Contact P/A. DC(+) Sensor input: DC+ 1 to 5V CH3_OUT1 (Orange) DC() N.C. CH4_OUT1 (Pink) DC(+) Internal data error. Sensor input: DC+ 1 to 5V Load Load Load Load Load DC() DC() (Blue) N.C. Shut off the power supply and turn it back on. Contact P/A if it does not recover. Internal data error.
Table 1 Table 2 Output type ON YES Hysteresis mode For air OFF P-1 P-2 Display Instantaneous flow rate l/min Cumulative flow rate l Large flow rate "P" H H H (fixed hysteresis) = 3 digits CFM x 10-2 ft3 x 10-1 ON CFM = ft3/min Window comparator mode NO OFF P-1 P-2 For water Large flow rate OUT1 Output mode Display Instantaneous flow rate l/min Cumulative flow rate l ON YES OUT2 is the
Set value correction by auto shift function Supply pressure normal Supply pressure drop Supply pressure increase F Reset function P-1 C-5 C-5 (P-3) (Differential) Pressure This function clears and resets the zero value on the display of measured (differential) pressure within 7%F.S. of the factory adjusted value.
Made to order options (see Page 55) Low temperatureresistant (XB6) resistant Modification of rod end auto switch Page P 8 P 1 7 P32 fechnical Data Auto switch guide P 4 6 P 3 8 ?
3(R2) (R1)5 1 (P) 3(R2) e q w e w q VQC1201 VQC1200 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) r r e q w e q w VQC1300 VQC1400 VQC1301 VQC1401 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) VQC1500 VQC1501 r r 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) e q w VQC1A01 VQC1B01 2(B) 4(A) 4(A) 2(B) 1(P)
A A1 E1 L1 NZ 16 16 20 22 28 38 44 34 41 42 56 71 79 25 30 30 40 50 55 20 25 32, 40 50, 63 80 100 20 25 32, 40 50, 63 80 100 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10 Y-G02 Y-G03 Y-G04 Y-G05 Y-G08 Y-G10 34 41 42 56 71 79 25 30 30 40 50 55 IY-G02 16 20 IY-G03 20 22 IY-G04 36 28 IY-G05 44 38 IY-G08 56 44 IY-G10 Knuckle pin and snap ring are included. 64 Knuckle Pin (Common with double clevis pin
(Select wiring bottom entry when the semi-standard Y is chosen simultaneously.) *6 Pressure can be set higher than the specification pressure in some cases, but use pressure within the specification range.
SYJA 1 (P) (EB)3 5(EA) VFA3000 VFA5000 VZA t (A)4 2(B) 3 (EB) 5 (EA) 1 (P) 5 (EA) 3 (EB) 1 (P) VFA VFA r y 1 (P) (EA)5 3(EB) VFRA 2 position double VPA4 Symbol 2 position double SYJA r t q q VFA1000 (B)2 4(A) w w (A) 4 (B) 2 (A) 4 (B) 2 VZA 5(EA) 1 (P) (EB)3 VTA VFA3000 VFA5000 2(B) (A)4 VGA 3 (EB) 5 (EA) 1 (P) 1 (P) 5 (EA) 3 (EB) t r (EA)5 1 (P) 3(EB) VPA VPA3 3 position closed center/exhaust
P Z G Q N Y Y (mm) (mm) Port size Weight (kg) d N P Q Y (mm) Port size Weight (kg) d 25 25 25 28 28 28 28 28 Port size Weight (kg) E 47 47 52 58 58 63 G 9 9 9 9 9 9 9 9 Z 2.8 2.8 2.8 5.3 5.3 5.4 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 1/2 3/4 1 1 1/4 1 1/2 2 22.2 27.7 34.5 43.9 49.1 61.1 77.1
Y (EX245-DX1)(EX245-DY1) Y 2 PCA-1557785 Y (2M12 M12) A A A . 10-2 Y (PCA-1557785) 64 No.EX-OMU0020CN PCA-1557798 Y (2M8 M12) A . 10-3 Y (PCA-1557798) 65 No.EX-OMU0020CN 10.3.
1 e w r e Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com u r u t t y y q q Component Parts Description Material No. Option Standard Stainless steel Body C37 q w e r t y u i o !0 !
Description Solenoid assembly Material Note Epoxy Stainless steel DXT170-AVZ110 t 1(P) (SUP port) 1(P) (EXH port) Epoxy Stainless steel Solenoid assembly DXT170-EVZ120 y u Common with Series VZ 00 3 5 3(R) (EXH port) 3(R) (SUP port) 13 x 11 x 1 NBR O-ring 4-6-6 7 3 Port Solenoid Valve Rubber Seal, Body Ported Series VZ100 Body Ported Grommet (G), (H) VZ10-M5(-F) G H (Mounting hole) V100 SY
2 @5 @4 r @3 e @6 @1 @2 #1 t y $1 u w q E' Section E-E' CYV32 t !9 $0 @1 @2 y @4 @3 u @6 #9 @5 Description Material Note Parts list Description Material Note No. No.
F B With pressure at head side With pressure at rod side *Refer to p.5.3-2 for further information on the auto switch.
Auto shift function (P. 16-3-17) Allows stable switch output even when supply pressure changes.
ZSE ISE P-1 C-5 C-5 (Differential) Pressure (P-3) H-1 (H-2) PSE G Error indication function Z I SE3 ON OFF Switch output 1(2) Description Error code Error name PS OUT1 Switch output response time when auto shift is input. Overcurrent error Load current of switch output exceeds 80 mA.
NX NZ D1 L RR1 RR1 A1 L1 U1 Y-08D 80 37 36 18 71 M22 x 1.5 19 28 18 28 +0.3 +0.1 55 76.5 4 x 25 L Polished round 18 D1 A1 L1 U1 RR1 Y-10D 100 37 40 21 83 M26 x 1.5 21 38 20 30 +0.3 +0.1 61 83 4 x 30 L Polished round 20 RR1 A knuckle pin, split pins and flat washers are included. 2 x d 2 x d Dd9 Dd9 Clevis Pin/Knuckle Pin (mm) Material: Carbon steel Part no.
L1 L2 5 P = 19 14 24.5 (mounting holes) 49.5 11.5 8.5 2 18.5 R P R P 11.5 18 37 11.5 18 37 67.5 59 Max .10 71.5 Pg.7 Manual override (non-locking) 4Rc(PT) 1/8 (ports P, R) 18 25 31 53.5 Approx. 300 (lead wire length) Light (DZ type only) 4Rc(PT) 1/8 (ports P, R) 75.5 83 Manual override (non-locking) nRc(PT) 1/8 (port A) Applicable cord O.D. 4 to 6.5 A A P = 19 20 L: Dimension table n: Stations
VY1A00 1, VY1B00 1 (Pilot valve: VY1D00-00) Working principle The supply (P to A) valve of valve y and the exhaust (A to R) valve close due to the balance between actuating forces F1 and F2.