01 M5 x 0.8 Rc(PT) 1/8 (port A) VKF332 (with bracket) Body ported (single type) 5 G M5 Body ported (for manifold) 5 G M5 VKF333 5 G 01 VKF334 Base mounted Light/Surge voltage suppressor Valve option Port size For vacuum For low power consumption For vacuum/low power consumption For long loading time 01 Nil V Y Rc(PT) 1/8 (with sub plate) Without sub plate None With surge voltage suppressor

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H A function to store the accumulated flow value in the products internal memory. The flow value will be stored at a set time interval of either 2 or 5 minutes.

For EE (ZSE4E) 24 V 12 V 6 V 5 V 3 V 5 6 V S R Lead wire length 0.5 (2.9) m NPN output Analog output PNP output 27 26 67 Lead wire length 0.5 (2.9) m Lead wire length 0.5 (2.9) m Not required for Nil, vacuum adapter (GN) and vacuum pressure gauge (G).

Apparent power (VA) Volt-ampere is the product of voltage (V) and current (A). Power dissipation (W): For AC , W = V/A cos. For DC, W = V/A (Note) cos shows power factor. LVD LVQ 2. Surge voltage The surge voltage is a high voltage generated momentarily when cutting the power supply. LQ 3.

Lead wire length (m) Load voltage Auto switch model Electrical entry direction Pre-wire connector Special function Type Electrical entry Indicator light Wiring (Output) 3 (L) 5 (Z) Applicable load 0.5 (Nil) AC DC Perpendicular In-line M9N M9P M9B F8N F8P F8B 3-wire (NPN) Solid state switch Relay, PLC 12 V 24 V Yes Grommet 3-wire (PNP) 2-wire Auto switches marked with are produced

9.4.15 HRL200-W-40-T2 CH1 .9-19 9.4.16 HRL100/200-W-40-T2 CH2 .9-19 9.5 Pump Capacity . 9-20 9.5.1 HRL100-A/W-40 CH1 .9-20 9.5.2 HRL200-A/W-40 CH1 .9-20 9.5.3 HRL300-A-40 CH1 .9-21 9.5.4 HRL-A/W-40 CH2 .9-21 9.5.5 HRL100/200/300-A/W-40-T2 CH1 .9-22 9.5.6 HRL300-A-40-T3 CH2 .9-22 9.6 Types of Hazard Labels . 9-23 9.6.1 Positions of danger warning label .9-24 9.7 Standards . 9-25 9.8 Daily

MULTI COUNTER:CEU5 UP M/C COUNT PRESET FUNC. LEFT RIGHT DOWN SEL.

Compact Vacuum Ejector Series ZA How to Order Ejector Unit ZA1 1 07 K1 P1 5 L 0 1 Nozzle nominal size Vacuum (V) port 05 07 0.5 0.7 Applicable tubing O.D. Part no. KJS23-M5 KJS04-M5 KJL23-M5 KJL04-M5 Symbol 1 2 4 5 3.2 (Straight) 4 (Straight) 3.2 (Elbow) 4 (Elbow) Solenoid valve combination (Refer to Table (1).)

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Type Special function Electrical entry Wiring (Output) M9N P P P p p IC circuit 3-wire (NPN) Solid state auto switch 5 V, 12 V 3-wire (PNP) M9P P P P p p 2-wire 12 V M9B P P P p p 3-wire (NPN) 5 V, 12 V M9NW P P P p p IC circuit 3-wire (PNP) M9PW P P

K L M Size 40 50 Actuator port direction Flange side Left flange surface Rear flange surface Right flange surface Right flange surface Left flange surface E H V I G L H A V V M A C U U Flange side e Temperature specifications/Heater r Auto switch type Symbol Nil H0 H4 H5 Temperature 5 to 60C Heater None None With 100C heater With 120C heater Symbol Nil Auto switch part no.

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H A function to store the accumulated flow value in the products internal memory. The flow value will be stored at a set time interval of either 2 or 5 minutes.

MXQ MXF m m MXW MXP MG MGP MGQ MGG 25/50 stroke Over 50 stroke 200 200 MGC P=0.5MPa P=0.5MPa MGPS80 MGPS80 MGF 100 100 Load weight m (kg) Load weight m (kg) CY1 MGPS50 MGPS50 50 50 MY1 40 40 30 30 20 20 10 20 30 40 50 100 200 10 10 20 30 40 50 100 200 10 Eccentric distance l (mm) Eccentric distance l (mm) 3.17-31 Series MGPS Construction !6 o i !0 !8 r !1 t !9 !2 !6e q u !4 w !7 !3 @0 !

Reed switch Solid state switch 5 V IC circuit Z76 Grommet Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F 100 V 12 V Y es Relay, PLC 24 V 2-wire 100 V, 200 V Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC circuit Grommet 12 V 100 V, 200 V 2-wire 3-wire (NPN) 3-wire (PNP) IC circuit Relay, PLC 5 V, 12 V Diagnostic indication

Note q Lead wire and M12 connector (3 m), Straight ZS-37-A 1 pc. w Lead wire and M12 connector (3 m), Right angle ZS-37-B 1 pc. e Assembly-type connector PCA-1557743 1 pc. r Adapter with restrictor Rc1/4 ZS-31-X175 1 pc. t Adapter with restrictor Rc1/8 ZS-31-X188 1 pc. y Orice M5 ZS-48-A 1 pc. u q + e ZS-37-A-X448 The lead wire and connector are Nil Voltage output type 1 to 5 V 28 Current

Approx. 1.1 mm Insulator Colours Brown, blue, black, white Sheath Finish O.D. 4 71 No.PF-OMU0002-D Characteristics data Flow rate/ Analogue output 0 L/min A 2 B 0 L/min C 2 D Voltage output (1 to 5 V) 1 1 V 1.04 V 5 V Voltage output (0 to 10 V) 1, 3 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range *4 Maximum value of rated flow range PF3A703H 30

0 IC-0(Built-in sensor type) IC-1(External sensor type) No. q w e r Description Note Breathing port (M3 x 0.5 x 9.5) Breathing port (M3 x 0.5 x 9.5) Power supply, 10 bit input cable 13 cores, O.D. 6.8 mm, 1 m length Cable for 4 point switch output 5 cores, O.D. 6 mm, 1 m length q q Pneumatic regulator connection cable 3 cores, O.D. 3.4 mm, 1 m length Cable for external sensor Note 1) Keep

How to Order 2 2 0 0 01 M AS Option Body size None With seal Nil S 1 2 2 Meter-out Meter-in M5 standard 1/8, 1/4 standard Type Direct cylinder elbow type Control type M5 and U10/32 are not available with seal.

Series: 25A-PFM5, Rated Flow Range: 10 [0.2 to 10 (5) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Operation Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Lead Wire: W (w/Lead Wire w/Connector, Rubber Cover for Connector, Silicone Rubber)