1 Chrome molybdenum steel Hexagon socket head bolt Chrome molybdenum steel Hexagon socket head bolt Rare earth magnet Magnet B !
1 Chrome molybdenum steel Hexagon socket head bolt Chrome molybdenum steel Hexagon socket head bolt Rare earth magnet Magnet B !
W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/
B dimension is 77.5 mm. Example Calculation:25, B dimension 27.5 mm (without auto switch) 27.5 (B dimension) + 50 (st) = 77.5 (mm) D-X 1169
Rotary Actuator CRA1 Series Rack & Pinion Type/Size: 30, 50, 63, 80, 100 RoHS How to Order B S 50 90 Z CRA1 With auto switch CDRA1 B S 50 90 M9BW Z Built-in magnet Number of auto switches Air cushion Mounting B Basic type L Foot type* Nil None C* With air cushion Nil 2 pcs. S 1 pc.
(Example) RDLQL40-50-B Locking direction F B Extension locking Retraction locking Indicator light Load voltage Auto switch model Lead-wire length (m) Type Special function Electrical entry direction Wiring (output) Applicable load Pre-wired connector 0.5 (Nil) 3 (L) 5 (Z) None (N) 1 (M) DC AC In-line Perpendicular M9N M9P M9B M9NW M9PW M9BW M9NA M9PA M9BA F79F M9NV M9PV M9BV J79C M9NWV M9PWV
Replacement Actuator (Cylinder) CY1F R B 10 Stroke Note) -XB10 or -XB11 is not required at the end of the part number for intermediate or long strokes.
In this case, the rigidity of the machinery should also be examined. 9 - 7) How to order 25A D B 125 100 D-M9* C S2 Auto-switch Stroke Bore size Mounting bracket Built-in magnet Secondary battery production facility Air Cylinder Built-in magnet Bore size D Built-in magnet 125 125mm Nil Without magnet 140 140mm 160 160mm Mounting B L *Refer to Maximum stroke table(P5 Table 1) F G Auto-switch
Compact Cylinder: Guide Rod Type 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 Series CQM How to Order B 20 10 CQM M9BW B 20 10 CDQM With auto switch Number of auto switches With auto switch (Built-in magnet) Nil S n 2 pcs. 1 pc. n pcs.
Compact Cylinder: Standard Type Double Acting, Single Rod Series CQS 12, 16, 20, 25 How to Order B D 30 20 CQS M9BW B D 20 30 CDQS With auto switch Made to Order Refer to page 552 for details.
2 Compact Cylinder: Standard Type Double Acting, Single Rod Series CQ2 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 How to Order Without auto switch B 20 30 D CQ2 B 20 30 D J79W S CDQ2 With auto switch Built-in magnet Number of auto switches Mounting style 2 pcs. 1 pc. n pcs.
Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore Size: 25mm, Port Thread: Rc, Stroke A: 100mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen.
B 0.2 A 0.2 Bore size [mm] A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 7.
Doc. no.MB**-OM0072P-B PRODUCT NAME Air cylinder MODEL / Series / Product Number */ Contents Safety Instructions P2 1. Specifications P4 1-1. Specifications 2. Installation and Handling P4 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Allowable kinetic energy 2-7. Air cushion 2-8.
DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) A 9 13 11 13.5 B 6 8.5 11.5 14.5 A 9.5 13.5 11.5 14 B 6.5 9 12 15 A 6.5 10.5 8.5 11 B 3.5 6 9 12 C 8 12 10 12.5 D 5 7.5 10.5 13.5 C 12 16 14 16.5 D 9 11.5 14.5 17.5 C 11 15 13 15.5 D 8 10.5 13.5 16.5 32
When auto switches D-M9/M9W/Y59 D-M9A D-Y7, Y7W are used A B L Auto Switch Hysteresis MHZ When auto switches D-M9V/M9WV/Y69 D-M9AV D-Y7V, Y7WV are used Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc. MHF A B MHL L MHR MHK MHS Max.
DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 3.5 6 9 12 A 6.5 10.5 8.5 11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32
Lead wire length (m) Auto switch model Indicator light Electrical entry direction Load voltage Special function Electrical entry Wiring (Output) Applicable load Pre-wired connector 5 (Z) Type 0.5 (Nil) 1 (M) 3 (L) DC AC Perpendicular In-line M9N M9P M9B M9NW M9PW M9BW M9NV M9PV M9BV M9NWV M9PWV M9BWV 3-wire (NPN) IC circuit Solid state switch 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC
B dimension is 133 mm. Applicable example 2
Compact Cylinder with Air Cushion 20, 25, 32, 40, 50, 63, 80, 100 Series RQ How to Order RQ B 32 50 50 RDQ B 32 M9BW With auto switch With auto switch (Built-in magnet) Made to Order For details, refer to page 775. Mounting bracket Number of auto switches Through-hole (Standard) Rod side flange style B F 2 pcs.