SMC Corporation of America
Elite Part Number Search
Search Results "VV3P7-42-043-04N"

Model: 42 (Dual AC), Bar Length: 64 (640mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
High-voltage Power

Model: 42 (Dual AC), Bar Length: 100 (1000mm), Emmiter Cartridge, Material: M (High Energy Saving De-ionizing Cartridge, Silicon), High-voltage Cable Length: 3 (3m), One-touch Fitting: AH (ø10 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller

Model: 42 (Dual AC), Bar Length: 64 (640mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: N (None), Bar Bracket: F (w/Bracket 2)

Model: 42 (Dual AC), Bar Length: 16 (160mm), Emmiter Cartridge, Material: E (High Speed De-ionizing Cartridge, Silicon), High-voltage Cable Length: 2 (2m), One-touch Fitting: 7L (ø1/4" Elbow), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: F (w/Bracket 2), DIN Rail Bracket for Controller

Model: 42 (Dual AC), Bar Length: 28 (280mm), Emmiter Cartridge, Material: V (Energy Saving High-efficiency Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
High-voltage

Model: 42 (Dual AC), Bar Length: 58 (580mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 1 (1m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: N (None)

Model: 42 (Dual AC), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 5H (ø3/16" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller

Model: 42 (Dual AC), Bar Length: 160 (1600mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: BL (ø3/8" Elbow), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: N (None), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller

Model: 42 (Dual AC), Bar Length: 178 (1780mm), Emmiter Cartridge, Material: E (High Speed De-ionizing Cartridge, Silicon), High-voltage Cable Length: 1 (1m), One-touch Fitting: BL (ø3/8" Elbow), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 15 (15m), Bar Bracket: F (w/Bracket 2), DIN Rail Bracket for Controller

Model: 42 (Dual AC), Bar Length: 160 (1600mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: BL (ø3/8" Elbow), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: N (None), Bar Bracket: w/o Bracket, DIN Rail Bracket for Controller & <

Model: 42 (Dual AC), Bar Length: 64 (640mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 6H (ø6 Straight), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
High-voltage Power

Model: 42 (Dual AC), Bar Length: 46 (460mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 8H (ø8 Straight), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 5 (5m), Bar Bracket: B (w/Bracket 1)

Model: 42 (Dual AC), Bar Length: 46 (460mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller & <

Model: 42 (Dual AC), Bar Length: 100 (1000mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 1 (1m), One-touch Fitting: 8H (ø8 Straight), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
High-voltage Power

Model: 42 (Dual AC), Bar Length: 160 (1600mm), Emmiter Cartridge, Material: V (Energy Saving High-efficiency Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: N (None), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for

Model: 42 (Dual AC), Bar Length: 82 (820mm), Emmiter Cartridge, Material: V (Energy Saving High-efficiency Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: N (None), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller

11 Mounting and Installation 13 Installation 13 SI Unit Model Indication and How to Order 16 Summary of Product parts 16 Mounting and Installation 17 Wiring 17 Setting and Adjustment 18 LED Display 21 Specifications 24 Dimensions 25 End Plate Model Indication and How to Order 26 Summary of Product parts 27 Mounting and Installation 29 Wiring 29 Specifications 31 Dimensions 32 Maintenance 42

No.EX-OMN0035CN-A / Series EX600-DX## EX600-DY## EX600-DM## SMC 3 9 10 12 12 14 17 17 20 20 LED 25 28 28 31 34 34 36 36 LED 40 42 42 44 46 46 48 48 LED 52 54 54 56 -1No.EX-OMN0035CN-A 57 58 58 58 58 58 59 -2No.EX-OMN0035CN-A (ISO/IEC)(JIS) 1 2 *1 ISO 4414: Pneumatic fluid power -General rules relating to systems.

(Linked to OUT1) -31No.PS-OMW0012-C [F 2] Setting of OUT2 Page 42 Item Explanation Default setting Output mode Either hysteresis mode, window comparator mode, error output or switch output OFF can be selected. Hysteresis mode Reversed output Selects which type of switch output is used, normal or reversed.

No.PF-OMJ0005CN-I () // PFM7## 2 10 13 14 14 16 17 20 22 22 F0 23 F1 OUT1 24 F2 OUT2 27 F3 28 F4 29 F5 30 F6 31 F7 32 F8 35 F9 36 F10 38 F11 39 F12 40 F13 41 F98 42 F99 44 45 49 50 53 54 54 57 59 73 -1No.PF-OMJ0005CN-I (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules