SMC Corporation of America
Elite Part Number Search
Search Results "NCDA1B400-1000-XC6"

1000 0 0 0 100 0 0 0.1 2 INC 50 10.00 1000 1000 0 0 0 100 0 0 0.1 () 1No.1(IN0ON) / 2DRIVEON (2)(5)(10)(13) No.1 DRIVE (1) No.

Move Speed Position Accel Decel PushingF TriggerLV PushingSp Moving F Area1 Area2 In posn mm/s mm mm/s2 mm/s2 mm/s mm mm mm 0 ABS 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 ABS 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 ABS 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 Caution Writing of the step data should be performed while the electric actuator is stopped. 39 - Details of step data

VAC for 1 min. between external terminal and case Withstand voltage Resistance 50 M (500 VDC) between external terminal and case Insulation resistance 10 to 500 Hz at whichever is smaller: 1.5 mm amplitude or 98 m/s2 acceleration Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Noise resistance 200 g 240 g Weight

500 1000 1500 2000 0 500 1000 1500 2000 mm mm Installation distance [mm] Installation distance [mm] 6-3.

Move mm/s2 mm/s2 mm/s mm mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 28 - Details of step data Setting name Range Description No. 0 to 63 Number of the step data. The setting to specify the coordinate system for the target position.

Work load [kg] Work load [kg] 40 30 Lead 8: LEY32DB Lead 10: LEY32B 30 20 24 19 Lead 16: LEY32DA 20 Lead 20: LEY32A 10 12 9 10 0 200 400 600 800 1000 1400 1200 0 0 200 400 600 800 1000 1200 0 Speed [mm/s] Speed [mm/s] LEY63 (Motor mounting position: Top/Parallel, In-line) 120 Lead 2.86: LEY63L (Top/Parallel type only) 100 Lead 5: LEY63C Work load [kg] 80 Area where the regeneration option

Cylinder speed 1000 mm/sec. PLC response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

V output 50005 V output (3) The resolution from 1 to 5 V is 1/1000 based on the calculation. (5 V 1 V) / (5000 1000) = 1/1000 Scale set value (AD value) Output signal range (a to b) Voltage [V] Current [mA] Decimal number 0 to 10 1 to 5 0 to 5 0 to 20 4 to 20 Scale upper limit -32766 to 32767 10 5 5 20 20 Scale lower limit -32767 to 32766 0 1 0 0 4 : If the data format is scale conversion

6 1000 20 5 100 30 4 10 50 6 1000 5 5 100 15 4 10 30 6 1000 20 5 100 50 4 10 60 6 1000 10 5 100 40 4 10 50 6 1000 50 5 100 80 4 10 100 LEFS16 500 500 LEFS25 900 500 Please aspirate it from the port on both sides when aspirating 50 /min(ANR).

Movement Speed Position Acceleration Deceleration Force Value Area 1 Area 2 In pos force speed force mode mm/s (mm) mm/s2 mm/s2 (mm) (mm) (mm) mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0, 1 (E.g.) Flow chart Controller (1) Select Step No.1.

Movement Speed Position Acceleration Deceleration Force Value Area 1 Area 2 In pos force speed force mode mm/s mm mm/s2 mm/s2 mm mm mm mm/s 0 1 Absolute 100 50.00 1000 1000 0 0 0 100 0 0 0.1 2 Relative 50 10.00 1000 1000 0 0 0 100 0 0 0.1 (E.g.) Flow chart Controller (1) Select/input Step No.1.

Movement Speed Position Acceleration Deceleration Force Value Area 1 Area 2 In pos force speed force mode mm/s (mm) mm/s2 mm/s2 (mm) (mm) (mm) mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0, 1 (E.g.) Flow chart Controller (1) Select/input Step No.1.