SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-T-P-N02-WY"

Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 40µ, Water Removal Type: Large Flow Type, Semi-standard: 6 + R + Z

Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 40µ, Water Removal Type: Large Flow Type, Semi-standard: Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F)

Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 5µ, Water Removal Type: Large Flow Type, Semi-standard: 6 + R + Z

Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 80µ, Water Removal Type: Large Flow Type, Semi-standard: 6 + R + Z

Body Size: 30, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 5µ, Water Removal Type: Large Flow Type, Semi-standard: Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F)

Body Size: 40, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 5µ, Water Removal Type: Large Flow Type, Semi-standard: Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F)

Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 80µ, Water Removal Type: Large Flow Type, Semi-standard: Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F)

Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 80µ, Water Removal Type: Large Flow Type, Semi-standard: 6 + Z

Body Size: 40, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 80µ, Water Removal Type: Large Flow Type, Semi-standard: 6 + Z

Body Size: 40, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 5µ, Water Removal Type: Large Flow Type, Semi-standard: 6 + Z

Body Size: 40, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 80µ, Water Removal Type: Large Flow Type, Semi-standard: Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F)

Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 5µ, Water Removal Type: Large Flow Type, Semi-standard: 6 + Z

Body Size: 30, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 5µ, Water Removal Type: Large Flow Type, Semi-standard: 6 + Z

Body Size: 40, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 5µ, Water Removal Type: Large Flow Type, Semi-standard: R + Z

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: Operation Manual, Calibration Certificate

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter for w/o Flow Adjustment

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter

Not Provided] No, Pressure Gauge: [None (Pressure Port Plug Available)] No Pressure Gauge, Size of Body: 20, Check Valve: None, Pressure Switch: None, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: 0.05 to 0.85 MPa, Drain Outlet: N/A, Lubricator Oil Discharge Outlet: Without drain cock, Pressure Unit: Name plate, bowl caution plate and pressure gauge units: psi, °F, T