Voltage: 5 (24 VDC), Electrical Entry: DL (DIN Connector with light), Port Size: 04 (1/2), CE Compliant Marking: Q (CE Marking)
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: Q (Stainless Steel Body & Shading Coil, PTFE (FPM) Seal, Class H Coil), Port Size: 04 [1/2 (10,15A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: G (Grommet)
Valve; Stop Valve: None), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow
Valve; Stop Valve: None), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow
Valve: None; Stop Valve: None, Return Port Size: 04 (1/2), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °C)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
: °C, Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Barb one-touch Reducer 3.2, 4 Port size 3 5 32 04 M3 x 0.5 M5 x 0.8 3.2 4 15-6-28 5 Miniature Fittings Series M Barb fitting: M-3AU-2, M-5AU-2 Applicable tubing O.D. x I.D.
Description Material Note IR Aluminum die-casted Body Bonnet Chamber Valve guide Platinum silver painted Platinum silver painted Platinum silver painted Platinum silver painted In the case of AR825/835/925/935, the material is aluminum alloy. q w e r 1. Release the lock to adjust the pressure. After the adjustment, engage the lock.
Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 6 8 10 12 Inch sizes 03 05 07 11 13 1/8 3/16 1/4 3/8 1/2 Different diameter tubing order example Basic size With reducer Note) Applicable fitting: LQ2 Different diameter tubing (with plug-in reducer) can be selected within the same body class. (Example) Body class 3 A side: 10 x 8 B side: 8 x 6 Order as shown below.
.:..aiu.lu:.it:rit spqtrcatrons iet pressure max. 0.1MPa 1 a o iet Dressure max. 0.5MPa o a o iet oressure max. 0.9MPa a o )onnection Rc(Pfl 1/4 02 o o o E EE .ti'6 u, at CL ]onnection Rc(PT) 3/8 03 o o )onnection Rc(PT) 12 04 o Bracket B o o Bracket o o @ L-bracket Connection NPTl/4 N02 a o Connection NPT3/8 N03 a o o tr 6 . 9 o u t = ^ O v o EL o Connection NPTl/2 N04 o Connection G(PD
single Solenoid 2 position / double solenoid 3 position, closed center / double solenoid 3 position, exhaust center / double solenoid 3 position, pressure center / double solenoid t Special order Body optlon 0 _lndividual exhaust for the pilot x and fiain valve 3 _Common exhaust for main valve and pilot valve t Special o.der Vonage 1r-100vAc 5qeHz 2*-200VAC "q.Hz 3-1.1OVAC'eoHz 4-22OVAC q-Hz
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 04 (1/2), Thread: N (NPT), Passage: A (Normally Closed), Option: E (Continuous Duty), CE Compliant: Q (CE Compliant)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Option 1: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket)
Stations: 3 Stations (Note: 1 Station is Required for Serial Unit Mounting), Port Size: 04 (Rc1/2), Electrical Entry Direction: U (U Side Mounting), Kit Type: Q (DeviceNetâ„¢, 16 Output Points), Option 1: SD (Built-in Silencer, Direct Exhaust from D Side)
Stations: 3 Stations (Note: 1 Station is Required for Serial Unit Mounting), Port Size: 04 (Rc1/2), Electrical Entry Direction: U (U Side Mounting), Kit Type: Q (DeviceNetâ„¢, 16 Output Points), Option 1: CD1 (Exhaust Cleaner for Rc1: D Side Exhaust), Option 2: W (Dust Poof IP65 Rated)
Stations: 8 Stations (Note: 1 Station is Required for Serial Unit Mounting), Port Size: 04 (Rc1/2), Electrical Entry Direction: U (U Side Mounting), Kit Type: Q (DeviceNetâ„¢, 16 Output Points), Option 1: SD (Built-in Silencer, Direct Exhaust from D Side)