Contents Nickel plated 11 Plug (M-5P) Brass CX2N10 CX2N10-PS 12 Magnet A set of @0, @1, @3 listed above CX2N15 CX2N15-PS 13 Nickel plated Ball fixing screw Chromium steel DCX2N25 CX2N25-PS 14 Spring Stainless steel Seal kit includes @0, @1, @3. Order the seal kit, based on each bore size. (The piston gasket @2 is not replaceable.)
B Q L2 L3 L4 L5 L6 L1 H 1(P) 2(A) C D E F G J K 1(P) R 2(A) 2(A) R 3(R)* VHK-01S-M5 VHK-M5-M5 11 1.2 26 23 11 3.5 41 18 54 51 11 M5 M5 M5 VHK-B1A 44.5 14.5 1 27 22 16.5 26 2.0 2.0 29.1 16.5 29 29.1 61.6 58.2 1 8 11 3.5 41 8.6 1.2 13 18 13 VHK-B1A 44.5 14.5 1 27 22 16.5 26 32.6 16.5 VHK-01S-01S 1 8 1 8 30 57 32.6 65.2 VHK-02S-01S 18 41 71.6 39 32.6 39 78 16.5 3.5 11 9.0 9.7 1.2 39 13 47 62
/14 5/7 13/14 5/5 Rc 1/2 Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass 3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation 10% 30 19 26 60 46 20 14 Refer to page 94.
Lead wire color Dot marking 1 Black None 1 Black None 2 2 Brown None Brown None 3 3 Red None Red None 4 4 Orange None Orange None 5 5 Yellow None Yellow None 6 6 Pink None Pink None 7 7 Blue None Blue None 8 8 Purple White Purple White 9 9 Gray Black Gray Black 10 10 White Black White Black 11 11 White Red White Red 12 12 Yellow Red Yellow Red 13 13 Orange Red Orange Red 14 14 Yellow Black
Individual -X Rod end nut 28.5 851 Series RLQ Dimensions: 50 (Emergency stop) Both ends tapped style: RLQA50 3.2 3.2 16 16 2 x 4 x M6 x 1 Basic style (Through-hole): RLQB50 PC Head side cylinder port PC Rod side cylinder port LOCK Extension locking 69.5 28.5 M10 x 1.5 Effective thread depth 15 13 86 Dust cover (Manual unlocking unit) 20 64 50 19 1.6 2 x Cushion needle 6.6 4 x 13 Depth of
Assembly of a piston and a seal (KSYP-13). Note 2) Bowl O-ring is included for the AW20(K) to AW60(K). Please contact SMC regarding the bowl assembly supply for psi and F unit specifications. Note 3) Bowl assembly for the AW30(K) to AW60(K) models comes with a bowl guard (steel band material).
) Note 13) Note 13) i Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, F Note 8) Pressure can be set higher than the specification pressure in some cases, but use pressure within the specification range.
Spring washer Steel wire 11 Black zinc chromated Retaining plate bolt 12 Black zinc chromated Chromium molybdenum steel Spring washer Steel wire 13 Black zinc chromated Rod seal 25 Cushion ring A Rolled steel Zinc chromated 14 NBR Piston seal 26 Cushion ring B Rolled steel Zinc chromated 15 Air-hydro Seals except @5 and @6 are the same as for the lube-type.
Startup . 10 3.1 Startup procedure. 10 3.2 Procedures for actuator operation . 11 3.3 Setup software (MR Configurator2TM ) . 12 3.3.1 Installation method . 12 3.3.2 Startup setup software (MR Configurator2TM) . 12 3.3.3 System settings . 13 3.3.4 Model selection. 13 3.3.5 Driver ON LINE check . 14 3.3.6 Help function . 14 4. Parameter setting . 15 4.1 Operation modePr.
After settling time, the operation of step data No.20 is 13 completed. 14 :01_EE_22_0_10 :01EEOK Step Data No. 20 target position changed to 10mm. 15 :01_OE_20_1_0 :01OEOK Instruction to hold current position sent. (Preparation for start of Step Data No. 20 operation) 16 :01_OE_20_1_1 :01OEOK Instruction to execute Step Data no.20 sent.
Note 13) When option Y is selected, V for (4) exhaust sealing valve cannot be selected. -10No. ZKJ-OM00201-D 2.
Inspection record . 13-1 13.1 INSPECTION RECORD . 13-1 IDFC60/70/80/90 Series IDX-OM-U010 Chapter 1 Safety Instructions Chapter 1 Safety Instructions 1.1 Before Using Air Dryer.
Inspection record . 13-1 13.1 INSPECTION RECORD . 13-1 IDFB60/70/80/90 Series IDX-OM-V024 Chapter 1 Safety Instructions Chapter 1 Safety Instructions 1.1 Before Using Air Dryer.
) AR24P-370AS-01 Rc / G AR24P-370AS-N01 NPT AR24P-320AS-01 Rc (14) Plug assembly Including part (13)) AR24P-320AS-N01 NPT AR24P-320AS-F01 G The numbers in the table and structural drawings are consistent with the numbers in sections [10.
(Page 13) 0x000C (12) 0 R/W Device Access Locks N For more details, refer to "Device access lock parameter."
No.7 No.8 No.8 No.9 No.10 No.11 No.12 No.13 No.14 -74No.PS-OMV0003CN-G No.
No.7 No.8 No.8 No.9 No.10 No.11 No.12 No.13 No.14 -78No.PS-OMV0008CN-E No.
Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Item Pressure gauge measurement value (PD) Diagnosis OUT2 OUT1 The process data of this product is Big-Endian type. When the transmission method of the upper communication is Little-Endian, the byte order will be changed. Refer to the table below for the Endian type of the major upper communication.
Specifications (2 port solenoid valve) Refer to "Option/Part number" (page 13) or the catalogue of the standard 2 port solenoid valve for the detailed specifications of models other than X276. -17No.PS-OMW0009-C 2 About this product Characteristics graph Supply pressure dependence characteristics The detection distance for turning ON the output depends on the supply pressure.
Symbol Number of arranged elements 4 7 13 19 Number of arranged elements 30 36 55 83 04 07 13 19 30 36 55 83 Symbol Nominal filtration accuracy (m) Note) Nominal filtration accuracy (m) 0.5 1 2 5 10 20 40 Symbol Nominal filtration accuracy (m) 50 70 74 75 100 105 120 X50 001 002 005 010 020 040 050 070 074 075 100 105 120 Symbol Element length Element length L250 L500 (L250 x 2) L750 (L250