Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 044 (7/16"), Stroke: 0050 (1/2"), Cushion: w/o Rubber Bumper, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Relay Tie-rod D-M9N-900 Yes Grommet Max.40mA Sequence mounting controller IC circuit DC4.528V , Relay Tie-rod D-M9NV-900 Yes Grommet Max.40mA Sequence mounting controller IC circuit DC4.528V , Relay Tie-rod D-M9P-900 Yes Grommet Max.40mA Sequence mounting controller IC circuit DC4.528V , Relay Tie-rod D-M9PV-900 Yes Grommet Max.40mA Sequence mounting controller Relay DC1028V , 2.5 Tie-rod D-M9B
Bore size(mm) 12 12mm 32 32mm Port thread type Auto switch 16 16mm 40 40mm Nill M5X0.8 12,16 Nill Without auto switch 20 20mm 50 50mm Rc Solid state M9B , M9BW 20 to63 25 25mm 63 63mm TN NPT Read switch A93 TF G *The minimum stroke autoswich Mounting and operating range are the same as standerd product. 2.
(P.29~32) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube.
DC AC 0.5 1 3 5 () (M) (L) (Z) M9NV M9N IC 3 NPN 5V 3 PNP M9PV M9P 12V 2 12V M9BV M9B M9NWV M9NV IC 3 PNP M9PWV M9PW 3 NPN 5V 12V 2 2 12V M9BWV M9BW 24V M9NAV M9NA IC 3 PNP M9PAV M9PA PLC 3 NPN 5V 12V 2 2 12V M9BAV M9BA 2 2 P3DW 3 NPN A96V A96 IC 12V 100V A93V A93 2 24V 5V 100V A90V A90 IC PLC 12V 0.5m D-M9N M 1m D-M9NM L 3m D-M9NL Z 5m D-M9NZ 1 17 - 7-2. -1516
(P.20) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Note 1) For the tightening of the mounting screws (M2.5), use a precision screwdriver with a handle diameter of approximately 5 to 6 mm.
(P.27 to 29) < Applicable Auto switches > Solid state switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed switch D-A90(V)A93(V)A96(V) How to mount and move the auto switch Fig. 8 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube.
Enclosure ii Standard: IEC60529, watertight: IP67(JISC0920) 35 - Table (12) Solid state auto switch specification Auto switch Indication Load voltage Applicable Wiring Electrical part no. light load (Output) entry (illuminated Perpendicular In-line when ON) DC5V,12V 3-wire (NPN) D-M9NV D-M9N DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PV D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B
Enclosure ii Standard: IEC60529, watertight: IP67(JISC0920) 31 - Table (13) Solid state auto switch specification Auto switch Indication Load voltage Applicable Wiring Electrical part no. light load (Output) entry (illuminated Perpendicular In-line when ON) DC5V,12V 3-wire (NPN) D-M9NV D-M9N DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PV D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B
.) < Applicable Auto switches > Solid state auto switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) D-P3DW Reed auto switch D-A90(V)A93(V)A96(V) Figure 4.How to Mount and Move the Auto Switch (1) Fix it to the detecting position with a set screw by installing an auto switch mounting bracket in cylinder tie-rod and letting the bottom surface of an auto switch mounting
(The tightening torque of the M3 screw must be 0.6 to 1Nm.) (5) The detection position can be changed under the (5) The detection position can be changed under the conditions in step 3. conditions in step 3. 12 < Applicable Auto switches > Solid state auto switch D-M9N, M9P, M9B, M9N , M9PV, M9BV D-M9NWM9PWM9BWM9NW M9PWVM9BWV Caution (1) Ensure that the tightening torque is within the specified
.) < Applicable Auto switches > Solid state auto switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed auto switch D-A90(V)A93(V)A96(V) Figure 4.
.) < Applicable Auto switches > Solid state auto switch D-M9N(V)M9P(V)M9B(V) D-M9NW(V)M9PW(V)M9BW(V) D-M9NA(V)M9PA(V)M9BA(V) Reed auto switch D-A90(V)A93(V)A96(V) Figure 4.How to Mount and Move the Auto Switch (1) Fix it to the detecting position with a set screw by installing an auto switch mounting bracket in cylinder tie-rod and letting the bottom surface of an auto switch mounting bracket