, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: °C), Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: °C, Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Metering Valve with Silencer Series ASN2 Superior sound reducing performance Over 20 dB at max. flow rate Cylinder speed easily set Shape of needle is the same as that of speed controller Retainer prevents accidental loss of needle Model Model Port size Effective area (mm 2) Weight (g) ASN2-M5 ASN2-U10/32 ASN2-01 ASN2-02 ASN2-03 ASN2-04 M5 x 0.8 10-32 UNF 1.8 1.8 3.6 6.5 16.6 24.5 5 5 17
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
°C), Bracket: R (w/Bracket), Calibration Certificate: A (w/Calibration Certificate), Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
), Calibration Certificate: A (w/Calibration Certificate), Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: °C), Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)