Tightening torque: AW10 AW20(K) AW30(K) AW40(K) AW60(K) 21 3 to 4 Nm 12 7 to 9 Nm 14 12 to 14 Nm 7. Pressure Gauge Adapter, Plug Assembly Process Procedure Tools Check item Applicable model Actuators Modular F.R.L. Pressure Control Equipment Disassembly Hexagon wrench key Nominal: AW20(K) AW30(K) AW40(K) AW60(K) 1) Remove the plug.
Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water or steam, or where there is direct contact with same. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5.
Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.
Tightening torque: AW10 AW20(K) AW30(K) AW40(K) AW60(K) 21 3 to 4 Nm 12 7 to 9 Nm 14 12 to 14 Nm 7. Pressure Gauge Adapter, Plug Assembly Process Procedure Tools Check item Applicable model Actuators Modular F.R.L. Pressure Control Equipment Disassembly Hexagon wrench key Nominal: AW20(K) AW30(K) AW40(K) AW60(K) 1) Remove the plug.
(mm) Model N L1 L2 Port B Min. bore Weight (g) L3 L4 L5 L6 P Q1 Q2 MA MB FA FB KRM11-06-10-10 KRM11-06-10-6 76 10 6 6 10 29 47 19.5 31.5 21.5 31 13 13.5 17 21 7.5 10 102 6 85 10 116 41 39 55 73 KRM11-08-12-10 KRM11-08-12-6 8 12 11.5 22.5 35.5 24 34.5 15.5 14.7 18.5 22 9 57 86 Dimensions: KRM12 2-connection thread 2-4.5 mounting hole N-applicable tubing O.D.
Drain Tube Caution Compressed Compressed air outlet air inlet A tube with an outside diameter of 0.47 in (12 mm) is attached as a drain tube. Use this tube to discharge condensate to a drain tank, etc. Do not use the drain tube in an upward direction. Do not bend or crush the drain tube.
Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.
Relay, PLC 24 V Yes Grommet 3-wire (NPN) IC circuit Diagnostic indication (2-color) 5 V, 12 V 3-wire (PNP) 12 V 2-wire A96V A96 IC circuit 5 V 3-wire (NPN equiv.)
Refer to Best Pneumatics vol.8 (CY1 series model selection method) for details. 12-REA40 12-REA40 6 2.1 12-REA50 12-REA50 8 3.4 12-REA63 12-REA63 8 3.4 3. Throttle type speed controllers are recommended for speed adjustment, as shown in the table below. Recommended speed controller Model 5. Do not scratch or gouge the external surface of the cylinder.
Transporting using casters 1) This product is heavy and should be moved by at least two persons. 2) Do not grip the piping port on the right side or the handles of the panel. 3) When transporting using a forklift, be sure not to let it hit the casters or adjusters, and drive the fork all the way through until it comes out the other side. 4) Do not get across steps with casters. 2.
through until it comes out the other side. 4) Do not get across steps with casters.
Caution SMC Pressure Switch and Pressure Sensor do not have explosion-proof construction; do not use flammable gases or liquids. Also, do not use toxic gases or liquids. 888
Hold/Release success: default output DO[101] Hold/Release failure: default output DO[102] * Digital output port can be selected within DO[101] to DO[112] * you select the same digital output port for different status signals, a warning message will be displayed. 2. Test run The manual operation of the magnet gripper unit can be checked.
Do not use non-defined or unavailable addresses or flags. Otherwise, the Card Motor may make an unexpected movement, leading to damage.
Do not use a cable longer than 100 m. For long wire lengths, we recommend a ferrite core should be attached to both ends of the cable, to reduce noise. (2) Do not use a load which generates a surge voltage.
Do not torque it more than required in case to operate a lock type manual.
M5 11.5 1/8 34 (8) Do not use this product in such a way that Body A rotates at any time. Also, do not use it in such a way that moment loads act on it. Body A or the joint may be damaged.