SMC Corporation of America
Elite Part Number Search
Search Results "MXW20-150-M9PWL"

Pilot pressure range Ambient and fluid temperature (C) 0 to 60 (No freezing) Lubrication Required (Turbine oil, Class 1 lSO VG32 equivalent) VPA3165-06 VPA3145-03 Free Mounting orientation Impact resistance/Vibration resistance (m/s2) Note) 150/50 Note) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when

1 3 Port Air Operated Valve Series VZA200/400 Specifications SA Fluid Air 1 2 1 2 VZA4 2, 4 4 1 2 1 2 VZA2 2, 2 4 1 2 1 2 VZA4 2, 4 4 1 2 1 2 VA Operating pressure range (MPa) 0.1 to 1.0 0.15 to 1.0 VZA2 2, 2 4 0.1 to 1.0 0.15 to 1.0 SA Pilot pressure range (MPa) Impact/Vibration resistance (m/s2) Note) 150/50 VA Operating pressure Pilot pressure Note) Impact resistance: No malfunction from

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Not required Lubrication Unrestricted Mounting position 150/30 Impact/Vibration resistance (m/s2) (2) Body ported Dustproof Enclosure Note 1) Based on dynamic performance test, JIS B 8374-1981.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Impact/Vibration resistance (m/s2) Note 2) 150/30 Dustproof Enclosure Note 1) Based on dynamic performance test JIS B8374-1981 (Standard type: at coil temperature of 20C, with rated voltage, without surge voltage suppressor) Note 2) Impact resistance:

Push type (Non-locking) Unrestricted 150/50 Shock/Vibration resistance (m/s2) (2) Terminal no. 2 () Manual override Mounting orientation 48 VDC In the case of indicator light assembly Terminal no. 1 (+) 1.1 kg Weight For grommet type Note 1) Based on dynamic performance test JIS B 8374-1981.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 150/50 (5) Grommet, DlN terminal VT Standard 100, 200 VAC, 50/60 Hz; 24 VDC 220, 110, 48, and 24 VAC (50/60 Hz) 100, 48, and 12 VDC Coil rated voltage VP Option 15 to 10% of rated voltage Allowable voltage fluctuation Coil insulation type VG Class B or

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Coil rated voltage Terminal type VT Coil insulation type Class B or equivalent (130C) (3) Shock/Vibration resistance (m/s2) 150/50 (4) VP Note 1) If it is low temperature, dry air should be used.

Mounting orientation Unrestricted 150/50 m/s2 (2) Shock/Vibration resistance Enclosure Dustproof Grommet, Grommet terminal, Conduit terminal, DIN terminal 100, 200, 24 , 48 , 110 , 220 , 240 Electrical entry DC AC (50/60 Hz) Coil rated voltage (V) 24, 6 , 12 , 48 , 100 Allowable voltage fluctuation 15 to +10% of rated voltage 12.7 VA (50 Hz) 10.7 VA (60 Hz) 7.6 VA (50 Hz) 5.4 VA (60 Hz)

Lubrication Manual override Non-locking push type Mounting orientation Unrestricted 150/50 m/s2 Shock/Vibration resistance (2) Dustproof Enclosure Grommet, Conduit, Conduit terminal, DIN terminal 100, 200, 24 , 48 , 110 , 220 , 240 Electrical entry DC AC (50/60 Hz) Coil rated voltage (V) 24, 6 , 12 , 48 , 100 Allowable voltage fluctuation 15 to +10% of rated voltage 19 VA (50 Hz), 16 VA

Lubrication Manual override Shock/Vibration resistance (2) Enclosure Non-locking push type 150/50 m/s2 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.

02 SYA5000 3 position closed center 00 3 1 4 02 With sub-plate 3 8 With sub-plate 3 position exhaust center 03 4 3 position pressure center 5 5-2-3 2 Series SYA3000/5000/7000 Specifications Fluid Operating pressure range MPa Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 (0.7 x P + 0.1) to 0.7P: Operating pressure range 0.1 to 0.7 0.2 to 0.7 Max. 60 Non-locking push type Not required Unrestricted 150

Mounting orientation Free Impact/Vibration resistance (m/s2) (2) 150/50 Note 1) Use turbine oil Class 1 (ISO VG32). Note 2) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal is ON and OFF .

Refer to page 3-13-4.) 3 Required (Turbine oil Class 1 ISO VG32) Yes (Non-locking) Unrestricted 150/50 Silencer for pilot EXH (AN101-01) Operating pressure range (MPa) Ambient and fluid temperature (C) Max. operating frequency (Hz) Lubrication Manual override Mounting orientation Impact/Vibration resistance (m/s2) Accessory (Standard equipment) (1) (2) Note 1) This solenoid valve requires