Flow Range: 10 (1~10l/min), Thread: F (G thread), Port Size: 01 (Port Size 1/8)
Flow Range: 10 (1~10l/min), Thread: F (G thread), Port Size: 01 (Port Size 1/8), Wiring Specification: N (w/o Lead Wire)
Flow Range: 10 (1~10l/min), Thread: F (G thread), Port Size: 01 (Port Size 1/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 10 (1~10l/min), Thread: F (G thread), Port Size: 02 (Port Size 1/4)
Flow Range: 10 (1~10l/min), Thread: F (G thread), Port Size: 02 (Port Size 1/4), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 11 (10~100 l/min), Thread: F (G thread), Port Size: 03 (Port Size 3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 11 (10~100 l/min), Thread: F (G thread), Port Size: 03 (Port Size 3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 21 (20~200 l/min), Thread: F (G thread), Port Size: 03 (Port Size 3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 21 (20~200 l/min), Thread: F (G thread), Port Size: 03 (Port Size 3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 10 (1), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature