x 1.25 depth 14 32 40 75 22 16 18 107 8.6 140 50 34.5 160 14 depth 10 M10 x 1.5 depth 18 37 M8 x 1.25 depth 16 45 110 22 19 23 142 10.5 170 80 37 194 17 depth 12 M12 x 1.75 depth 21 42 M10 x 1.5 depth 20 Bore size (mm) W Z Y X WH W V U T S R Q O N M L K J I P 20 25 32 40 50 30 140 80 30 23 36 40 86 12 26 12 21 M6 x 1 25 38 80 60 44 25 M5 x 0.8 30 153 80 37 25 44 47 98 13 31 12 21 M6 x 1
A B C D E EE F G H J K Applicable model Y200T-D 3.2 67 29 51 24 33 11.5 5.5 15.5 3.5 30 AFF/AM/AMD/AMK20 Y300T-D 4.2 85 42.5 67.5 35 14 7 20 6 41 AFF/AM/AMD/AMK30 Y400T-D 5.2 115 50 85.5 40 55 18 9 26 7 50 AFF/AM/AMD/AMK40 Part no.
A (L) (H) 17 85 (Same measurement on 2 sides) 40 (M10) 400.05 (8) 40 (M10) 400.05 (8) 15 2 3 3 (t=1 x 1, t=0.5 x 2) Depth 13 2 x 8H7 2 sides x (Same measurement on 2 sides) 40 (when the shims are attached) 2 sides x 2 x M10 x 1.5 40 (M10) 400.05 (8) Depth 15 (Same measurement on 2 sides) With shims 56 10.5 10.5 32 P 71 The head side cylinder port (The clamp side port) 64 P The head side
Power clamp cylinder European type Symbol Bore size D1 6 6 6 6 8 8 8 8 D2 7 9 9 9 10.2 10.2 10.2 10.2 H 16 20 20 25 20 20 20 25 40 50 63 80 40 50 63 80 S Bore size 40 40 50 63 80 50 63 80 B For 40 of A015, S type only Offset Arm position A015 A045 Offset 15 Offset 45 D1 Right D2 H R Center D1 D2 C H Left D1 D2 L H 192 Power Clamp Cylinder Series CKZT Cylinder Specifications 40 50 63 80
Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 0.5 4 0.5 4 3 16 2 16 2 40 5 40 5 2 1 Pin no.
86.5 8.6 M8 x 1.25 depth 16 16 104 19 75 37 40 160 50 140 30 16 17 depth 12 37 95 10.5 M10 x 1.5 depth 20 19 22 142 110 42 45 80 35 194 170 19 Data J K L H I GR O GK GL GQ N S P GD M Q R Bore size (mm) 20 25 32 40 M8 x 1.25 depth14 80 5.5 60 3.5 93 35 4 4 25 26 M5 x 0.8 54 50 14 105 M6 x 1 M10 x 1.5 depth18 95 9 70 4 103 40 7 7 32 31 M5 x 0.8 62 125 60 M8 x 1.25 14 M10 x 1.5 depth18 95 9
86.5 8.6 M8 x 1.25 depth 16 16 104 19 75 160 50 140 30 40 37 16 17 depth 12 37 95 10.5 M10 x 1.5 depth 20 142 19 22 110 194 80 170 35 45 42 19 Data P GD GK GL GQ GR H I J K L M N O Q R S Bore size (mm) 20 25 32 40 M8 x 1.25 depth14 80 5.5 60 3.5 93 M5 x 0.8 54 4 4 35 105 50 25 M6 x 1 14 26 M10 x 1.5 depth18 95 9 70 4 103 M5 x 0.8 62 7 7 40 125 60 32 M8 x 1.25 14 31 M10 x 1.5 depth18 95 9
Arrange so that maximum load will be 40% for theoretical force of 20, 50% for 32, 55% for 40 and 60% or less for 50, respectively.
32 mm 40 40 mm 45 45 mm 50 50 mm 56 56 mm 63 63 mm 67 67 mm 80 80 mm 85 85 mm 100 100 mm For applicable auto switches, refer to the table below.
Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 4 0.5 0.5 4 3 16 16 2 2 40 40 5 5 2 1 Pin no. Pin description 1 DC(+) 2 NC/Analog output 3 DC() 4 OUT 31
1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
Standard Strokes Bore sizes (mm) Standard strokes (mm) 20 & 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 32 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75 40, 50, 63, 80, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Made to Order Pages 22 to 24 Manufacture of Intermediate Stroke Cylinders Hydraulic Fluid Compatibility Intermediate strokes in 5mm increments can be manufactured by installing spacers
N S + Stroke H B ZZ + Stroke Stroke range Bore size (mm) I J K M B D C E KA GA GB H 40 50 63 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 10 14 14 45 55 68 21 26 32 36 46 53 34.5 40 46.5 40 45 50 46 55 66 59 71 82 23.5 28 34.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) MM XA XL Y ZZ MA MB MC N P S 40 50 63 M6 x 1.0 M8 x 1.25 M8 x 1.25 12 16 16 6 6 6 9.5 12.5 15 178 195 221 18
Series CBQ2 Allowable Kinetic Energy Allowable Rod End Lateral Load 0.5MPa 0.4MPa With rubber bumper With auto switch (lateral resistance) 200 100 100 50 50 40 30 Allowable lateral load W (N) 63 20 Load weight kg 50 10 63 40 32 10 5 4 3 50 5 2 40 1 0 10 20 30 40 50 60 70 80 90 100 32 Stroke St (mm) 1 50 100 200 500 300 Maximum speed mm/s (Mounting orientation: Horizontal) W
7. * The seal kit includes 2 cushion seals, 1 rod seal, 1 piston seal, and 2 tube gaskets. 1.7-27 Series MBlQ Basic/(B) G G Cushion valve W V Port 2-Rc(PT)P MM D E MB Effective thread 2 X 4-J lC lB MA A K F N N S + Stroke H ZZ + Stroke (mm) Stroke range Width across flats Bore (mm) Effective thread length A D Ee11 F N G P MA S MB V J W K H ZZ MM lC lB 32 40 50 63 80 100 22 30 35 35 40 40
-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.
DC AC, DC 60 40 1 80 60 10(1) 40 60 60 40 Maximum Minimum 10 5(2) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E, N, P etc. in parentheses are option symbols.
(-B is not necessary) Note 3) Specify -K for wiring specification for cases below. (Except L kit) All single wiring Single and double mixed wiring. When there are stations which do not require wiring (e.g. individual SUP spacer), specify the wiring specification in the manifold specification so that the number of solenoids is the maximum number of solenoids or less.
Note 3) This data is considered typical but not guaranteed. 10Leakage test result 100 5 10 Time [min] e e a a l l k k w w 2 a a 1 O-ring seals separate vacuum and atmosphere. Employs a magnetically coupled rodless cylinder with no air leakage from moving parts. o o g g L L e e Static O-ring seals are used for all the seals between vacuum and atmosphere.