Specifications Table. 6-1 Specifications Description Item EX245-SPN1 EX245-SPN2 General Dimensions (W x L x H) in mm 85 x 148.5 x 130 Weight 1000 g or less Housing materials Aluminium, PBT Max. number of modules 8 Max. number of digital inputs 128 Max. number of digital outputs 64 (independent of solenoid valves) Electrical Internal current consumption at 24 VDC (Via US1) 300 mA or less 250
Sets output ratio of cooling to heating to compensate difference of gain between them. 10 to 999% 6 Heating/Cooling Others (1%) 300 Ratio 10.2 Product alarm codes Level 1: Used in normal operation e.g. setting Sets the temp. range for judgment of overload (accompanying abnormal output alarm ERR15).
Hysteresis 4 Variable Protection Short circuit protection -66No.PF-OMS0002-B Model PFMC7501 PFMC7102 PFMC7202 Output type Voltage output: 1 to 5 V, Current output: 4 to 20 mA (Refer to analogue output graph) Voltage output Output impedance approx. 1 k Analogue output 5 Impedance Maximum load impedance: 600 at 24 VDC Current output 300 at 12 VDC Minimum load impedance: 50 Response time
It is possible to mount an auto switch in the intermediate position, but the cylinder speed for the switch detection needs to be adjusted to 300 mm/sec. or less in accordance with the response time of the load relay, etc. 5. When operating multiple cylinders with the auto switch in parallel, separate the cylinders, maintaining a minimum separation distance of at least 40mm. 6.
Caution Standard length is 300 mm, but the following lengths are also available.
This assembly does not include special cable assembly for a pressure switch with energy saving function. (6) Connector assembly ZK2-LV W K A Valve type: J Valve type: K, R Lead wire length Applicable valve type Nil 300 mm Valve type K, R W (With supply valve and release valve) 6 600 mm 10 1000 mm 20 2000 mm S Valve type J (Supply valve only) 30 3000 mm (7) One-touch fitting assembly (Purchasing
ZK2-OM00201 (7) Connector assembly ZK2 LV W K A Valve type: J Valve type: K, R Applicable valve type Lead wire length Nil 300 mm Valve type K, R 6 600 mm W (With supply valve and release valve) 10 1000 mm 20 2000 mm S Valve type J (Supply valve only) 30 3000 mm (8) One-touch fitting assembly (Purchasing order is available in units of 10 pieces.)
It is possible to mount an auto switch in the intermediate position, but the cylinder speed for the switch detection needs to be adjusted to 300 mm/sec. or less in accordance with the response time of the load relay, etc. 5. When mounting an auto switch on the driving cylinder side (on top of the cylinder), avoid interference of the auto switch with the workpiece.
It is possible to mount an auto switch in the intermediate position, but the cylinder speed for the switch detection needs to be adjusted to 300 mm/sec. or less in accordance with the response time of the load relay, etc. 5. When operating multiple cylinders with the auto switch in parallel, separate the cylinders, maintaining a minimum separation distance of at least 40 mm. 3.
The PE line of the power supply cable Indicated content : (1%) 300 Ratio #1 Temperature detected by internal ERR11 WRN temp. sensor PV < 31.6 C #1 SV < 30.0 C MODE Normal Sets the temp. range for judgment of overload (accompanying abnormal output alarm ERR15). #2 Temperature detected by external 0.1 to 9.9 7 Overload Judging is available for grounding.
. -14No.PS-OMR0002-K 2 About this product Specification Specifications (ISA3) Model ISA3-F ISA3-G ISA3-H Applicable fluid Dry air (Filtered through a 5 m filter) Rated distance range 0.01 to 0.03 mm 0.02 to 0.15 mm 0.05 to 0.30 mm Displayable/Settable range (Distance reference) 1 0 to 60 2 10 to 300 2 30 to 500 2 Minimum display resolution (Distance reference) 1 1 Rated pressure range 100
Description EX245-SPN1A EX245-SPN2A EX245-SPN3A General Dimensions (W x L x H) in mm 85 x 127.5 x 89.5 85 x 147.7 x 89.5 Weight 465 g 540 g Housing materials PBT Maximum number of modules 8 Maximum number of digital inputs 128 Maximum number of digital outputs 64 (independent of solenoid valves) Maximum number of IO-Link ports 32 Electrical Internal current consumption at 24 V DC (Via US1) 300
. + = 4 . 1 = a V V 2 V m M E k 2 Ek: Kinetic energy (J) M : Mass of object being transported (kg) m : Mass of moving parts of cylinder (kg) V: Maximum speed (m/s) Va: Average speed (m/s) Mass of moving parts of cylinder (kg) Bore size Standard stroke (mm) (mm) model 20 25 30 40 50 75 100 125 150 175 200 250 300 350 MLGPM20 0.40 0.42 0.45 0.47 0.59 0.65 0.71 0.77 0.83 0.89 1.08 1.20 1.31