Model IDF4E/6E/8E/11E/15E1-10-R IDF15E1-20-R IDF4E/6E/8E/11E-20-R Item Rated current : (A) 10 5 Current sensitivity : (mA) 30 IDF Series 12-1 Safety instructions 121 IDX-OM-W010 Air Dryer 12 Specification for Option R 12-3 Power supply connection procedure 1) Take off the rear panel. 2) Insert the power cable prepared by the customer into the power code fixture and bring the power cable near
Ground Fault Circuit Interrupter To the users machine Terminal connecting screw: M5 Connector width: 9.5mm or less Applicable electrical wire: 1.25mm2 or more L ,N: Power supply N L Ground fault display button (white) test button (gray) 121 12. Specification for Option R 3) Connect the power cable to the terminal of the GFCI. 4) Connect the ground line.
Dryer model number Specifications of GFCI IDFA22E/37E/55E-23-R Rated current: 10A, Current sensitivity: 30mA IDFA75E-23-R Rated current: 15A, Current sensitivity: 30mA 12-3 Power supply connection procedure 1) Take off the front panel. 2) Insert the power cable prepared by the customer into the power code fixture and bring the power cable 12-1 Safety instructions 121 IDF Series IDX-OM-W025
L N PE To the users machine Terminal connecting screw: M3 Crimped terminal width: 6.5mm or less Applicable electric wire: 1.25mm2 or more Rubber grommet Power supply cable entry 12-3 Electric circuit For details of the electric circuit, refer to the label on the back of the front panel of this product (see page 1-1). 12-1 Safety instructions 121 IDU Series IDX-OM-W022 Air Dryer 13 Specification
(Ex.) 1. 2. 3. 4. 12-2 IDU22E/37E-23-V IDU55E/75E-23-V IDF-S0198 IDF-S0302 1.6MPa AC230V10% (50Hz) ON 0.5sec 2.0sec OFF 30 IDU Series 121 IDX-OM-W029 12 V 12-3 1) 2) 3) 4) ON OFF 4 6 2 3 2 1 8 4 10 0.5 5 ON:SEC OFF:MIN 0.5 12-4 V 6-4 6-3 T 11-6 11-3 IDU Series 122 IDX-OM-W029 13 13 13-1 / IDU Series 13-1 13-1 B2022 9 Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku
IDFA Series 12-1 121 IDX-OM-W032 12 V 12-2 Drain tube (O.D. 10m) (10) IDFA22E,37E,55E,75E-23-V IDF-S0198 1.6MPa AC230V10% (50Hz) ON 0.5sec OFF 30sec IDFA Series 12-2 122 IDX-OM-W032 12 V 12-3 1) 2) 3) 4) ON OFF 4 6 2 3 2 1 8 4 0.5 0.5 5 ON:SEC OFF:MIN 12-4 R 6-4 6-3 T 11-6 11-3 IDFA Series 12-3 123 IDX-OM-W032 13 13 13-1 / IDFA Series 13-1 13-1 D:2021/11 4-14-1
(2) 17. 18. 19. 20. () IDH Series 22 2.2 IDX-OM-W038 2. 2.2.2 6.2 IDF-AB500 1 2 600mm 600mm 600mm 600mm 600mm 600mm 600mm 600mm 1 2 IDH Series 23 2.2 IDX-OM-W038 2. 2.2.3 4040 3 2 121 2.2.4 10mm ( IDH Series 24 2.2 IDX-OM-W038 2. 2.2.5 ,(6-1 ) 1 2 3(0.61Nm) 4 5 (17) (17) 3 7 6 5 1 2 4 PE M3 6.5mm (N.O) 2 1.25mm (N.C) IDH Series 25 2.2 IDX-OM-W038 2. 2.3
Caution UNITED KINGDOM (44) 0845 121 5122 La puissance de sortie mise par lappareil de sans fil est infrieure la limite d'exposition aux frquences radio dInnovation, Sciences et Dveloppement conomique Canada. Utilisez lappareil de sans fil de faon minimiser les contacts humains lors du fonctionnement normal.
The specification of the terminating resistor is 121 1%, 1/4 W. Fieldbus device Operation Manual Summary of Product Parts Setting Turn off the power supply while setting the DIP switches. Open the cover and set the DIP switches with a small flat blade screwdriver.
The resistor requirements are: 121 1% metal film 1/4 W Terminating resistors should not be installed at the end of a drop line, only at the two ends of trunk line. Side U Side D Connect with DeviceNet communication line. Communication connector 1 (SI unit side) Power supply connector Supplies power to the solenoid valve, the Output block, SI unit and the Input block. 2 Output No.
Station number is set to 0, or to 121 or over. Network number is not set Master request IO size is lager than the actual slave IO size. *1 Red ON *1. The Masters red ERR LED will come on if the Master request IO size is smaller than the actual slave IO size.
Multi channel controller, Low power consumption: 55mA or less, NPN or PNP open collector available, Simplified application, Space saving, MULTI-CHANNEL SENSOR MONITOR, PRESSURE SWITCH, PSE100-560, F39, 121 lb
Multi channel controller, Low power consumption: 55mA or less, NPN or PNP open collector available, Simplified application, Space saving, MULTI-CHANNEL SENSOR MONITOR, PRESSURE SWITCH, PSE100-560, F39, 121 lb
MXS MXQ +1 0 mm Stroke length tolerance Extension end 5 mm/Retraction end 5 mm Stroke adjustment range MXF MXW IN MXJ OUT Theoretical Output (N) MXP Operating pressure (MPa) Bore size (mm) Rod size (mm) Piston area (mm2) Operating direction 0.7 0.6 0.5 0.4 0.3 0.2 MXY OUT 50 35 30 25 20 15 10 8 4 IN 38 27 23 19 11 15 8 MTS 79 68 57 34 45 23 OUT 113 12 6 60 51 43 26 34 17 IN 85 OUT 201 141 121
x 1 thread depth 10 (Mounting thread) 4 x M6 x 1 thread depth 12 (Mounting thread) Bottom hole 5.1 through (Mounting hole) 30 26H9 depth 1.5 + 0.052 0 2 x M6 x 1 thread depth 12 (Mounting thread) MHK 0 0.1 10 Open 41 + 1.2 0 MHS 5 17.5 MHC 81.6 40 84 56 36 MHT 0 0.2 20 0.02 MHY Closed 19 38 MHW 4H9 depth 4 + 0.030 0 33.6 0.05 22 53.5 88.5 25 -X Auto Switch Mounting Groove Dimensions 121
RHC W Z tb T TT ta S Q QW RW PW Model PB REAL15 REAL20 REAL25 REAL32 REAL40 112 0.5 1.0 92 22.5 15 77 12.5 30 70 95 90 RZQ 117 130 16.5 25.5 88 105 40 28 120 90 130 0.5 1.0 127 25.5 22 88 16.5 50 100 130 105 157 149 1.0 18.5 28.5 0.5 102 121 60 33 160 120 D194 1.0 1.0 187 35.5 35 138 20.5 84 140 190 159 -X Individual -X 975 Series REAL Auto Switch Proper Mounting Position (Detection at
only Each 0 to 5 mm on both ends MXP12 MXW Reed auto switch (2-wire, 3-wire) Solid state auto switch (2-wire, 3-wire) 2-color indication solid state auto switch (2-wire, 3-wire) Auto switch MXJ +1 0 mm Stroke length tolerance MXP Theoretical Output (N) MXY MXP16 Operating pressure (MPa) Bore size (mm) 6 8 10 12 16 Piston area (mm2) 0.2 6 10 16 23 40 MTS 0.7 20 35 55 79 141 0.6 17 30 47 68 121
drilled hole and pin hole additionally -XC79 -XB13 Low speed cylinder (5 to 50 mm/s) Theoretical Output -XC3 Special port location (N) -XC19 Intermediate stroke (Spacer type) Piston area (mm2) Operating pressure (MPa) Rod size (mm) Bore size (mm) Operating direction -XC22 Fluororubber seal 0.3 0.5 0.7 19 14 OUT 8 28 3 6 14 10 IN 6 21 55 39 OUT 23 78 4 10 46 33 IN 19 66 141 101 OUT 60 201 6 16 121
14 11 7 M18 x 1.5 M10 x 1.5 depth 16 Up to 300 38 27 20 32 2 35 32 18 71 20 89 20 13 10 M22 x 1.5 M10 x 1.5 depth 22 Up to 300 50 32 25 37 3 40 40 22 71 20 110 20 16 10 M26 x 1.5 M12 x 1.75 depth 22 Up to 300 60 41 30 37 3 40 50 26 (mm) Bore size (mm) Stroke range (mm) 20 25 32 40 50 63 80 100 NA P S TA TB ZZ 11 11 77 1/8 24 114 Up to 200 11 11 77 1/8 29 119 Up to 300 11 11 79 1/8 35.5 121
Station 20 372 359 353 340 3 83 70 81 68 6 134 121 129 116 8 168 155 161 148 10 202 189 193 180 Station 2 66 53 65 52 4 100 87 97 84 5 117 104 113 100 7 151 138 145 132 9 185 172 177 164 11 219 206 209 196 12 236 223 225 212 13 253 240 241 228 14 270 257 257 244 15 287 274 273 260 16 304 291 289 276 17 321 308 305 292 18 338 325 321 308 19 355 342 337 324 Station n L1 L2 L1 L2 A, B port size