SMC Corporation of America
Elite Part Number Search
Search Results "25A-VHS40-04B"

Shock absorber type: basic or with cap; Applicable thread O.D. size: M8, M10, M14, M20, M27; Option: stopper nut; Series 25A-RB/C is compatible with secondary battery applications

Controls air pressure in proportion to an electric signal; Available in MPa, kgf/cm², bar, PSI, and kPa units; Pressure range of 0.005 to 0.9MPa; Available port sizes 1/4, 3/8 and 1/2; Mounting bracket option; Series for 25A-ITV is compatible with secondary battery applications

Base mounted, plug-in type manifold for VQ2*0* valve; D-sub connector (25 pin standard, 15 pin option); Top or side receptacle position; Maximum 24 stations available as standard; 12 port sizes available; Optional DIN rail mount; Series 25A-VV5Q2 is compatible with secondary battery applications

Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications

Bore sizes: 6, 8, 12, 16, 20, 25 mm; Stroke adjuster options: rubber or metal stopper; End lock option in the event of air pressure loss; Auto switch capable; Series 25A-MXQ is compatible with secondary battery applications

Bore sizes: 6, 10, 16, 20 mm; Special (non-standard) porting option; Rubber bumpers; Auto switch capable; Series 25A-MXH is compatible with secondary battery applications

Bore sizes: 6, 10, 16, 20, 25, 32, 40 mm; High repeatability: ±0.01 mm; Dust covers: chloroprene rubber, fluororubber, silicone rubber; Option for NSF-H1, food grade lubricant; Auto switch capable; Series 25A-MHZJ2 is compatible with secondary battery applications

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.  25A-PFMB7201 is a digital flow sensor compatible with air and nitrogen.  Its thermal sensor is protected in a bypass flow path to reduce contact with moisture and contaminants, avoiding accuracy deterioration and damage. 

Miniature free mount; Space saving compact cylinder; Available in 6mm to 20mm bore size; Series 25A-CUJ is compatible with secondary battery applications

Bore sizes (mm): 6 10, 15, 20, 25, 32; Stroke lengths up to 100mm; Auto switch capable; Series 25A-CXSJL is compatible with secondary battery applications

Bore sizes: 6, 8, 10, 12, 16 mm; Non-rotating accuracy +/-0.03° for 6, 8, 10 mm bore; Non-rotating accuracy +/-0.04° for 12, 16 mm bore; Stroke adjuster options: rubber, metal stopper or shock absorber; Auto switch capable; Series 25A-MXP is compatible with secondary battery applications

Bore sizes: 6, 8, 12, 16, 20 mm; Repeatable positioning accuracy: +/-0.05 mm; Stroke adjuster options: rubber, metal stopper or shock absorber; Auto switch capable; Series 25A-MXQ*B is compatible with secondary battery applications

Bore sizes: 8, 12 mm; Repeatable positioning accuracy: +/-0.05 mm; Stroke adjuster options: rubber, metal stopper or shock absorber; End lock option in the event of air pressure loss; Auto switch capable; Series 25A-MXQ*C is compatible with secondary battery applications

Bore sizes: 6, 8, 12, 16, 20, 25 mm; Repeatable positioning accuracy: +/-0.05 mm; Stroke adjuster options: rubber, metal stopper or shock absorber; End lock option in the event of air pressure loss; Auto switch capable; Series 25A-MXQ*A is compatible with secondary battery applications

The 25A- series variations are designed using material compatible with secondary battery applications and are able to be used in low dew point environments.  The variations eliminate copper (Cu) and zinc (Zn) material where possible, making them compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.  25A-PFMB is a digital flow sensor compatible with air and nitrogen.  Its thermal sensor is protected in a bypass flow path to reduce contact with moisture and contaminants, avoiding accuracy deterioration and damage.

Improved handle ergonomics; Integrated gauge and pressure switch options; Mounting interchangeable with existing product; Bracket and set nut options for individual mounting; Rc, NPT, or theads; Series 25A-AR-D is compatible with secondary battery applications

Rods at both ends of cylinder; Bore sizes (mm): 12, 16, 20, 25; Strokes from 5mm through 50mm depending upon bore size; Mounts: through hole/both ends tapped, foot, flange; Variety of switches and a variety of lead wire lengths; Series 25A-CQSW is compatible with secondary battery applications

Integrated filter and regulator saves space and requires less piping; Improved handle ergonomics; Polycarbonate, nylon, and metal bowl options; Integrated gauge and pressure switch options; Mounting interchangeable with existing product; Rc, NPT, or G threads; Series 25A-AW-D is compatible with secondary battery applications

The 25A-SY series is designed using material compatible with secondary battery applications and are able to be used in low dew point environments.