0 0 V R [CR] + 0 1 2 3 4 5 (10 ) 28 - # 0 0 D R [CR] No.
Step Data Step No. 7.4 19 No.SFOD-OMT0009CN-B 3.7 JOG (1) ON ON (SVRE ON ) View(V) Status SVRE ON SVRE ON 20 20 No.SFOD-OMT0009CN-B (2) View(V) Teaching () SETON ONSETON 21 No.SFOD-OMT0009CN-B (3) JOG JOGInching JOG +/(a)JOG +/-+(b) +/-+ JOG 22 No.SFOD-OMT0009CN-B 3.8 View(V) (Test Drive) , (1) No.
It is possible to display parameters and step data as shown below. (1) Select the actuator Select "View(V)" at the top of the main window, and check the parameters. The Parameter window will be displayed. Select the "Actuator selection" button. The Actuator selection window will be displayed. -16No.
Applicable cable of the power supply connector Cable cross section Single wire, stranded wire 0.2 mm2 to 2.5 mm2/AWG24 to 12 Power supply connector for solenoid valve Terminal Wire colour Connection 24 V For solenoid valve +24 V 0 V For solenoid valve 0 V Note Wiring should be carried out with the power supply turned off.
It is possible to display parameters and step data as shown below. (1) Select the actuator Select "View(V)" at the top of the main window, and check the parameters. The Parameter window will be displayed.Select the "Actuator selection" button. The Actuator selection window will be displayed. -14No.
The connector for the power supply ( ) that is used to supply the power for 2 Socket for the power supply (PWR(V)) the solenoid valves.
Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.
Bore size(mm) Auto switch model 20 50 40 32 25 D-M9(V) D-M9W(V) D-A9(V) Note 1) Note 1) Note 1) Note 1) Note 1) BMA3-020 BMA3-025 BMA3-032 BMA3-040 BMA3-050 (A set of a,b,c,d) (A set of a,b,c,d) (A set of a,b,c,d) (A set of a,b,c,d) (A set of a,b,c,d) Note 2) D-M9A(V) BMA3-020S BMA3-025S BMA3-032S BMA3-040S BMA3-050S (A set of b,c,d,e) (A set of b,c,d,e) (A set of b,c,d,e) (A set of b,c,d
Contents Bore size (mm) R: NBR V: FKM R: NBR V: FKM R: NBR V: FKM R: NBR V: FKM R: NBR R: NBR !0 Piston seal CQ2B20V-PS CQ2B20R-PS 20 25 32 40 50 63 80 100 CQ2B20R-PS CQ2B25R-PS CQ2B32R-PS CQ2B40R-PS CQ2B50R-PS CQ2B63R-PS CQ2B80R-PS CQ2B100R-PS CQ2B20V-PS CQ2B25V-PS CQ2B32V-PS CQ2B40V-PS CQ2B50V-PS CQ2B63V-PS CQ2B80V-PS CQ2B100V-PS CQ2B25V-PS CQ2B25R-PS !
Material Case Note 1 Stainless steel 316 Electrolytic polishing (Interior/Exterior) V-clamp 2 Stainless steel 304 Holder 1 3 Polyester Holder 2 4 Filter medium 5 Element PTFE Seal 6 FKM V-seal 7 300 SFA100/200/300 Series Clean Gas Filter: Cartridge Type/Disc Type Flow Rate Characteristics Fluid: Compressed air Inlet temperature: 20C Dimensions SFA100/101, SFA200/201, SFA300/301 SFA10 Inlet
The maximum detectable piston speed is: Operating current of load (OFF condition) > Leakage current Auto switch operating range (mm) _ Load operating time (ms) V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3-wire switch if this specification will not be satisfied.
When requiring different port size, contact SMC. 02 Symbol No. of stations Type N 2 stations V 10 10 stations Manifold Optional Parts Option Body size Assembly part no. Attached parts 1 4 3 8 1 2 1 4 3 8 1 2 Blank plate XT015-4A XT016-5A XT038N-4A AXT394A AXT393A AXT396A Gasket, Bolt Interface speed control Gasket, Bolt Indicate valve and option number with the manifold base number.
When requiring different port size, contact SMC. 02 Symbol No. of stations Type N 2 stations V 10 10 stations Manifold Optional Parts Option Body size Assembly part no. Attached parts 1 4 3 8 1 2 1 4 3 8 1 2 Blank plate XT015-4A XT016-5A XT038N-4A AXT394A AXT393A AXT396A Gasket, Bolt Interface speed control Gasket, Bolt Indicate valve and option number with the manifold base number.