Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Response Time Response time ms (at 0.5 MPa) 7 or less Mass Valve model Number of solenoids 1 pc. (Single) 2 pcs.

10 10 54 32 26 11 22 20 44 16 11 15 6 27 71.5 60 42 22 21 150.5 8 M8 x 1.25 25 to 800 25 to 650 50 35 12 13 10 59 40 27 11 27 21 52 20 10 17 9 32 80.5 70 46 24 28.5 162.5 11 M8 x 1.25 25 to 800 25 to 650 60 35 15 18 10 67 40 26 27 23 64 20 13 17 9 32 98.5 85 48.5 24 28.5 174 11 M10 x 1.25 13.5 25 to 750 25 to 600 70 40 17 23 14 72 52 30 32 23 78 25 15 21 11 37 117.5 102 55 26.5 36 189 13

VCB22 Cv = 0.16 10 Flow rate Q l /min How to find the flow rate for water 5.0 Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min VCB 3 Cv = 0.35 3 4 Formula based on effective area (Smm) 1.0 Q = 0.8 S 10.2 P l/min VCB23 Cv = 0.33 VCB25 Cv = 0.65 Q: Flow rate (l/min) P:Pressure differential (P P) P: Upstream pressure (MPa) P: Downstream pressure (MPa) S: Effective area (mm) Cv

Terminal q DC (+) w N.C e DC () r IN (1 to 5 V) e w q Power supply/Output connection cable (Accessory) Power supply/Output connector (8P) Pin no. 7 Green 8 Yellow 6 Red 5 Gray 4 White 3 Black 2 Blue 1 Brown i u y t r e w q Pin no.

For specifications, refer to page 10-20-66. Normally closed (NC = b contact), solid state switch (D-Y7G/Y7H type) are also available. For details, refer to page 10-20-41. 5 6 6.5 6.5 7 Data 6 7 7.5 7.5 8 9 9 10 10 11 Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.)

Model Option 10-/21-AR20(K)-B 10-/21-AR25(K)-B 10-/21-AR30(K)-B 10-/21-AR40(K)-B 10-/21-AR40(K)-06-B 10-/21-AR50(K)-B 10-/21-AR60(K)-B Bracket assembly Note 1) AR50P-270AS Note 2) AR20P-270AS Note 3) Note 3) AR25P-270AS AR30P-270AS AR40P-270AS Set nut AR20P-260S AR25P-260S AR30P-260S AR40P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Standard Pressure gauge Note 4) 10: G49-4-01, 21: G49-4-01

Standard Strokes Bore size (mm) Standard strokes (mm) 20 32 40 50 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic Fluid Compatibility 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 80 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic fluid Compatibility

Disassembly 1) After loosening the screw q, then if the housing w is pulled in the direction of the screw q, the connector will be removed from the body of equipment (solenoid, etc.). 2) Pull the screw q out of the housing w. 3) On the bottom part of the terminal block e, theres a cut-off part o.

Minimum Stroke for Auto Switch Mounting (mm) 12 16 20 25 32 40 50 63 80 100 Auto switch model No. of auto switches mounted 1 pc. 10 5 D-A9 2 pcs. 15 10 D-A9V D-M9V 1 pc. 5 2 pcs. 10 1 pc. 15 10 5 D-M9 2 pcs. 15 10 1 pc. 15 10 D-M9W 2 pcs. 15 10 1 pc. 10 D-M9WV 2 pcs. 10 D-Z7 D-Z80 1 pc. 10 5 2 pcs. 15 10 D-Y59 D-Y7P 1 pc. 5 10 2 pcs. 15 10 D-Y69 D-Y7PV 1 pc. 5 2 pcs. 5 D-Y7W D-Y7WV 1 pc.

possible (1 l/min) 10 1 to 10 l/min 4 With neon light (220 VAC, Green) 20 10 to 20 l/min Simple flow setting Without removing the cover, you can set with a screwdriver from the outside.

CHKDB CHKGB Double acting, Single rod 40 10 16 CX 50 5, 10, 15, 20, 25, 30 35, 40, 45, 50, 75 100 63 CY 80 100 MQQ M CHKDB CHKGB RHC MK(2) RS Q G RS H A For details, refer to the catalog CAT. E111.

The set value can be copied to up to 10 switches simultaneously.

(FKM) 1.3 x 10-8 Internal 1.3 x 10-10 (FKM) 1.3 x 10-8 DNil A B C Seal material XSA Symbol Nil N1 1.3 x 10-8 1.3 x 10-10 (FKM) 1.3 x 10-8 Seal material FKM EPDM Barrel Perfluoro Compound no. 1349-80 2101-80 1.3 x 10-10 (FKM) XVD Note 1) Values at ambient temperatures, excluding gas permeation.

This control is not for synchronizing the position of the main axis and slave axis. 10 10 Current position Current position Origin 0 0 Origin 10 20 30 40 50 Axis 1 10 20 30 40 50 Axis 1 For 3 Axes JXC92 Series For 4 Axes JXC73/83/93 Series p. 3 p. 4, 5 VParallel I/O/ V Type V Width: Approx. 38% reduction Type V Width: Approx. 18% reduction 78 47 mm shorter 140 30 mm shorter JXC73/83 JXC92

The allowable voltage fluctuation rate is 10% of the rated voltage value for both AC and DC.

VQ1000-FPG-C4M5-D: 6 sets Double check block 757 S0700 Series Construction Body Ported Construction 2(B) (A)4 S0716 2-Position Single r u e w q 3(R2) (R1)5 1 (P) t y i 2-Position Double S0726 2(B) (A)4 r u e w q 3(R2) (R1)5 1 (P) t y i 3-Position Closed Center S0736 r u e w q 2(B) (A)4 (R1)5 1 (P) 3(R2) t y i 4-Position Dual 3-Port Valve S07A6 r u e w q 2(B) 4(A) 5(R1) 3(R2) 1(P) N.C. + N.C

Gauge port 2) (Inlete, Outletr) Porting Configuration Pressure gauge Code r psig/bar unit MPa unit r e 0 6 10 20 40 60 Q No pressure gauge w q w q 600 psig/bar 3) 4.1 MPa 7 MPa 14 MPa 28 MPa 41 MPa 70 MPa qIN wOUT eGauge port (Inlet) rGauge port (Outlet) Connections (Inletq, Outletw) 1000 psig/bar 3) Ports Code 2000 psig/bar 3) Connections 4P V 4PN 4000 psig/bar 3) e 4P 4PN 4 4B NPT 1/4 inch

MY2 H/HT MY3A MY3B MY3M Load Mass Allowable Moment MY1H/m3 MY1H/M3 MY1H/M1 MY1H/M2 q r w e t 30 40 50 50 40 30 40 50 30 40 50 30 20 20 20 20 MY1H40 MY1H32 10 10 10 MY1H40 MY1H40 MY1H32 Load mass kg MY1H32 Moment Nm Moment Nm Moment Nm 5 4 3 MY1H25 MY1H40 10 5 4 3 5 4 3 MY1H32 MY1H25 MY1H25 2 MY1H25 5 4 2 2 1 3 1 1 0.5 0.4 0.3 2 0.5 0.4 0.3 0.5 0.4 0.3 D0.2 1 0.2 0.2 0.1 -X 100 200 300 400