0x01 12 R/W (1) Set the accumulated volume per pulse when the user's additional range is selected. 0: 0.1 1: 1 2: 10 3: 100 UPLS (Accumulated volume per pulse for connection product [USEr]) Y U8 0x02 13 R/W (2) 0: L 1: oC 2: Ft 3: GAL 4: F 5: oFF 14 R/W Unit setting (USEr is selected) Y U8 0x00 (0
A 5 SMC 1 K L M E F 3 12 12 12 12 G 12 N SMC SMC O P SIDE U SIDE D n 3 STATION 2 1 4 NOTES: 1) SIZE 1 1/4, 3/8,1/2 SIZE 2 3/8, 1/2,3/4 SIZE 3 3/4, 1 6 PORTS, 1, 3,5 PORTS 2) SIZE 1 1/4, 3/8,1/2 SIZE 2 3/8, 1/2,3/4 SIZE 3 1/2, 3/4,1 2 PORTS, 2, 4 PORTS 3) ALL DIMENSIONS ARE IN MILLIMETERS SMC SMC BB CC 2 2 2 2 AA S R Q 4 4 4 4 U T X Y Z V W PITCH NOTE #2 Q 81 R 49 5.5 S A 177.5 B 119 C 9 D
IC circuit, Relay, PLC Applicable load 24 V AC/DC or less Load voltage 48 V AC/DC or less 100 V AC/DC or less Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None 1 or less (including lead wire length of 3 m) Internal resistance D-A93/D-A93V/D-A96/D-A96V (with indicator light) D-A93/D-A93V D-A96/D-A96V Auto switch part no.
Basic inertia moment 2 r m I m : Weight of load (kg) r : Load center of gravity and distance of rotation axis. (m) r m Fig. (10) Inertia moment This shows inertia moment of m (weight) at r from the rotation axis. Calculation of inertia moment depends on the shape of the object.
CE marking D-A93, D-A93V, D-A96, D-A96V (With indicator light) Precautions Caution D-A96, D-A96V D-A93, D-A93V Auto switch model Applicable load IC circuit Relay, PLC 24 VDC Load voltage 100 VAC 4 to 8 VDC Fix the auto switch with the existing screw installed on the auto switch body.
Mounting angle view (-R specification) MPa OUT IN K P C U O S L H to 2 Air Combination Series ACG Accessory/Optional Combinations : Combination available : Combination not available : Varies depending on a model : Available only with NPT thread F.R.L. unit applicable model Combination Option Accessory Symbol D 1 2 3 6 8 J C N R W ACG20 ACG20C ACG20A ACG20B ACG20D ACG30 to to to ACG30C ACG30A
to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9
Note 7) In case of an external pilot "R", indicate external pilot specification "R" for the applicable valve also. B3 Stations B4 D side B6 B5 LM Note) Stations are counted starting from station 1 on the D side. Note 1) Indicate CM and LM in the specification table. Note 2) Inch sizes use the following symbols.