Maximum 30 V (NPN only), 80 mA, Residual voltage 1 V or less See the operation manual for information on how to set and on handling precautions. Output -43 Output -65 DC (+) DC (+) (Brown) (Brown) N.C.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2.3 2.3 3-6.3 3-6.3 ZSP 23 20 26 23 20 26 30 29 10 30 29 10 ISA2 77 77 99 99 IS 126 126 R 3/8 R 3/8 ZSM PF2 IF Dripproof type ISG210 to 291-030 (Without hysteresis scale plate) ISG210 to 231-031 (With hysteresis scale plate) Data Hysteresis adjusting
ZS-20-5 A-501 pc. 19 NPN open collector 1 output w/analog output, 200 degrees adjustment 3 m 30 5 m 50 55 PNP open collector 1 output w/o analog output, 200 degrees adjustment 16-6-2 3 Compact Pressure Switch Series ZSE1/ISE1 Specifications ZSE1 For vacuum 0 to 101 kPa ISE1L For low pressure 0 to 100 kPa ISE1 For high pressure 0 to 1 MPa 1.5 MPa Air/Non-corrosive, non-flammable gas 12 to
Output specifications 15 NPN open collector 30 V, 80 mA 55 PNP open collector 80 mA With Connector/How to Order Without lead wire (Connector 1 pc., Socket 3 pcs.) ZS-10-A With lead wire ZS-10-5ANote) When ordering switch with 5 m long lead wire, indicate both part numbers. Lead wire length Caution 0.6 m Nil Ex.) ZSE2-01-15CN1 pc. ZS-10-5 A-501 pc.
Hysteresis 0.5 kPa Internal orifice 0.5 0.8 Supply voltage 12 to 24 VDC (Ripple 10% or less) Output type NPN open collector 30 V, 80 mA Indicator light ON: When output is ON.
Wide selection of port size and variations LVA LVH Threaded type (6A to 50A) Flange type (32F to 80F) LVD LVQ LQ LVN Low water hammer TI/ TIL PA Max.1.2 MPa PAX PB In the case of VNC211A (N.C. 0.5 MPa) Peak pressure when valve is closed (MPa) Large valve capacity Av factor 3.0 x 10-5 to 160 x 10-5 (VNC1 to VNC7) Cv factor 49 to 100 (VNC8 to VNC9) Fluid speed (m/s) Conditions: Piping length/30
Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
30 35 23 23 25 72 86 114 33 37 55 1 1 1 2 17-3-78 9 The VX series will be revised shortly.
AMJ 30 0003 2R ZR ZM Body size Pressure gauge position 30 3/8 None Bracket Nil ZH 40 1/2 B Option 50 3/4 ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Drain cock Nil Metal bowl 2 ZL Thread type Port size Nylon bowl 6 Drain guide (Rc 1/4) 02 1/4 Nil J Rc ZY 03
holes) 17 3 (For solenoid valve) M3 X 0.5 2.5 (Pilot port) A 11 17.5 1.5 21 27 30 28.5 P R 1 (Bleed port) 13 5 8.6 10 (P, A, R port) 3-M5 X 0.8 23 3.3-2 3 Port Air Operated Valve Series SYJA500/700 Model Valve model Actuation Port size Weight (g) Pilot port size Effective area (mm2) (Cv) SYJA512-M5 N.C. 3.6 (0.2) 45 Body ported M5 X 0.8 SYJA522-M5 N.O.
Low frequency operation Valves should be switched at least once every 30 days to prevent malfunction. (Use caution regarding the air supply.) 4. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.
AXT661-14ALead wire length VZ AXT661-13ALatching VQZ100 VQZ100-GS-2 300mm 600mm 1000mm 2000mm 3000mm VQZ200 6 10 20 30 VQZ200-GS-2 VT DC (-COM) VQZ300 VQZ300-GS-2 AXT661-13ANLatching Note) Above part number consists of a 10 pcs. units with one gasket and two screws. Orders are accepted in 10 pcs. units.
Filtration 30 m ZQ107 0.7 ZQ110 1.0 13-9-1 2 Compact Vacuum Ejector Series ZQ How to Order ZQ1 07 5 D31 1U K1 L C Ejector unit Nozzle nominal size Check valve 05 07 10 Nil K None With check valve 0.5 0.7 1.0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Note) The