SMC Corporation of America
Elite Part Number Search
Search Results "AC30C-N03-V-Z-D"

NFB MC CNP1 NFB MC L1 L1 Three phase 200 to 230 VAC Single phase 200 to 230 VAC CNP3 CNP3 L2 L2 U U U Motor U Motor L3 L3 V V V V M M N () N W W W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and L2 terminals, with nothing connected

Applicable Auto Switch/Tie-rod Mounting Indicator light Load voltage Applicable load Lead wire length (m) Auto switch model Wiring (Output) Tie-rod Electrical entry Type Special function Band 0.5 (Nil) 3 (L) 5 (Z) DC AC mounting mounting 3-wire (Equiv. to NPN) A56 IC 5 V A53 A54 A67 A64 A59W Yes A33 A34 A44 100 V, 200 V 200 V or less 12 V 2-wire 5 V, 12 V 12 V Relay, PLC IC 24 V Reed

d Dd9 D C t m t l m L H1 B1 Metric (mm) (mm) Part no.

Auto switch mounting screw Hysteresis Auto switch Auto switch reset position (OFF) Auto switch operating position (ON) Tightening torque of auto switch mounting screw (Nm) Air gripper model Hysteresis degree (Max. value) MHT2-32D MHT2-40D MHT2-50D MHT2-63D Auto switch model Tightening torque D-M9(V) D-M9W(V) D-M9A(V) D-A9(V) 3 0.05 to 0.15 3 3 0.10 to 0.20 3 651 A Series MHT2 In addition

The purity class of compressed air quality based on ISO8573-1:2010 2 : 6 : 3 Solid particle Moisture Oil Max number of particles per m3 Oil concentration (mg/m3) 0.1 < d 0.5 0.5 < d 1.0 1.0 < d 5.0 Pressure dew point Particle size d (m) Class Class (oC) at air pressure Class of 0.7 MPa 1 20,000 400 10 1 -70 1 0.01 2 400,000 6,000 100 2 -40 2 0.1 3 Not specified 90,000 1,000

(IEC 60417-5032-1) How to see the serial number Z o 001 (Jan 2021) X R 001 Year Symbol Remarks Month Symbol Remarks Serial no. 1 o Repeated from O to Z in alphabetical order, with O for January and Z for December 2021 Z Repeated from A to Z in alphabetical order 2022 A 2 P 2023 B 3 Q Fig. 1-1 Position of the product label HRL Series 1.4 Product Label 1-3 HRX-OM-Y098 Chapter 1 Safety Instructions

1 V 1.8 V 5 V Current output 4 mA 7.2 mA 20 mA (PF3W721-U30) A B C Voltage output 1 V 1.48 V 5 V Current output 4 mA 5.92 mA 20 mA Rated flow [L/min] Sensor model Minimum Maximum PF3W704 0.5 4 PF3W720 2 16 PF3W740 5 40 PF3W711 10 100 PF3W721-12/14 50 250 PF3W721-U30 30 250 Analogue output (Fluid temperature) A B C D Voltage output 0.6 V 1 V 5 V 5.4 V Current output 2.4 mA 4 mA 20 mA 21.6

Lead wire length (m) Load voltage Auto switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols

Relay, PLC Yes Yes No 24 V Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12 V 3-wire (NPN equivalent) A96V A96 5 V IC circuit DGrommet A93V A90V A93 A90 100 V Relay, PLC 24 V 12 V 2-wire IC circuit 100 V or less -X Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other

D-M9A D-M9AV Open MHY2-10D 3 5 1 3 Closed Open MHY2-16D 3 5 1 3 Closed Auto switch reset position (OFF) Open MHY2-20D 3 1 Closed Open MHY2-25D Hysteresis 1 Closed Hysteresis Auto switch operating position (ON) Auto switch operating position (ON) Auto switch reset position (OFF) D-M9(V) D-M9W(V)/M9A(V) 2 Finger fully closed MHY2 -10D 4 Finger fully open 2 Finger fully closed MHY2 -16D

l Cross section C-C #i .. :: fl ffi -i+-sLJ rr Model D f G, I K L !,!

Reed switches Solid state switches D-F9N (V) D-A90 (V) D-F9NW (V) DC (+) Brown [Red] DC (+) Brown [Red] Contact protection box OUT () Brown [Red] Reed switch Main switch circuit Main switch circuit OUT Black [White] OUT Black [White] CD-P11 CD-P12 OUT ( ) Blue [Black] DC () Blue [Black] DC () Blue [Black] D-A93 (V) D-F9P (V) D-F9PW (V) DC (+) Brown [Red] DC (+) Brown [Red] Brown [Red] LED

Mounting Position (mm) Mounting Height (mm) CP95 Auto switch model D-G5NTL D-G59F D-H7C D-G5BAL D-C7,C8 D-H7 D-H7W D-H7F D-H7BAL D-B5,B6 D-B59W D-G5, K5 D-G5W D-K59W D-B5,B6 D-C7,C8 D-C73C D-C80C D-H7W D-H7F D-H7BAL D-G5 D-K5 D-G5NTL D-B59W D-H7 D-H7C C95 D-C73C D-C80C D-G5W, K59W D-G59F D-G5BAL C92 Bore B 18 (26) 18 (26) 19 (27) 21.5 (30.5) 26 (38) 26 (38) B 19.5 (27.5) 19.5 (27.5) 20.5

PEND Petroleum CW-6H Water-glycol, Emulsion For 2 1/2B, 3B CW-6H-W Phosphoric ester CW-6H-V Petroleum D-73H Water-glycol, Emulsion For 1/2B to 1B D-73H-W Phosphoric ester D-73H-V Petroleum D-74H Cap Water-glycol, Emulsion For 1 1/4B to 2B D-74H-W Phosphoric ester D-74H-V Petroleum D-75H Water-glycol, Emulsion For 2 1/2B, 3B D-75H-W Phosphoric ester D-75H-V 506 Suction Guard FHG Series How

Mounting dimensions of extension fitting One-touch Fittings (KQ2H/KQ2S/KQ2L/KQ2W/KJH/KJS/KJL/KJW) Auto switch model D-M9(V) D-M9W(V) D-F8 D-M9A(V) 5.9 S 10 O Width across flats 5 12 19.5 Interference between the auto switch and the fitting When mounting extension fittings, first, tighten it by hand, then give it an additional 1/4 turn with a wrench. 924 Air Gripper MHZ2 1122Dimensions L

E R NZM V A C U U M E J E C T O R D I M E N S I O N S W I T H VA LV E A N D VA C U U M S W I T C H W I T H V A LV E S A N D S W I T C H (N)ZM HK5LZ V O LTA G E 5 24VDC 6 12VDC N O Z Z L E D I A M E T E R 05 0.5mm 07 0.7mm 10 1.0mm 13 1.3mm V A C U U M S W I T C H Nil Without E15L Solid State (NPN) E55L Solid State (PNP) M21L Reed M15L Non-Contact S Y S T E M C I R C U I T Supply Exhaust P

2-wire 5 V, 12 V Reed auto switch Solid state auto switch 12 V IC circuit Diagnostic indication (2-color display) 5 V, 12 V Relay, PLC Yes Grommet 24 V 12 V IC circuit 5 V, 12 V Water resistant (2-color indication) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V 3-wire (NPN equiv.)

Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C HRS-R Series 3.3 Installation 3-19 HRX-OM-W058 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.