SMC Corporation of America
Elite Part Number Search
Search Results "GZ46-K-01-C"

1/8 (A port) 18 8.5 2 x 4.5 (For mounting) 4 34 Manual override A 24 P R 33.5 G: Approx. 300 H: Approx. 600 (Lead wire length) 55.6 [57.8] (Light/surge voltage suppressor) 49.6 [56.6] + 34.2 8.5 16.5 21 X 6 32 24 15 17 9 1/8 (P, R port) 42 L plug connector (L): 10-SYJ54M-L-01 M plug connector (M): 10-SYJ54M-M-01 DIN terminal (D, Y): 10-SYJ54MD Y-01 M8 connector (WO): 10-SYJ54M-WO-01 Approx

Alarm_Co mment_1 11 (01-111) 6F C RESET Input The motor speed exceeds a specific level due to an external force, etc. Speed exceeded set value (01-144) Make improvements so that the motor speed will not exceed the maximum speed of the actuator.

Alarm_Co mment_1 11 (01-111) 6F C RESET Input The motor speed exceeds a specific level due to an external force, etc. Speed exceeded set value (01-144) Make improvements so that the motor speed will not exceed the maximum speed of the actuator.

The Drive operation [DRIVE] is ON when servo [SVRE] is OFF (01-098) off ALM C RESET Servo input Command operation while the servomotor is on (SVRE output is on).

SYJA524-01 SYJA712-01 SYJA722-01 SYJA714-01 SYJA714-02 0.76 0.69 0.69 0.66 0.63 0.64 0.51 0.42 0.34 0.33 0.45 0.48 2.5 2.4 2.7 2.6 2.3 2.3 0.77 0.72 0.71 0.74 0.70 0.68 0.43 0.38 0.32 0.31 0.21 0.31 2.8 2.7 2.9 3.0 2.8 2.7 N.C. N.O. Rc 1/8 Body ported 80 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 M5 x 0.8 130 (Without subplate 80) N.C. Base mounted (with sub-plate) SYJA724-01 SYJA724-02 N.O.

(Manifold base) SYJ7120-5G-01 2 pcs. (Valve) SYJ7000-21-1A 1 pc. (Blanking plate assembly) SS5YJ7-41-03-01 1 pc. (Manifold base) SYJ7140-5LZ 1 pc. (Valve) SYJ7240-5LZ 1 pc. (Valve) SYJ7000-21-1A 1 pc. (Blanking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

1MPa = 145 psi F = (1.8 x C) + 32 4 Clean One-Touch Fittings Series KP How to Order KP H 06 KP P 08 01 Applicable fitting size Port size/Applicable tubing O.D.

1MPa = 145 psi F = (1.8 x C) + 32 4 Clean One-Touch Fittings Series KP How to Order KP H 06 KP P 08 01 Applicable fitting size Port size/Applicable tubing O.D.

B RESET >+JOG (01-052) >+B RESET 65 - 112 12 0 2 3 4 5 6 7 Alarm _Comment _058 (01-058) 3A B RESET No.base PLC <> 1 1ABS 2INC 2PLC 2 14.2[2] (P.54) Alarm _Comment _061 (01-061) 3D B RESET <>+ <>+Alarm _Comment _062 (01-062) 3E B RESET <> (01-096) C RESET <> (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON SVRE ON DRIVE ON (01-099) <> SET OFF

(PLC ) Alarm _Comment _061 (01-061) <> (1) ()1(ABS)2(INC) (2)PLC 15ms(30ms) 13.2[2](P.53) 3D B RESET (+)(-) Alarm _Comment _062 (01-062) (+)(-) 3E B RESET <> (01-096) C RESET <> -64- (01-097) <> C RESET <> <>OFF JOG OFF (01-098) OFF DRV C RESET <>ON (SVRE ON) DRIVE ON (01-099) <> SET OFF DRV C RESET <> <>12 (01-103) C RESET 1 [] A [a ] 2 [SW] [] A [a ] <> <>

Flow Characteristics Flow characteristics Port size 14/2 (PA/B) 4/25/3 (A/BR) Manifold C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 1(P), 5/3(R) Port 2(B), 4(A) Port Type SS5YJ7-21P-01 1/4 1/4 1/4 2.1 1.4 1.8 0.36 0.32 0.37 0.55 0.36 0.50 2.3 2.1 2.1 0.26 0.24 0.20 0.54 0.50 0.50 1/8 C6 C8 Body ported Type SS5YJ7-21P-C6 SYJ723 for internal pilot Type SS5YJ7-21P-C8 Note) Value at manifold base

Inch Size [mm] Model d T (R, NPT) H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) M W1 W2 X Y Weight [g] Unlocked Locked Unlocked Locked AS221FS-01-01 (S) 1/8" 7.2 12 19.1 26.2 19.1 43.9 42.4 40.8 39.3 13.3 20 21.5 6.5 15 13 (13) AS221FS-01-03 (S) 5/32" 8.2 AS221FS-01-07 (S) 1/4" 11.2 20.8 27.9 14 (13) AS221FS-01-09 (S) 5/16" 13.2 22.4 29.5 14.2 15 (14) AS221FS-02-01 (S) 1/8" 1/8 13 (12.7) 7.2 20.9

(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRS100/150 Series 5-20 HRX-OM-S010 Chapter 5 Simple communication

-D-01 C6: MAX. 6 C8: MAX. 6.5 MAX. 10 2-One-touch fitting (A, B port) Applicable tubing model C6: T0604 C8: T0806 Applicable cable O.D. 3.5 to 7 3-3-57 Series VZ5000 2 Position Double VZ5220 Grommet (G), (H) VZ5220-01 G H Manual override (Non-locking) (Mounting hole for manifold) (Lead wire length) G: 300 mm H: 600 mm (Mounting hole) (PE port) (Piping port) L plug connector (L) VZ5220-L-01

connector (L): SYJ5140-L-01 M plug connector (M): SYJ5140-M-01 DIN terminal (D): SYJ5140-D-01 M8 connector (W0): SYJ5140-W0-01 Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 82.9 82.6 Max. 10 75.4 50.1 [57.1] 64.1 34.7 54.6 M8 x 1 49 37.1 61.2 [68.2] Approx. 300 (Lead wire length) 6 Pg7 6 6 6 73.5 [75.7] 63.7 [65.9] 83.5 65.2 72.6 58.7 0.5 45.5 45.5 45.5 45.5 17 17 17 17 17

(Size: 01) EVS1-02 (Size: 02) 100 80 1000 l/min (ANR) 400 l/min (ANR) Accommodates enclosure IP65 Dust/Splashproof type Lightweight Size 01 (3 position): 0.26 kg Size 02 (3 position): 0.18 kg 3-11-11 12 ISO Standard Solenoid Valve Size 1,2/Single Unit Series EVS1-01/1-02 How to Order FG S EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 Courtesy of Steven Engineering

BK RLS 0V M 24V C 24V EMG BK RLS Lock release (+) The positive power for lock release.

(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRS090 Series 5-20 HRX-OM-T004 Chapter 5 Simple communication