Finally, find the pilot air pressure and pilot air consumption based on selection from the flow rate characteristic graphs. 0 1 10 100 1000 Viscosity (mPas) Caution Viscosities up to 1000mPas can be used. 2 Series PA3000/5000 Operating Principle/Automatically Operated Type Air exhaust port Switching valve Air supply port Drive unit Control unit Pilot valve A Pilot valve B Discharge port (

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Residual voltage 1 V or less (with load current of 80 mA) Response time 2.5 ms (Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms) ZSP Short circuit protection With short circuit protection 0.5%F.S.

P N E U T / | A T I C T E C H N O L O G Y Average plston speed ln mm/s 150 200 250 300 400 0.15 0.2 0.25 0.3 0.4 0.36 0.46 0.6 0.72 1 1000 1 2.4 4 6.7 1 1 1 7 27 500 0.5 750 0.75 1.8 3 5 8.5 12.8 20.3 50 100 0.1 0.1 0.12 0.23 o.2 0.4 0.35 0.67 0.55 1.r 0.85 't .7 1.4 2.7 2.'l 4.2 3.4 6.8 5.4 10.8 a.4 16.8 10.6 21.'

Note 2) Do not use MGPL(ball bushing bearing) as a stopper. 1 5 10 20 30 40 50 Transportation speed: u (m/min) Bore Size 32 to 100/MGPM32 to 100 (Slide Bearing) MGPM32 to 100 (Slide Bearing) 2000 m u m u l @ 50mm l @ 50mm 100 1000 80 Transported object weight: m (kg) 63 500 400 50 300 40 200 *When requiring a bracket with a longer l dimension select a bore size large enough to accommodate

Data 0.1 YES Caution on Selection Operating pressure (MPa) 1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 10 100 1000 0.05 0.1 0.2 0.4 0.5 1 2 3 0.05 0.5 0.01 In order for the shock absorbers to operate accurately for long hours, it is necessary to select a model that is well-suited to your operating conditions.

6432 5718 5003 4288 3574 2859 2144 1429 12270 OUT 12270 11040 9820 8590 7360 6150 4910 3680 2450 32 125 11250 IN 11250 10130 9000 7880 6750 5630 4500 3380 2250 20100 OUT 20110 18100 16080 14070 12060 10050 8040 6030 4020 40 160 18850 IN 18850 16960 15080 13190 11310 9420 7540 5650 3770 Note) Theoretical force(N) = Pressure (MPa) X Piston area (mm2) Allowable Kinetic Energy ( ) 3000 2000 1000

Lead wire length 2000 mm Cover Concave Pin Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lever DC indicator Socket Part no.

Order Connector Assembly for L/M Plug Connector Construction Series SX Positive common specifications 2 position single JIS Symbol 2 position single For single solenoid: SX100 40 4S For double solenoid, 3 position: SX100 40 4D Negative common specifications For single solenoid: SX100 41 4S For double solenoid, 3 position: SX100 41 4D Lead wire length Nil 300 mm 6 600 mm 10 15 20 25 30 50 1000

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

Order Connector Assembly for L/M Plug Connector Construction Series SX Positive common specifications 2 position single JIS Symbol 2 position single For single solenoid: SX100 40 4S For double solenoid, 3 position: SX100 40 4D Negative common specifications For single solenoid: SX100 41 4S For double solenoid, 3 position: SX100 41 4D Lead wire length Nil 300 mm 6 600 mm 10 15 20 25 30 50 1000

Note) White (Gray) [Gray]: B side solenoid () White: B side solenoid (+) Example) Lead wire length 1000 mm Example) Lead wire length 1000 mm VQ1170-5LO-C6 AXT661-14A-10 3 pcs. 3 pcs. 3 pcs. 3 pcs. VQ1170N-5LO-C6 AXT661-14AN-10 Connector Assembly Part No. (For DC) Connector Assembly Part No. (For DC) Double solenoid part no.

ISG ZSM OUT OUT 1 1 OUT Input an arbitrary three-digit value. 1 OUT OUT 2 2 OUT 2 (Only the indicated value changes without changing precision.) 1/1000 1/100 The set-value can be confirmed even when the key is locked. Power-saving mode Turning off the display can save power consumption.

Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) D16 100, 200, 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1400, 1600, 1800, 2000 3000 -X 25, 40 5000 Strokes are manufacturable in 1 mm increments, up to the maximum stroke. When exceeding a 2000 mm stroke, specify -XB11 at the end of the model number.

20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Non-lubricated exterior (without dust seal) 25 1500 Outside of cylinder tube with hard chrome plated 32 Non-lubricated exterior (with dust seal) 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 1500 40 Switch rails on both sides (with 2 pcs.)

E/P Pressure Regulator Manufacturing Pneumatics Worldwide Electro-Pneumatic Regulator Compliant Electronic Vacuum Regulator How to Order ITV 2030 SEN DUQ00833 2 X26 Port Size 1 2 3 4 1/8 (1000) 1/4 (1000, 2000) * 3/8 (2000, 3000) * 1/2 (3000) Body Size 1010 1030 1050 2010 2030 2050 2090 3010 3030 3050 * Note: 2090 available with 1/4 port only.

sliding part Bore size (mm) 300 15 12 CY3B Cylinder stroke (mm) Type Bore size Port thread type Symbol 6 10, 15 M3 x 0.5 M5 x 0.8 Rc NPT G Nil 20, 25, 32, 40 50, 63 TN TF Model Maximum manufacturable stroke Cushion Bore size (mm) Standard stroke (mm) Port size Lubrication Model Rubber Air M3 x 0.5 12-CY3B6 6 300 50, 100, 150, 200 M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000

(mm) Piston speed (mm/s) Lock type 100 300 500 1000 0.3 0.6 1.0 2.0 Spring locking Condition: Lateral, Supply pressure P = 73 psi Load weight Upper limit of allowed value Solenoid valve for locking mounted on the unlocking port Maximum value of stopping position dispersion from 100 measurements 4

Outside of cylinder tube with hard chrome plated 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 Auto switch rails on both side faces (with 2 pcs.) 1500 Made to Order Specifications Click here for details 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 40 1500 Symbol Specifications -XB9 -XB13 -XB22 Low speed cylinder (15 to 50 mm/s) Note) Intermediate stroke

Note 2) The piston speed is 100 to 1000 mm/s for centralized piping. Note 3) Use at a speed within the absorption capacity range. Refer to page 1211.