Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, FX, AS 1/2INCH (MISC./OTHER), .33735 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CNTL METAL BODY W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, FX, AS 1/2INCH (MISC./OTHER), .30646 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, PILOT CHECK VALVE: METAL BODY TYPE, FLOW CONTROL, 60 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, FX, AS 1/2INCH (MISC./OTHER), .36861 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, SPEED CONTROLLER, FLOW CONTROL, SVD, 150.00000 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, FX, AS***F 1/2INCH(MISC./OTHER), .33660 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, FX, AS***F 1/2INCH(MISC./OTHER), .32340 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL, SPL, FLOW CONTROL, SVD, 20.00000 lb
① When there is no piping rotation stopper, the part numbers are as follows: IRV10-01/02□-X3 and IRV20-02/03/04□-X3.
② When there is a piping rotation stopper, the part numbers are as follows: IRV10-01/02□-X28 and IRV20-02/03/04□-X28.
The IRV10 series catalog can be found here.
① When there is no piping rotation stopper, the part numbers are as follows: IRV10-01/02□-X3 and IRV20-02/03/04□-X3.
② When there is a piping rotation stopper, the part numbers are as follows: IRV10-01/02□-X28 and IRV20-02/03/04□-X28.
The IRV10 series catalog can be found here.
elbow style; Meter-in or meter-out control; Port sizes: M5, 01, 02, 03, 04; Tube O.D.: 04, 06, 08, 10, 12
Port size Symbol 01 02 02 03 03 04 Body class Port size 1/8 1/4 1/4 3/8 3/8 1/2 Pilot port thread type 2 Symbol Nil N Thread type Rc NPT 3 4 Integral fitting type/Variations Model LVH20 LVH30 LVH40 Orifice diameter 4 8 10 Tubing O.D. Metric 3, 4, 6 6, 8, 10 10, 12 Valve type Inch 1/8, 3/16, 1/4 1/4, 3/8 3/8, 1/2 Symbol Type Basic type N.C.
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
10 10 12 12 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" -X214 Restrictor (Without check valve) With One-touch ttings Example) AS2002FS-04-X214 With indicator 10Clean Series 1 For selecting applicable tubing O.D., refer to the Model shown above. 2 Use 1/8" tubing.
Class Instance Attribute Description Value 01h (01) 01h (01) MAC ID (Node address) 0 to 63 03h 0: 125 kbps 1: 250 kbps 2: 500 kbps (DeviceNetTM) 01h (01) 02h (02) Baud_rate (Communication speed) : The address and communication speed set in SW mode will be kept even after the DeviceNetTM communication power supply to the SI unit is turned off.
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
Please contact us for the latest version.sales@ocaire.com, MANIFOLD, BASE MT, VALVE, SS5YJ7 MANIFOLD SYJ7000 5/PORT, DJ, SS5YJ7 BODY PORT 1/8 PT, 1.85899 lb
Please contact us for the latest version.sales@ocaire.com, MANIFOLD, BASE MT, VALVE, SS5YJ7 MANIFOLD SYJ7000 5/PORT, DJ, SS5YJ7 BODY PORT 1/8 PT, .00000 lb
Please contact us for the latest version.sales@ocaire.com, MFLD, BASE MT, VALVE, SS5YJ7 MANIFOLD SYJ7000 5/PORT, DJ, SS5YJ7 BODY PORT 1/8 PT, .75587 lb
Please contact us for the latest version.sales@ocaire.com, MFLD ASSY, VALVE, SS5YJ7 MANIFOLD SYJ7000 5/PORT, DJ, SS5YJ7 BODY PORT 1/8 PT, 1.98416 lb