new AF modular style air filter combines the element and bowl in one piece, making element replacement easy.? There is a maximum 46% reduction in size, reducing required maintenance space.? The AF bowl (size 30 and 40) is covered with a transparent bowl guard, allowing 360 monitoring.??The modular design of the AF allows connection with other SMC air preparation equipment.

Fittings & Tubing Air Cylinders Rotary Actuators 2 x M2.5 x 0.45 thread depth 3 Operating port 2 x M3 x 0.5 Vacuum suction port M5 x 0.8 2 6 J I 5 Max. 10.5 (With stroke adjuster at retraction end) 4 7 0.5 19 3 5.5 5.5 5.5 3 3 6.5 2 x M2.5 x 0.45 thread depth 3 12.5 K Stroke adjuster at extension end Stroke adjuster at retraction end (With stroke adjuster at extension end) 18 N x M3 x 0.5

at retraction end) 12 32 31 18 24 9.5 3H9 depth 2.5 +0.025 0 F 10 N 1 x F 2-M3 x 0.5 thread depth 5 2 27 3H9 depth 2.5 +0.025 0 21 M 20 Z ZZ (NN1) x H G H 5.5 11 11 5.5 B A 3.2 6.5 7 7 12 1 4 NN-M4 x 0.7 thread depth 8 B A 3H9 depth 2.5 +0.025 0 3H9 depth 2.5 +0.025 0 HA GA Section AA Section BB (mm) Model F 20 30 20 28 38 ZZ 64 74 84 106 122 M 42 52 62 84 100 Z 41.5 51.5 61.5 83.5 99.5 K

Light/surge voltage suppressor U R With light/surge voltage suppressor With surge voltage suppressor Back pressure check valve K Nil None Built-in Rated voltage The built-in back pressure check valve type is applicable to the 10-SV1000 series only.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Plug Lead Plug-in Cassette P. 2-4-12 P. 2-4-14 P/J kit Series VQ0 P R SMC P. 2-4-38 P. 2-4-42 P. 2-4-46 P kit Series VQ1000 P. 2-4-38 P. 2-4-42 P. 2-4-46 P kit Series VQ2000 P. 2-4-38 P. 2-4-42 P. 2-4-46 P kit Series VQ1000 P. 2-4-76 P. 2-4-78 P. 2-4-

46 LB 27 31 36 46 46 LA 35.5 41 47 62 62 LA 35 41 46 62 62 L 52.5 59 67 81 84 L 52.5 59 67 81 84 ZZ 115.5 127 137 171 175 Model MU25 MU32 MU40 MU50 MU63 Model MU25 MU32 MU40 MU50 MU63 Applicable pin 8 10 10 14 14 9 11 13 16 16 8 10 10 14 14 9 11 13 16 16 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.2

46 LB 27 31 36 46 46 LA 35.5 41 47 62 62 LA 35 41 46 62 62 L 52.5 59 67 81 84 L 52.5 59 67 81 84 ZZ 115.5 127 137 171 175 Model MU25 MU32 MU40 MU50 MU63 Model MU25 MU32 MU40 MU50 MU63 Applicable pin 8 10 10 14 14 9 11 13 16 16 8 10 10 14 14 9 11 13 16 16 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.2

10mm/s LESH8R LESH16R LESH25R J K J K J K 4 6 15 23.5 43 77 7 10.5 25 39 71.5 128.5 [N] 10 15 35 55 100 180 *20%F.S.

Auto switch and switch spacer are shipped together with the product, but not assembled. 1505 CY1S Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke end) Switch rail T-slots Switch rail T-slots Lower corner of the slot Lower corner of the slot (Depth 0.3 mm) (Depth 0.3 mm) K K B A D C Note 1) The minimum stroke when 2 in-line auto switches are mounted as

No.EX-OMN0037CN-A / EX600-AXA EX600-AYA EX600-AMB SMC 3 9 10 12 12 14 15 15 16 16 LED 18 19 19 24 25 25 26 26 LED 27 28 28 32 33 33 34 34 LED 36 37 37 44 -1No.EX-OMN0037CN-A 45 46 46 46 46 46 47 -2No.EX-OMN0037CN-A (ISO/IEC)(JIS) 1 2 *1 ISO 4414: Pneumatic fluid power -General rules relating to systems.

CL Y-12 Y-14 Y-16 125 140 160 25 32 25 +0.084 0 +0.3 +0.1 0.1 0.3 46 100 M30 x 1.5 27 42 E1 NX NZ +0.3 +0.1 0.1 0.3 28 36 28 +0.084 0 48 105 M30 x 1.5 30 47 CL1 +0.3 +0.1 0.1 0.3 32 40 32 +0.100 0 55 110 M36 x 1.5 34 46 MLGC U1 L1 CNG RR1 MNB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200

Active face A (upper switch) becomes covered at open limit of travel and face K (lower switch) at closed limit.

-X CXS -R 10 15 20ZZ SS Z Data (Z) Manual lever insertion 1.7 K KK Hexagon (O) (Z) (mm) O K Model CXS10-R CXS15-R Width across flats 12 6.5 8.5 Width across flats 13 (mm) Symbol ZZ Z SS KK Stroke 50 40 30 20 50 10 10 50 40 30 20 40 30 20 10 10 20 50 40 30 Model CXS10-R CXS15-R 24.5 40 50 142 132 117 107 125 30 115 100 80 19.5 97 90 45 Dimensions other than those listed above are the same

PV SV 5.23 Communication Function HRSH Series 5-84 HRX-OM-Q026 Chapter 5 Display and Setting of Various Functions 46. Select a function with [] key or [] key, and press [SEL] to enter.

H A A W H H Symbol: A25 Symbol: A26 Symbol: A27 Symbol: A28 Symbol: A29 DA 30 MM MM DA 30 DA 30 30 MM L W MM A L H AL H LB K A AL A H L A H T AL L K H MM Symbol: A30 30 MM W A T H 84 Simple Specials Series CP96/C96 Symbol Change of Trunnion Bracket Mounting Position 2 -XC14 Series C85 Series CP96 Series C96 Series C55 The position for mounting the trunnion pivot bracket on the cylinder

(Same side) A HS Number of switches 20 25 32 40 50 63 80 100 31.5 26 24 Mounting surface Port surface Port surface Port surface 31.5 28.5 24 32.5 33 25 37 36.5 28 45.5 42 36 45.5 48.5 36 Switch type 56 57.5 46 Minimum stroke (mm) 10 15 75 57 68 46 15

L M N O P Q R K L M N O P Q Part no.

Double clevis pin and double knuckle XC27 pin made of stainless steel 70C J Nylon tarpaulin XC29 Double knuckle joint with spring pin 110C K Heat resistant tarpaulin XC30 Front trunnion Max. ambient temperature for rod boot itself. XC35 With coil scraper Mounting Bracket Part No.