SMC Corporation of America
Elite Part Number Search
Search Results "IR3010-F02-A"

Rated Pressure Range: -0.1 to 1 MPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Initial Value PSI, Option 2: None, Option 3: Operating Manual Booklet, X Options: Wetted Parts: Stainless Steel 316L

Rated Pressure Range: -0.1 to 1 MPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Booklet, X Options: Lead Wire Length 3m

Rated Pressure Range: 1 to -101 kPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: Panel Mount Rear or Bottom Ported, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: Wetted Parts: Stainless Steel 316L

Rated Pressure Range: -100 to 100 kPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: W/Unit Display Switching Function, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Boklet, X Options: Lead Wire Length 3m

Rated Pressure Range: 1 to -101 kPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: None, Option 3: Operating Manual Boklet, X Options: Wetted Parts: Stainless Steel 316L

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/4, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/4, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/4, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

The ISE80 series is a digital pressure switch designed to measure fluids such as tap water, hydraulic fluid, silicon oil, lubricant, fluorocarbon, argon, ammonia, carbon dioxide, air-containing drainage and nitrogen. 

Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only)

Pressure Range: ISE77G (0 to 10 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)

Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H]), Operation Manual/Calibration Certificate: Y (None)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Pressure Range: ISE77G (0 to 10 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE76G (0 to 5 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]