5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 3513.0/14.5 (at 20C)??1.00.28/0.31 (at 42/53 l/min, total lifting height 25/25 m)42/5360Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????

ARated power consumption Note 11) (50/60 Hz) kWRemote operation signal inputOperation signal outputAlarm stop signal outputAlarmHRGC002Air-cooled refrigerationR407C (HFC)Refrigerator ON/OFF control or Proportional valve PID controlTemperature: 5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycolFor externally sealed circuit5 to 351.9/2.3 (at 20C

5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 3513.0/14.5 (at 20C)??1.00.28/0.31 (at 42/53 l/min, total lifting height 25/25 m)42/5360Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????

40mm, Double acting and Single acting available, Auto switch capable, Improved rigidity of guide rail, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, HT, 20MM MHZ2, .54066 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-20C

Note 2) The above data is based on a room temperature of 20C. Note that you may obtain different figures, depending on temperature conditions. Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance. In addition, using fluids other than those specified in the catalog are not covered by the products warranty.

Rod Boot Material 125 140 160 180 200 250 Max. ambient temperature Symbol Material Bore size (mm) J 20C Foot type Note 1) Nylon tarpaulin CS1-L12 CS1-L14 CS1-L16 CS1-L18 CS1-L20 CS1-L25 110C K Rod flange type Note 2) Heat resistant tarpaulin CS1-FL12 CS1-FL14 CS1-FL16 CS1-FL18 CS1-FL20 CS1-FL25 Head flange type Maximum ambient temperature for the rod boot itself.

capacity (cm3) 55 135 7 25 135 135 135 Recommended lubricant Class 1 turbine oil (ISO VG32) 5 to 60C (With no freezing) Ambient and fluid temperature Bowl material Polycarbonate Bowl guard Option Standard Weight (kg) 0.47 0.24 1.13 0.07 0.20 0.52 1.06 Note 1) The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C

Filtration grade E5 General Purpose E1 Prefiltration / Coalescing EA High Efficiency Coalescing Ac C Description Particle removal, m 5 1 0.01 Max. particle size class 4) 3 2 1 Max. oil content class 4) 4 5 2 0.1 1 0.01 Max. oil carryover 68F (20C), ppm Recommended temperature, F (C) Max. temperature, F (C) Max. working pressure, psig Pressure loss clean & dry, psid Pressure loss oil saturated

ASD330F CM2 VZ500 TU0604 1 m AN11001 25 Cylinder size 32 Values at 0.5 MPa and 20C. Cylinder extension speed: 100 mm/s Meter-out needle fully open 100 mm/s Return speed Solenoid valve (Reference) Recommended circuit for high return speed When low extension speed and high return speed are desired, the following circuit using 3-port is recommended.

capacity (cm3) 55 135 7 25 135 135 Recommended lubricant Class 1 turbine oil (ISO VG32) 5 to 60C (With no freezing) Ambient and fluid temperature Bowl material Polycarbonate Bowl guard Option Standard Weight (kg) 0.47 0.24 1.13 0.07 0.20 0.52 1.06 Note 1) The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C

Wiring & Light / Surge Voltage Suppressor How to calculate Flow (At an air temperature 20C) AC AND 100 VDC AC AND 100 VDC WITH LIGHT WITH LIGHT TERMINAL no.1 (+) TERMINAL no.1 (+) Subsonic flow: P1+0.1013<1.89(P2+0.1013) SINGLE SINGLE Q=226S P(P2+0.1013) Sonic flow: P1+0.1013>1.89(P2+0.1013) ZNR ZNR Q=113S(P1+0.1013) Q: Flow rate under standard conditions [l/min(ANR)] S: Effective area (mm2

/min (ANR)] Note) 1/4: 30 3/8: 40 15 Oil capacity (cm3) Recommended lubricant Bowl material Bowl guard Weight (kg) 25 55 135 Class 1 turbine oil (ISO VG32) Polycarbonate 0.43 Standard (Polycarbonate) Semi-standard (Steel) 0.10 0.20 0.38 Note) The flow rate is 5 drops or greater/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C

Standard condition (ANR) and normal condition (NOR) are defined as follows: Standard condition (ANR): 101.3kPa, 20C, 65%RH. Normal condition (NOR): 101.3kPa, 0C Press the or button in f function selection mode to display [F 4]. Press the button. Select reference condition [rEF] and the set value are displayed in turn.

Operating temp. range Operating humidity range [%RH] Motor size Motor type Motor type S2, S3: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7: Absolute 18-bit encoder (Resolution: 262144 p/rev) Encoder Type Note 7) 29.4 57.3 6.3 109 35.3 Non-magnetizing operation type 69.2 7.9 specifications Holding force [lbf] 132.3 44.3 86.6 7.9 165.5 Power consumption [W] at 68F (20C

Rod Boot Material Max. ambient temperature Symbol Rod boot material J 20C Nylon tarpaulin 110C K Heat resistant tarpaulin Maximum ambient temperature for the rod boot itself.

(Coil temperature: 68F (20C), at rated voltage) 16 Series VF3000/5000 Flow-rate Characteristics/Weight Flow-rate characteristics Note 1) Weight (g) Note 2) 1 l 4/2 (P l A/B) 4/2 l 5/3 (A/B l EA/EB) Type of actuation Valve model Port size C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet DIN terminal Single 2.8 0.14 0.64 2.5 0.18 0.57 344 (192) 380 (228) 2-position Double 2.8 0.14 0.64 2.5

0.098 (2.5mm) 0.51 (13mm) TIA05 3/16 0.137 0.79 TIA07 1/4 0.18 1.18 T0806 5/16 (8mm) 0.236 (6mm) 1.89 (48mm) TIA11 3/8 0.275 2.36 TIA13 1/2 0.378 2.95 TIA01 1/8 0.086 0.59 Model O.D. inch I.D. inch Min. bending radius inch Length 100ft (33m) 20m 100m 500ft (153m) 1000ft (305m) Roll Reel Specifications Operating fluid Max. operating pressure Burst pressure Air, Water 218psi (1.5MPa) at 68F (20C

Voltage for 20C-114 POTTED (Type P)Class F rated at 105IEEE* and 110 C. Continuous & 125 C. IntermittentU.L.** Peter Paul Rating*** 125 Continuous. The unit is water proof. *IEEE*The temperatures listed are the limiting temperature definitions by this organization for insulation material categories. Therefore, a 2C-115 coil should be used with a field Voltage of 130 volts 60 cycles.

(coil temperature 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.