SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2A80-150DCZ-M9B"

Indicator light Load voltage Lead wire length (m) 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Applicable load connector Auto switch model Wiring (output) Special function Type Electrical entry Pre-wired None (N) AC DC Perpendicular In-line M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV1 M9N M9P M9B H7C G39 K39 M9NW M9PW M9BW M9NA1 3-wire (NPN) 5 V, 12 V IC circuit Grommet 3-wire (PNP) Reed auto switch Solid state

Indicator light Lead wire length (m) 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Load voltage Auto switch model Type Electrical entry Wiring (output) Special function Perpendicular In-line Applicable load Pre-wired None (N) AC DC connector M9N M9P M9B M9NV M9PV M9BV J79C M9NWV M9PWV M9BWV M9NAV1 3-wire (NPN) 5 V, 12 V IC circuit Grommet 3-wire (PNP) Reed auto switch Solid state auto switch 2-wire 12 V Connector

Prewired connector Indicator light Lead wire length (m) Load voltage Port on the right, cushion valve on top Special function Type Electrical entry Wiring (output) Applicable load Auto switch model 0.5 (Nil) 3 (L) 5 (Z) 1 (M) AC DC D M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire (NPN) IC circuit 5 V, 12 V Reed auto switch Solid state auto switch 3-wire (PNP) 2-wire 24 V Port on the right, cushion

Load voltage Lead wire length (m) 0.5 (Nil) 3 (L) 1 (M) 5 (Z) None (N) Applicable load Auto switch model Indicator light Wiring (Output) Pre-wired connector Type Special function Electrical entry Band mounting (6, 10, 16) Rail mounting (10, 16) Perpendicular In-line DC AC F79 F7P J79 F79W F7PW J79W F7BA F79F F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV M9N M9P M9B H7C M9NW M9PW

Auto switch model Lead wire (m) Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Indicator light Electrical entry Type Special function Perpendicular In-line 0.5 (Nil) 3 (L) 5 (Z) 1 (M) 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9N M9P M9B M9NW M9PW M9BW M9NA 5 V, 12 V IC

Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Nil Built-in magnet No D With auto switch (Built-in magnet) 10 C D M 2 L 40 150 A F Z M9BW 21 C D M 2 L 40 150 A Z M9BW Mounting Basic (Double-side bossed) Axial foot Rod flange Head flange Boss-cut, Basic Boss-cut, Rod flange B L F G BZ FZ Solid state Auto switch M9B, M9BW Reed

N A Nil Built-in magnet Clean series 10 11 Relief type Vacuum suction type No D With auto switch (Built-in magnet) Bore size (mm) 10 C D G 1 B N 40 150 Z M9BW 21 C D G 1 B N 40 150 Z M9BW Mounting Cylinder stroke (mm) B Auto switch Number of auto switches Basic Axial foot Rod flange Head flange Rod end thread Copper, fluorine and silicone-free + Low particle generation L F G Solid state M9B

Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Nil Built-in magnet No D With auto switch (Built-in magnet) 10 C D M 2 L 40 150 A F Z M9BW 21 C D M 2 L 40 150 A Z M9BW Mounting Basic (Double-side bossed) Axial foot Rod flange Head flange Boss-cut, Basic Boss-cut, Rod flange B L F G BZ FZ Solid state Auto switch M9B, M9BW Reed

Indicator light Yes Auto switch model Lead wire length (m) Note 1) Applicable load Applicable model Load voltage Type Special function Electrical entry Wiring (Output) 0.5 Nil 3 (L) 5 Note 2) DC Perpendicular 10 16 20 25 In-line AC (Z) Solid state auto switch M9NV F8N M9PV F8P M9BV F8B M9N M9P M9B 3-wire (NPN) 5 V 12 V IC circuit Relay PLC 3-wire (PNP) 24 V Grommet 2-wire 12 V Note 1

Lead wire length (m) Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Relay, PLC Yes 100 V 24 V M9N 12 V 3-wire (NPN) Solid state auto switch Grommet Yes Relay, PLC 24 V 2-wire 12 V M9B Lead wire length symbols 0.5

Lead wire length (m) Load voltage 5 (Z) Applicable load Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 1 (M) 3 (L) AC DC 12 V In-line A93 M9N M9B Reed auto switch 24 V 2-wire 100 V 12 V Relay, PLC Grommet Yes 3-wire (NPN) Solid state auto switch 24 V Relay, PLC Grommet Yes 12 V 2-wire PLC: Programmable Logic

Lead wire length (m) Load voltage Auto switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V Reed auto switch 2-wire Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols: 0.5

Load voltage Auto switch model Perpendicular Lead wire length (m) 0.5 (Nil) Indicator light Wiring (Output) Applicable load Pre-wired connector 1 (M) Type Special function Electrical entry In-line 3 (L) 5 (Z) None (N) AC DC 32 to 100 20, 25 40 to 100 20, 25 32 M9NV M9PV M9BV M9N M9P M9B 5 V, 12 V 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 2-wire 12V 5 V, 12 V 12 V 5 V, 12 V 12 V Solid state