Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.
(mm) 4 4 6 6 8 10 12 16 3.18 4.76 6.35 9.53 12.7 Tubing I.D.
Operating pressure Do not use the product beyond the operating pressure range. Do not use in locations where peak pressure exceeds the operating pressure due to water hammer, surge pressure, etc. FGC Bag filter FGF FGF Fluid release valve Tank FGH 2. Operating temperature Do not use the product beyond the operating temperature range.
Symbol Standard Nil Optional Refer to XLA/XLC-16-2 16 Table 3 XLA/XLC-25-2 25 XLA/XLC-40-2 40 XLA/XLC-50-2 50 XLA/XLC-63-2 63 XLA/XLC-80-2 80 Note 1) Bellows assembly contains the valve seal 1.
T-slots l Model Bolt Max. tightening torque Nm Max. screw-in depth (l mm) LXP M5 x 0.8 7.4 8.5 Use bolts at least 0.5mm shorter than the maximum screw-in depth, so they do not touch the body.
The pressure sensors do not have an explosion proof rating. Never use pressure sensors in the presence of flammable or explosive gases.
Do not use the product in the presence of a magnetic field. Malfunction can result. Do not let foreign matter, such as wire debris, get inside the product. Otherwise it can cause damage or malfunction. Do not use the product in an environment that is exposed to temperature cycle.
Values outside the specification range will be recognized as large values and cause Er1, so please do not use them. Relationship between the set pressure (16-Bit) and output pressure Set pressure 0 0x02BC Output pressure 0kPa 700kPa (Example) When the set pressure value is 0x02BC, the output pressure is adjusted to 700kPa.
Do not grip the piping port on the back side or the handles of the panel. 3. Do not pass over bumps, etc., with the casters.
Do not ground to water pipe, gas tube or lightening rod line. 7. Do not connect too many wires to the same outlet, which could results in heat generation and fire. 8. Do not retrofit the wiring of the dryer and the power supply line. 9.
Do not use in potentially explosive environments. It must not be used in an environment with explosive gases, as there is a possibility of explosion. 5. Do not mount the product in locations where it is exposed to radiant heat or other excessive heat. It may lead to damage or malfunction of the board or element. 6. Do not store in a strong magnetic field atmosphere.
Do not use in potentially explosive environments. It must not be used in an environment with explosive gases, as there is a possibility of explosion. 5. Do not mount the product in locations where it is exposed to radiant heat or other excessive heat. It may lead to damage or malfunction of the board or element. 6. Do not store in a strong magnetic field atmosphere.
Do not use with fluids other than compressed air. Cleaning equipment is designed exclusively for use with compressed air. Contact SMC in advance if a fluid other than compressed air is to be used. 2. Do not use compressed air which contains chemicals, organic solvents or corrosive gases.
Do not insert metal wires or other foreign objects into the pressure measurement port.
Motor side 16 pulse End side 1 A Parameter no.
1 Q=226S P(P2+0.1013) Sonic flow : P1+0.1013 1.89(P2+0.1013) Do not use in an explosive environment. 2 Q=113S(P1+0.1013) Q : Flow rate [ /min(ANR)] S : Effective area (mm2) P : Differential pressure (P1-P2) [MPa] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] Do not use in locations subject to heavy vibration and/or shock.
1 8 1 4 3 16 3 16 5 32 1 4 3.5 16.5 3 16 1 4 5 16 4.6 17 1 4 3 8 K 3 8 6 18.5 5 16 1 2 Applicable tubing M 7 21 1 2 3 8 Note) D: Max. diameter H KK D MS Cross: KQ2TW Applicable tubing O.D.
32 3 16 1 4 5 16 3 8 9 16 -18 9 16 -18 3 4 7 8 1-12 1-12 -14 -16 1 2 28.6 22 28.6 9.6 26 Plug: KQ2P, KQP Fitting size d (inch) Part No.
Maximum stations are 16.