ZB-OM00201-B Specifications General Specifications Ambient -5 to 50oC (No condensation) temperature range Fluid Air, inert gas Vibration 30m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 1) 20m/s2 (With switch) Impact 150m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 2) 100m/s2 (With switch) Note 1)
Fig.11 Component parts of MSUA1/3 switch unit No.
Additionally, note that the 12 VDC relay does not apply to the auto switch. -11- 11. Pay attention to leakage current. <2-wire type> Current (leakage current) flows to the load to operate the internal circuit even when in the OFF state.
Description Qty. 4 Seal 1 4 Seal 1 4 Seal 1 4 Seal 1 Parts included 11 Gasket 1 11 Gasket 1 11 Gasket 1 11 Gasket 1 12 Gasket 1 12 Gasket 1 12 Gasket 1 12 Gasket 1 in seal kit 16 Wear ring 4 16 Wear ring 4 16 Wear ring 4 16 Wear ring 4 17 Piston seal 4 17 Piston seal 4 17 Piston seal 4 17 Piston seal 4 Please refer to P19 to 21 for the product construction.
Accuracy: Basic Type, Size: 40, Motor Type: S2 (100W Output, Incremental Encoder), Lead, mm: B (Size 40: 8mm, Size 63: 10mm, Size 100: 10mm), Stroke: 300mm, Motor Option: None, Cover: w/o Cover, Cable Type: S (Standard), Cable Length: A (10m), Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input)
Accuracy: Basic Type, Size: 40, Motor Type: S2 (100W Output, Incremental Encoder), Lead, mm: B (Size 40: 8mm, Size 63: 10mm, Size 100: 10mm), Stroke: 300mm, Motor Option: None, Cover: w/o Cover, Cable Type: S (Standard), Cable Length: 2m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input)
Accuracy: Basic Type, Size: 40, Motor Type: S2 (100W Output, Incremental Encoder), Lead, mm: B (Size 40: 8mm, Size 63: 10mm, Size 100: 10mm), Stroke: 300mm, Motor Option: None, Cover: w/o Cover, Cable Type: S (Standard), Cable Length: 5m, Driver Type: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input), I/O Connector: H (Connector)
Accuracy: Basic Type, Size: 40, Motor Type: S2 (100W Output, Incremental Encoder), Lead, mm: B (Size 40: 8mm, Size 63: 10mm, Size 100: 10mm), Stroke: 300mm, Motor Option: None, Cover: w/o Cover, Cable Type: S (Standard), Cable Length: 5m, Driver Type: A2 (LECSA2-S, 200~230V Incremental, Pulse Input)
Accuracy: Basic Type, Size: 40, Motor Type: 100W Output, Incremental Encoder, Lead, mm: Size 40: 8mm, Size 63: 10mm, Size 100: 10mm, Stroke: 300mm, Motor Option: None, Cover: w/o Cover, Cable Type: Standard, Cable Length: 10m, Driver Type: LECSA1-S, 100~120V, Incremental, Pulse Input, I/O Connector: -, Option: -
Accuracy: Basic Type, Size: 40, Motor Type: 100W Output, Incremental Encoder, Lead, mm: Size 40: 8mm, Size 63: 10mm, Size 100: 10mm, Stroke: 300mm, Motor Option: None, Cover: w/o Cover, Cable Type: Standard, Cable Length: 2m, Driver Type: LECSA1-S, 100~120V, Incremental, Pulse Input, I/O Connector: -, Option: -
Accuracy: Basic Type, Size: 40, Motor Type: 100W Output, Incremental Encoder, Lead, mm: Size 40: 8mm, Size 63: 10mm, Size 100: 10mm, Stroke: 300mm, Motor Option: None, Cover: w/o Cover, Cable Type: Standard, Cable Length: 5m, Driver Type: LECSA1-S, 100~120V, Incremental, Pulse Input, I/O Connector: Connector, Option: -
Accuracy: Basic Type, Size: 40, Motor Type: 100W Output, Incremental Encoder, Lead, mm: Size 40: 8mm, Size 63: 10mm, Size 100: 10mm, Stroke: 300mm, Motor Option: None, Cover: w/o Cover, Cable Type: Standard, Cable Length: 5m, Driver Type: LECSA2-S, 200~230V Incremental, Pulse Input, I/O Connector: -, Option: -
12 26 15 4 Accessory option: Hexagon socket head screw (special screws) 7 2-2H9 +0.025 0 depth 2 3 3 7 11 11 Groove for auto switch mounting 2-M3 x 0.5 thread depth 4 Mounting thread 11 34 10 Series MHF2 Dimensions MHF2-8D2 Scale: 80% 2.5H9 +0.025 0 depth 2.5 17 17 17 2.5H9 +0.025 0 depth 2.5 3 3.4 64.3 4-M3 x 0.5 thread depth 7 Mounting thread 32 72 2-M3 x 0.5 thread depth 4 Mounting thread
P4 is selected by the ON/OFF combination of S1 and S2.
Install manually controlled equipment for safety when the actuator has to be reset to the starting position. (11) Do not use the product as a shock absorber.
Table 10 shows the part number of the special angle adjustment tool and Table 11 shows the dimensions of the special tool. Angle adjustment using the special tool Table 10. Part number of special angle adjustment tool Size Part number 10 P8910195 20, 30 P8910295 50 P8910495 Table 11.
-25S Single acting 25 11.9 (53) 22 19 41 19.9 MHKL2-12C 12 2.5 (11) 11 9 20 3.7 MHKL2-16C 16 4.9 (22) 14 14.6 28.6 5.9 L1 MHKL2-20C 20 9.0 (40) 18 16 34 11.1 L2 MHKL2-25C 25 14.2 (63) 22 19 41 19.9 Note) At the pressure of 72.5 psi (0.5MPa), when holding point L is 20mm.
Warning Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.
2 position single: VSA4140 2 position double: VSA4240 3 position closed center: VSA4340 3 position exhaust center: VSA4440 4-9 (11) Mounting hole 4-9 (11) Mounting hole 4-9 (11) Mounting hole ( ): Valve for Rc 3/4 5-3-36 7 Series VSA40 Manifold Specifications Specifications Valve manifold with the same body size Valve manifold with the same body size Value manifold with the different body
Warning Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.