Apply an appropriate tightening force during mounting.
level gauge B B B B B B B Dimensions B Barb fitting Applicable tubing: T0604 Model Standard specifications Optional specifications Bracket mount P M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 A 25 40 53 70 75 90 95 B 77 115 142 176 176 250 268 C 26 36 38 40 38 41 45 D 12.5 20 26.5 35 35 45 47.5 E 30 38 38 45 G 35 60 80 110 110 110 110 J 12.5 20 26.5 35 35 45 47.5 M 30 41 50
seal A Urethane 56 20 Same as cushion seal A except for 20, 25 standard strokes Steel ball B Carbon steel 21 Cushion seal B Urethane 57 Tooth ring Stainless steel 22 Damper Urethane Cushion ring gasket A NBR 58 23 Same as cushion ring gasket A except for 20, 25 standard strokes C type snap ring for taper ring Carbon steel 24 Cushion ring gasket B NBR 59 C type snap ring for unlocking cam
absorber and stroke adjustment range from 5mm to 15mm 8 12 16 20 25 8 12 16 20 25 4 + Add B Note 1) When only one side of stroke is changed, the quantity needed is the half of the above.
Auto Switch Proper Mounting Position for Stroke End Detection MY1CW 16, 20 MY1MW 16, 20 B A Reed switch D-A90(V), D-A93(V), D-A96(V) Solid state switch D-F9N(V), D-F9P(V), D-F9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) Mounting position 20 16 20 16 20 Mounting position Mounting position 16 A 90 70 93 73 94 A A 74 B 110 90 107 87 106 B B 86 Operating range Note) 7.5 11 6.5 8.5 6.5 Operating range
Setting Position (mm) D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, A34 D-A44 D-B5 D-B6 D-H7l D-H7C D-G5NTL D-H7lW D-H7lF D-H7BAL D-B59W Bore size (mm) A B A B A B A B A B A B A B 20 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 25 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 32 59.5 36.5 53.5 30.5 58.0 35.5 55.0 32.5 57.0 34.0 56.5 33.5 53.0
VHS One-handed operation Two-handed operation Clamping Press fitting with an air cylinder, Caulking Application Examples 1681 Two Hand Control Valve VR51 Series RoHS How to Order VR51 B C06 Option Two hand control valve Nil B None With bracket Silencer (Accessory) Connection piping size Flame resistant One-touch fitting C06 C07 Flame resistant One-touch fitting 6 Flame resistant One-touch
W .TOea TT XIUS ' Z ZZ l ~/ t ~ ~ 20 27 Y. 42 11 20 45 153 8 15 !
When option parts are required separately, use the following part numbers to place an order. Option Part No. Note Bracket B and the bracket assembly make up one set.
F N N C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B Cylinder tube sectional view B-B Stroke range Bore size (mm) Width across flats Effective thread length C B G F E A V W H ZZ S P N MM J MB 32 40 50 63 80 100 9 6.5 13 14 15.5 16.5 19 19 13 13 14 14 20 20 30
F N N C B Cylinder tube sectional view B-B Stroke range Bore size (mm) Width across flats Effective thread length C B G F E A V W H ZZ S P N MM J MB 32 40 50 63 80 100 9 6.5 13 14 15.5 16.5 19 19 13 13 14 14 20 20 30 35 40 45 45 55 32.5 38 46.5 56.5 72 89 46 52 65 75 95 114 22 30 35 35 40 40 47 51 58 58 72 72 135 139 156 156 190 190 84 84 94 94 114 114 1/8 1/4 1/4 3/8 3/8 1/2 26.5 26.5 31
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.
20 20 20 20 20 20 20 9.5 9.5 9.5 11.5 D-F7, F7V D-J79, J79C D-F7W, F7WV D-J79W D-F7BAL, F7BAVL D-F7NTL, F79F D-F7W D-J79W D-F7BAL D-F79F D-F9BAL 6 6 6 6.5 Number of auto switch D-F7LF D-A9 D-F9 D-A79W 7.5 7.5 8 D-F7LF 7.5 D-F9, F9V D-F9W, F9WV D-F9BAL 1 pc. 2 pcs. 20 20 20 20 25 25 20 20 5.5 5.5 5.5 6.5 The operating ranges are provided as guidelines including hystereses and are not guaranteed
Push Button (Mushroom)/VM120-01-30R, B, G, Y/VM130-01-30R, B, G, Y Panel mounted hole JIS Symbol 2 port 3 port 21N F.O.F. 0.5MPa supply 4.9mm P.T. 1.6mm O.T. 6.5mm T.T. Push Button (Extended)/VM120-01-32R, B, G, Y/VM130-01-32R, B, G, Y Panel mounted hole JIS Symbol 2 port 3 port 21N F.O.F. 0.5MPa supply 4.9mm P.T. 1.6mm O.T. 6.5mm T.T.
S Z Nil 14 1 2 1 20 2 Indicator light is not available for grommet type.
D-F9WV D-F8 Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E 18.5 31 6.5 20.5 41 8.5 20.5 33 4.5 17 20.5 31 4.5 15 20.5 41 4.5 15 20.5 51 4.5 35 22.5 43 6.5 27 22.5 33 6.5 17 22.5 43 6.5 27 22.5 53 6.5 37 MIW12-12D MIW20-20D 6 4 4 2 18.5 29 6.5 20.5 31 8.5 MIS12-10D MIS20-10D 4 2 6 4 2.5 4 18.5 39 6.5 20.5 41 8.5 MIS12-20D MIS20-20D 6 4
U D-A79W D-F7WV D-F7V D-F7BAVL A B A B Proper auto switch mounting positions (mm) D-A7H, D-A80H D-A73C, D-A80C D-F7 D-F7V D-F7W, D-F7WV D-J79 D-J79C, D-J79W D-F7BA D-F9 D-F9V D-F9W D-F9WV D-A7 D-A80 D-A9 D-A9V D-F7F D-F9BAL D-A79W D-F7NTL Bore size (mm) A B A A A A B A A A B B B B B B 20 20.5 11.5 21 18 25 26 12 9 16 17 32 27 20 27.5 24.5 31.5 26 19 30 29 32.5 20.5 17.5 24.5 23 22 25.5
If foreign matter is adhering to the parts, perform an appropriate procedure, such as blowing with air or cleaning with neutral detergent. Closing the valve: Turn 90 counterclockwise from the open state to the original state to close the valve. Perform an eletrical operation at the position where the valve is closed.